【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.

AUTOMATION
CONTROLS

Search
Discontinued
Products



AC Fan Motor 80 x 25t(ASEP8) (Discontinued Products)

Specifications

RATING

Lead wire type, Standard speed ASEP80211

Rated voltage (V) Frequency (Hz) Input power
(W)
max/AVE
Rated current
(mA)
max/AVE
Locked current
(mA)
max/AVE
Rotation speed
(min-1)
min/AVE
Max. air flow
(m3/min)
min/AVE
Max. static
pressure
(Pa)
min/AVE
Noise
(dB)
max/AVE
Operating
voltage range
(V) (%)
Weight
(kg)
100 50 8.8/8.0 130/110 150/120 2,500/2,700 0.52/0.57 34.0/39.0 29.0/24.0
(34.0/29.0)
±10 0.24
60 7.15/6.5 110/90 140/110 3,000/3,200 0.63/0.68 48.0/55.0 36.0/31.0
(41.0/36.0)

Note: 1Values above without designations are averages.
Note: 2Noise levels are based on measurements taken at a distance of 1 m from the front of the fan.

Lead wire type, Standard speed ASEP80212

Rated voltage (V) Frequency (Hz) Input power
(W)
max/AVE
Rated current
(mA)
max/AVE
Locked current
(mA)
max/AVE
Rotation speed
(min-1)
min/AVE
Max. air flow
(m3/min)
min/AVE
Max. static
pressure
(Pa)
min/AVE
Noise
(dB)
max/AVE
Operating
voltage range
(V) (%)
Weight
(kg)
115 50 8.8/8.0 110/93 130/100 2,500/2,700 0.52/0.57 34.0/39.0 29.0/24.0
(34.0/29.0)
±10 0.24
60 7.15/6.5 90/77 120/90 3,000/3,200 0.63/0.68 48.0/55.0 36.0/31.0
(41.0/36.0)

Note: 1Values above without designations are averages.
Note: 2Noise levels are based on measurements taken at a distance of 1 m from the front of the fan.

SPECIFICATIONS

Ambient temperature -10℃ to +60℃ +14℉ to +140℉
Ambient humidity 15 to 85%RH
Storage temperature -20℃ to +70℃ -4℉ to +158℉
Breakdown voltage 1,500 V AC for 1 min. (between charging section and frame)
Insulation resistance Min. 100MΩ (at 500 V DC megger)
(between charging section and frame)
Insulation class UL:A class
Vibration resistance Frequency 10 to 55Hz
Double amplitude width 0.75mm
Applied direction X, Y and Z directions
Applied time 10 min. in each direction
Protection Impedance protected
Mean life 100,000 hours at 25 ℃
(Life time when continuously energized by applying the rated voltage
Current value: + 15% or more
Rotation speed: -15% or less)

DATA (Airflow - Static pressure Characteristic Curve)

MATERIALS USED

Frame aluminum alloy die-casting
Propeller plastic
Bearings ball bearings
Lead wires UL3266 and AWG22
Label 100 V class...black base

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)