Item | Unit |
Data range | |
---|---|---|---|
Instantaneous electrical power |
kW |
0.00 to 999999.99 | |
Integrated electrical power |
kWh |
0.00 to 9999999.9 | |
Current |
L1 (CT1) phase current |
A |
0.0 to 6000 |
L2 (CT2) phase current |
A |
0.0 to 6000 | |
Voltage |
Voltage between 1-2 |
V |
0.0 to 9999 |
Voltage between 2-3 |
V |
0.0 to 9999 | |
Electricity charge (Note) |
0.00 to 99999999 |
Note : Eco-POWER METER is designed chiefly to manage saving energy. It is neither intended nor can it be legally used for billing.
Item | Specifications | |
---|---|---|
Rated operating voltage |
100 to 120/200 to 240V AC | |
Rated frequency |
50/60 Hz common | |
Rated power consumption |
6 VA (240 V AC at +25 ℃ +77 ℉) | |
Allowable operating voltage range |
85 to 132/170 to 264V AC (85% to 110% of rated operating voltage) | |
Allowable momentary power-off time |
10 ms | |
Ambient temperature |
-10℃ to +50℃ +14 ℉ to +122 ℉ (-25℃ to +70℃ -13 ℉ to +158 ℉ at storage) |
|
Ambient humidity |
30 to 85%RH (at +20℃ +68 ℉ non-condensing) | |
Breakdown voltage (initial) |
Between the isolated circuits: 2000 V for 1min | ・ Insulated circuit [between (1) and (2), (2) and (3), (1) and (3)] (1) Power terminal [1 (R), 2 (N and S) and 3 (T)] CT input terminal [CT1 (+, -), CT2 (+, -)] - all terminals (2) RS485 terminal (+, -, E) - all terminals (3) Pulse output terminal (+, -) - all terminals ・ Outer edge (case) - all terminals |
Insulation resistance (initial) |
Between the isolated circuits: 100 MΩ or more (measured with 500 V DC) |
|
Vibration resistance |
10 to 55 Hz (1cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes) | |
Shock resistance |
Min. 294 m/s2 (5 times on 3 axes) | |
Display method |
8-digit, 7-segment LED | |
Power failure memory method |
EEP-ROM (Over 100,000 overwrites) | |
Weight |
100 g approx. |
Item | Specifications | |
---|---|---|
Input voltage | Rating | Single-phase two-wire system: 100 to 120/200 to 240 V AC (common use) Single-phase three-wire system: 100 to 120 V AC Three-phase three-wire system: 100 to 240 V AC |
Allowable measuring voltage | 85% to 110% of rated operating voltage | |
VT ratio | 1.00 to 99.99 [External voltage transformer (VT) is required.] | |
Input current | Rating of primary side | 5 A/50 A/100 A/250 A/400 A (when using dedicated CT) 1 to 4000 A (when using secondary 5A CT) |
Cut-off current | 1.0 to 50.0%F.S | |
Accuracy (without error in CT and VT) |
Basic accuracy | Instantaneous electric power / Integrated electric power / Electricity charge |
Within ± (2.0 % F.S. + 1 digit) (at +20 ℃ +68 ℉, rated input, rated frequency, power factor 1) In case of 5 A CT mode, within ± (2.5 % F.S. + 1 digit) *Accuracy coverage: 5 to 100 % of rated current |
||
Current | ||
Within ± (1.0 % F.S. + 1 digit) In case of 5 A CT mode, within ± (2.5 % F.S. + 1 digit) (at +20 ℃ +68 ℉ rated input, rated frequency, power factor 1) *Accuracy coverage: 5 to 100 % of rated current |
||
Voltage | ||
Within ± (1.0 % F.S. + 1 digit) (at +20 ℃ +68 ℉ rated input, rated frequency, power factor 1) |
||
Temperature characteristics | Within ± (1.0 % F.S. + 1 digit) In case of 5 A CT mode, within ± (1.5 % F.S. + 1 digit) (Range of -10 to +50 ℃ +14 to +122 ℉, rated input, power factor 1) |
|
Frequency characteristics | Within ± (1.0 % F.S. + 1 digit) In case of 5 A CT mode, within ± (1.5 % F.S. + 1 digit) (Frequency change ± 5 % based on rated frequency, rated input, power factor 1) |
Item | Specifications |
---|---|
Number of output point | 1 point |
Insulation method | Optical coupler |
Output type | Open collector |
Output capacity | 100mA 30V DC |
Pulse width | approx. 100ms |
ON state voltage drop | 1.5V or less |
OFF state leakage current | 100μA or less |
Pulse output unit | 0.001/0.01/0.1/1/10/100kWh/ Power alarm(AL-P)/Current alarm(AL-C) /Stand-by alarm (AL-S) (Selectable with setting mode) |
* We recommend the setting of minimum unit for pulse output for measurement shown as below.
