Connector Built-in U-shaped Micro Photoelectric Sensor[Amplifier Built-in] PM-64 (Discontinued Products)

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
  • Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit.
    Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load.
    Faulty wiring may result in damage.

Mounting

  • When fixing the sensor with screws, use M3 screws and the tightening torque should be 0.5 N·m or less.
    Further, use small, round type plain washers (ø6 mm ø0.236 in).

Mounting

Wiring

Connection method

Connection method

<Connector>
Housing: PAP-04V-S
(Manufactured by J.S.T.
Mfg. Co., Ltd.)

  • Insert the connector attached cable CN-14A(-R)-C□ in the connector part of this product as shown in the left figure.

<Connector pin position>

Connector pin No. Terminal designation
(1) +V
(2) Output 1
(3) Output 2
(4) 0 V

Disconnection method

  • Pressing the projection of the connector attached cable, pull out the connector.
Note: Take care that if the cable is pulled out without pressing the projection, the cable may break.

Cable extension

  • Cable extension is possible up to an overall length of 100 m 328.084 ft with a 0.3 mm2, or more, cable.
    However, since a voltage drop shall occur due to the cable extension, ensure that the power supply voltage at the end of the cable attached to the sensor or at the sensor terminals is within the rating.

But, when the overall cable length, including the cable attached to the sensor, is as given below, there is no need to confirm the voltage.

Conductor crosssection
area of
extension cable
Total cable length
0.08 to 0.1 mm2 Up to 5 m 16.404 ft
0.2 mm2 Up to 10 m 32.808 ft
0.3 mm2 Up to 20 m 65.617 ft

Others

  • Since the sensor is intended for use inside machines, no special countermeasures have been taken against extraneous light.
    Take care that extraneous light is not directly incident on the beam receiving section.

  • Do not use during the initial transient time (50 ms) after the power supply is switched on.
  • If the sensor is used in a place having excessive dust, periodically clean the emitting and receiving sections with a dry, soft cloth.
  • If there is a large surge generating equipment, such as, motor, solenoid, electromagnetic valve, etc., in the vicinity of the sensor, use a surge absorber on that equipment.
    Further, do not run the sensor cables along power lines and use a capacitor between +V and 0 V, if required.
    Use the sensor after confirming that the surge has been eliminated.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)