AUTOMATION
CONTROLS

Search
Discontinued
Products



Amplifier Built-in / U-shaped Micro Photoelectric Sensor[Ultra-small / Cable type] PM-25

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

Mounting

  • The following conditions must be observed when using screws to mount the sensor unit.
Screw Spring washer Flat washer Tightening torque
M2 screw 1 pc. ø4.3 mm ø0.169 in
(small round washer)
0.15N・m
M3 screw 1 pc. ø6 mm ø0.236 in
(small round washer)
0.5N・m

<When using M2 screws for mounting>

<When using M3 screws for mounting>

When using the optional mounting screw set MS-M2, a spring washer is included.

  • In case the PM-25 series is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body.

Cable extension

  • Cable extension is possible up to an overall length of 100 m 328.084 ft with a 0.3 mm2, or more, cable. However, since a voltage drop shall occur due to the cable extension, ensure that the power supply voltage at the end of the cable attached to the sensor is within the rating.

Cable extension

But, when the overall cable length, including the cable attached to the sensor, is as given below, there is no need to confirm the voltage.

Conductor crosssection
area of extension cable
Total cable length
0.08 to 0.1mm2 Up to 5 m 16.404 ft
0.2mm2 Up to 10 m 32.808 ft
0.3mm2 Up to 20 m 65.617 ft

When using the product as an S-mark compatible product in Korea

  • The power supply cable and output cable connected to the product must be less than 10 m 32.808 ft.

Other

  • This device has been developed / produced for industrial use only.
  • Since the sensor is intended for use inside machines, no special countermeasures have been taken against extraneous light. Take care that extraneous light is not directly incident on the beam receiving section.

  • Do not use during the initial transient time (50 ms) after the power supply is switched on.
  • If the sensor is used in a place having excessive dust, periodically clean the emitting and receiving sections with a dry, soft cloth.
  • If there is a large surge generating equipment, such as, motor, solenoid, electromagnetic valve, etc., in the vicinity of the sensor, use a surge absorber on that equipment. Further, do not run the sensor cables along power lines and use a capacitor between +V and 0 V, if required. Use the sensor after confirming that the surge has been eliminated.
  • Note that the cable of PM-□25-R loses its flexibility when the ambient temperature decreases to about -10 ℃ +14 ℉.
  • The cable of PM-□25-R is a bending-resistant cable usable on a moving base. When the sensor is mounted on a moving base, secure the sensor cable joint at the unit in place so that stress is not applied to it.
  • When storing PM-□25-R, make sure that the cable does not come into contact with the sensing section or operation indicator.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE SEARCH FAQ

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

FAQ


Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)