AUTOMATION
CONTROLS

Search
Discontinued
Products



UELC500 | Control Unit ELC500


Control Unit ELC500

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


  • To Be Discontinued
  • Last time buySeptember 30, 2024
Product Number UELC500
Part Number UELC500
Product name Control Unit ELC500
  • Substitute -
  • Sub Prod No. -
  • Sub Part No. -
  • Remark Sorry, no suggested alternative products.

As of April 26, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number UELC500
Part Number UELC500

Main unit specifications

Item Specifications
Rated operating voltage 24 V DC
Current consumption 300 mA or less
Note : Regarding system consumption current, see the User’s Manual for ELC500 Control Unit.
Ambient temperature 0 to +55 ℃ +32 to+131 ℉
Ambient humidity 10 to 95% RH(at +25 ℃ +77 ℉, no dew condensation allowed)
Serial communication Ethernet: 1 port, RS-232C: 1 port, RS-485 / 422: 2 ports
Compatible regulations Low Voltage Directive, EMC Directive, RoHS Directive

External memory specifications

Item Specifications
Supported media SD memory card
Compatible format Compatible with SD / SDHC standards (FAT16 and FAT32 only)
Capacity 2 to 32 GB
Speed class Class 2 to Class 10
Remark Notes :
1) If a (momentary) power outage occurs during writing, data can become corrupted. Use of UPS (Uninterruptible Power Supply) is recommended.
2) Use of Panasonic's industrial SD memory card (SLC memory card) is recommended. For the handling of SD memory card, see the User's Manual for ELC500 Control Unit.

Main specifications

Item Specifications
Communication(Downstream communication) • Ethernet: 1 port [supported protocols: MEWTOCOL-COM, Modbus TCP; number of nodes: 197 units; number of simultaneous connections: 20]
• RS-232C: 1 port [supported protocols: MEWTOCOL-COM, Modbus RTU, general-purpose communication]
• RS-485 / 422: 2 ports [supported protocols: MEWTOCOL-COM, Modbus RTU, PLC link, general-purpose communication]
Note : Ethernet is a registered trademark of Fuji Xerox Co., Ltd. and Xerox Corporation in the U.S. Modbus protocol is a communication protocol developed by Modicon Inc. for use with programmable logic controllers (PLCs).
Data collection (logging) function • Stored data: Instantaneous values, differential values
• Data storage location, storage format: SD / SDHC memory card, CSV file format
• Maximum number of registerable points: 512 points/16 files (Up to 16 files can be registered. Up to 128 points can be registered in 1 file.)
• Number of storable files: 100 files
Demand monitoring function • Demand type: Constant-cycle (15 / 30 / 60 min) demand; demand cycle: 5 sec (high speed)/min, IEC demand (Note 1) (demand / interval time span: 1 to 60 min)
• Total number of demand monitoring target units: 50 units
• Number of registerable I/O control devices / control patterns: 16 points / alarm-linked control, startup control, cyclic control (ON/OFF control for all) (Note 2)
Notes :
1) Demand in compliance with IEC 61557-12, “Performance measuring and monitoring devices (PMD)”
2) Use ECOnect® series remote I/O units (UENU2D4R12).
Network function • Communication protocols: TCP/IP, UDP/IP
• Application protocols: SMTP (SMTP AUTH supported), FTP (client / server), SNTP, DHCP, DNS, HTTP (server)
Email transmission function • Number of registerable points: 16 points
• Subject title: 64 half-width characters (32 full-width characters), Message: 256 half-width characters (128 full-width characters)
Others • Web server function: Custom Web region, 8 MB (Control Web Creator is required), number of simultaneous sessions: 16
• Extension function: Addition of FP7 (PLC) units enables acquisition of information such as I/O signals, analog data and temperature data. Maximum of 8 units (Note)
• Program function: 32-k steps Programming is possible when Control FPWIN Pro7 is used.
(Note) The number of connectable units is limited. For details, refer to the ELC500 Control Unit Specifications or manual.

Return to top

Accessories (Option)

no_image
Product Number AFP7END
Part Number AFP7END
Product name FP7 End unit
no_image
Product Number AFPG805
Part Number AFPG805
Product name Power cable
Backup battery
Product Number AFPX-BATT
Part Number AFPX-BATT
Product backup battery
Product name Backup battery


Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)