【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.

AUTOMATION
CONTROLS

Search
Discontinued
Products



LT4H-W Digital Timers(DIN 48) (Discontinued Products)

Rating/ Performance

Item Ralay output type Transistor output type
AC type DC type AC type DC type
Rating Operating voltage 100 to 240 V AC, 24 V AC 12 to 24 V DC, 24 V AC 100 to 240V AC, 24 V AC 12 to 24 V DC, 24 V AC
Frequency 50/60 Hz common -
50/60 Hz common -
Power consumption Max. 10 V A Max. 3 W Max. 10 V A Max. 3 W
Control capacity (resistive) 5 A, 250 V AC (Resistive load) 100 mA, 30 V DC
Time range 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 999.9 min. 99 h 59 min, 999.9 h (selected by DIP switch)
Time counting direction Addition (UP)/Subtraction (DOWN) (2 directions selectable by DIP switch)
Operation mode Pulse input: Delayed one shot, OFF-start flicker or ON-start flicker Integrating input: Delayed one shot, OFF-start flicker or ON-start flicker
Signal/Reset/Stop input Min. input signal width: 1 ms, 20 ms (2 directions by selected by DIP switch)
Lock input Min. input signal width: 20 ms
Input signal Open collector input Input impedance: Max. 1 kohm; Residual voltage: Max. 2V Open impedance: 100 kohm or less, Max. energized voltage: 40 V DC
Indication 7-segment LCD, Elapsed value (backlight red LED), Setting value (backlight yellow LED)
Power failure memory method EEP-ROM (Min. 105overwriting)
Time accuracy (max.) Operating time fluctuation ±(0.005%+50 ms) in case of power on start ±(0.005%+20 ms) in case of reset or input signal start [Operating voltage: 85 to 110% Temperature: -10 to +55°C +14 to +131 ° F Min. input signal width: 1ms]
Temperature error
Voltage error
Setting error
Contact Contact arrangement Timed-out 1 Form C Timed-out 1 Form A (Open collector)
Initial contact resistance 100 mohm (at 1 A 6 V DC) -
Contact material Ag alloy/Au flash -
Life Mechanical 2.0 × 107ope. (Except for switch operation parts) -
Electrical 1.0 × 105ope. (At rated control voltage) 1.0 × 107ope. (At rated control voltage)
Electrical Operating voltage range 85 to 110% of rated operating voltage
Initial breakdown voltage 2, 000 Vrms for 1 min: Between live and dead metal parts (11-pin) 2, 000 Vrms for 1 min: Between input and output 1, 000 Vrms for 1 min: Between contacts 2, 000 Vrms for 1 min: Between live and dead metal parts (Pin type) 2, 000 Vrms for 1 min: Between input and output
Initial insulation resistance (At 500 V DC) Min. 100 Mohm: Between live and dead metal parts Between input and output Between contacts Min. 100 Mohm: Between live and dead metal parts Between input and output
Operating voltage reset time Max. 0.5 s
Temperature rise Max 65°C (under the flow of nominal operating current at nominal voltage)
Mechanical Vibration resistance Functional 10 to 55 Hz: 1 cycle/ min single amplitude of 0.35 mm .014 inch (10 min on 3 axes)
Destructive 10 to 55 Hz: 1 cycle/ min single amplitude of 0.75 mm .030 inch (1 h on 3 axes)
Shock resistance Functional Min. 98 m 321.522 ft./s2(4 times on 3 axes)
Destructive Min. 294 m 964.567 ft./s2(5 times on 3 axes)
Operating conditions Ambient temperature -10°C to 55°C + 14 ° F to + 131 ° F
Ambient humidity Max. 85% RH
Air pressure 860 to 1, 060 h Pa
Ripple rate -
20% or less -
20% or less
Connection 8-pin/11-pin/screw terminal
Protective construction IP66 (front panel with rubber gasket)

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)