Output pulse: 4 pulse or less per 1sec.
-How to calculate-
(Unit for pulse output: PL-P) > (Max. measurement power [kW])/(3600[s]×4 [pulse/s])
Note :1) Improper unit setting may cause miss counting.
Note :2) If the OFF time is too short, there is a possibility of counting errors.
Item | Specifications | |
---|---|---|
Interface | Conforming to RS-485 | |
Protocol | MEWTOCOL/MODBUS(RTU) (selectable with setting mode) | |
Isolation status | Isolated with the internal circuit | |
Number of connected units | 99 (max.) (Note2)(Note3) | |
Transmission distance | 1200m (max.) (Note1) | |
Transmission speed | 38400/19200/9600/4800/2400bps (selectable with setting mode) | |
Transmission Format | Data length | 8bit/7bit (selectable with setting mode) (Note4) |
Parity | Not available / Odd number / Even number (selectable with setting mode) | |
Stop bit | 1bit(fixed) | |
Communication method | Half-duplex | |
Synchronous system | Synchronous communication method | |
Transmission line | Twisted-pair cable with shield or VCTF | |
Communication mode | 1 : N communication | |
Ending resistance | approx. 120Ω(built-in) (Terminal (E) and terminal (-) is shorted when ending.) |
Notes:
1) Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
2) For RS485 converter on the computer side, we recommend SI-35 and SI-35USB (from LINE EYE Co., Ltd.).
3) When using SI-35, SI-35USB or PLC from our company (which can be connected up to 99 units), up to 99 Eco-POWER METER can be connected. In case using this system with the other devices, up to 31 Eco-POWER METER can be connected.
4) With MODBUS (RTU) protocol, it works only with 8bit.
Item | Clamp-on typ | ||||
---|---|---|---|---|---|
AKW4801B AKW4801C |
AKW4802B AKW4802C |
AKW4803B AKW4803C |
AKW4804B AKW4804C |
AKW4808B AKW4808C |
|
CE marking directive compliance | Low Voltage Directive, RoHS Directive | ||||
Primary side rated current | 5A/50A | 100A | 250A | 400A | 600A |
Secondary side rated current | 1.67mA/16.7mA | 33.3mA | 125mA | 200mA | 200mA |
Winding (Turn) | 3000 | 3000 | 2000 | 2000 | 3000 |
Ratio error | ±2.0%F.S. | ||||
Through hole | ø10 ø0.39 | ø16 ø0.63 | ø24 ø0.94 | ø36 ø1.42 | ø36 ø1.42 |
Breakdown voltage (initial) | 1000V AC/1min (Between through hole and output lead wire) |
2000V AC/1min (Between through hole and output lead wire) |
|||
Insulation resistance (initial) | Min. 100 M Ω (at 500 V DC) (Between through hole and output lead wire) | ||||
Functional vibration resistance | 10 to 55 Hz (1 cycle / min), single amplitude: 0.15 mm 0.01 in (10 min on 3 axes) | ||||
Vibration resistance | 10 to 55 Hz (1 cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes) | ||||
Functional shock resistance | Min. 98m/s2(4 times on 3 axes) | ||||
Shock resistance | Min. 294m/s2(5 times on 3 axes) | ||||
Output protection level | ±7.5 V with clamp element | ±3.0V with clamp element | |||
Permissible clamping frequency | 100 times approx. | ||||
Ambient temperature range | -10 to +50℃ +14 to +122 ℉ (without frost and non-condensing) | ||||
Storage temperature | -20 to +60℃ -4 to +140 ℉ (without frost and non-condensing) | ||||
Ambient humidity | 35 to 85%RH(at +20℃ +68 ℉ non-condensing) | ||||
Dimensions (mm in) (W x H x D) |
23 x 40 x 26.5 0.08 x 0.13 x 0.09 |
30 x46.5 x 32 0.10 x 0.15 x 0.11 |
45 x65 x 34 0.15 x 0.21 x 0.11 |
57 x81 x 38 0.19 x 0.27 x 0.12 |
62.6 x93.3 x 40 0.21 x 0.31 x 0.13 |
Weight (Relay cable included) |
60 g approx. | 90 g approx. | 200 g approx. | 295 g approx. | 450 g approx. |
Item | Through type | |||
---|---|---|---|---|
AKW4506B AKW4506C |
AKW4507B AKW4507C |
AKW4508B AKW4508C |
||
CE marking directive compliance | Low Voltage Directive, RoHS Directive | |||
Primary side rated current | 50A/100A | 250A/400A | 600A | |
Secondary side rated current | 16.7mA/33.3mA | 125mA/200mA | 200mA | |
Winding (Turn) | 3000 | 2000 | 3000 | |
Ratio error | ±1.0%F.S. | |||
Through hole | ø17mm ø0.67 in | ø36mm ø1.42 in | ||
Breakdown voltage (initial) | 1000V AC/1min (Between through hole and output lead wire)) |
2000V AC/1min (Between through hole and output lead wire) |
||
Insulation resistance (initial) | Min. 100 MΩ (at 500 V DC megger) (Between through hole and output lead wire) | |||
Functional vibration resistance | 10 to 55 Hz (1 cycle / min), single amplitude: 0.15 mm 0.01 in (10 min on 3 axes) | |||
Vibration resistance | 10 to 55 Hz (1 cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes) | |||
Functional shock resistance | Min. 98 m/s2 (4 times on 3 axes) | |||
Shock resistance | Min. 294 m/s2 (5 times on 3 axes) | |||
Output protection level | ±7.5 V with clamp element | ±3.0 V with clamp element | ||
Permissible clamping frequency | - | |||
Ambient temperature range | –10 to +50 ℃ +14 to +122 ℉ (without frost and non-condensing) | |||
Storage temperature | –20 to +60 ℃ –4 to +140 ℉ (without frost and non-condensing) | |||
Ambient humidity | 35 to 80 % RH (at +20 ℃ +68 ℉non-condensing) | |||
Dimensions (mm in) (W x H x D) |
ø42 x 15 1.65 x 0.05 |
ø70 x19 2.76 x 0.06 |
ø70 x19 2.76 x 0.06 |
|
Weight (Relay cable included) |
70 g approx. | 200 g approx. | 215 g approx. |
Notes :
1) | Dedicated CT are dedicated for low voltage under 440 V AC system. They can not be used for high voltage circuit. |
---|---|
2) | In each type of Eco-POWER METER excluding AKW8115, KW9M and KW2M, a combination of commercially secondary side 5 A CTs and dedicated CTs for 5 A is used for measuring high voltage circuits; For details, confirm with each respective user's manual. |
3) | Since dedicated CTs cannot be used when measuring with AKW8115, KW9M and KW2M, please be careful and do not purchase a dedicated CT by mistake. |
4) | For the AKW8115, KW9M and KW2M, CT with a secondary side current 1 A or 5 A is recommended. Please confirm the specification beforehand. |
5) | Dedicated CT are not included with Eco-POWER METERs. |
6) | Each dedicated CT includes a 1 m 3.281 ft relay cable, respectively. |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)