【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.

AUTOMATION
CONTROLS

Search
Discontinued
Products



CC-Link Safety System Remote I/O Unit for Light Curtain SF-CL1T264T (Discontinued Products)

Specifications

Designation CC-Link Safety system I/O unit
with connectors for light curtain
Model No. SF-CL1T264T
Connectable light curtain SF4B series
Applicable standard IEC / EN 61508 (SIL 3), EN ISO 13849-1 (JIS B 9705-1) (Category 4, PLe), UL 508
Unit power
(Note 2)
Supply voltage 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption 140 mA or less (24 V DC, with all points ON)
Protective function Unit power overvoltage / overcurrent protection function
Fuse 0.8 A (Not replaceable)
Momentary power failure period 10ms or less
Input
specifications
No. of input points (Note 3) Input of light curtain: 2 points (with interference prevention function),
Input of terminal block: 6 points (input terminals: 12 points)
Insulation method Photocoupler
Rated input voltage 24 V DC
Rated input current 4.6 mA approx.
Operating voltage range 24 V DC ±10 % Ripple P-P 10 % or less
Max. simultaneous
input points
100 %
ON voltage / ON current 15 V DC or more / 2 mA or more
OFF voltage / OFF current 5 V DC or less / 0.5 mA or less
Input resistance 5.6 kΩ approx.
Input type Negative common
Response time OFF -> ON: 0.4 ms or less (at 24 V DC, excluding connecting device)
ON -> OFF: 0.4 ms or less (at 24 V DC, excluding connecting device)
Safety remote station
input response time
32 ms or less + filter-out time (1 ms, 5 ms, 10 ms, 20 ms, 50 ms)
Output
specifications
No. of output points 4 points (source + sink type), 2 points (source + source type)
Insulation method Photocoupler
Rated load voltage 24 V DC
Rated load voltage range 24 V DC ±10 % Ripple P-P 10 % or less
Max. load current 0.5 A / point
Inrush current 1.0 A (10 ms or less)
Leakage current 0.5 mA or less
Residual voltage 1.0 V DC or less
Protective function Output short-circuit protection function
Output type Source + sink type, Source + source type
Response time OFF -> ON: 0.4 ms or less (at 24 V DC)
ON -> OFF: 0.4 ms or less (at 24 V DC)
Safety remote station
input response time
32 ms or less
Surge protection Incorporated (Zener diode)
External power
supply
(For external
device)
(Note 3)
Voltage 24 V DC ±10 % Ripple P-P 10 % or less
Current 60 mA (24 V DC, with all points ON, excluding external load current)
Protective function External power supply overvoltage / overcurrent protection function
Fuse 8 A (Not replaceable)
Wiring method for common 16 input points / common, 4 output points / common (Terminal block 2-wire type)
Common current Max. 4 A (Total of inputs and outputs)
No. of stations occupied 1 station
No. of access to nonvolatile memory 1012 times
Safety refresh response processing 38 ms
Excess voltage category II
Pollution degree 2
Protection IP20
Ambient temperature 0 to +55 ℃ +32 to +131 (No dew condensation), Storage: -40 to +75 ℃ -40 to +167
Ambient humidity 5 to 95 % RH, Storage: 5 to 95 % RH
Dielectric withstand voltage 500V AC between all external DC terminals and ground, for 1 minute
Insulation resistance 10 MΩ or more between all external DC terminals and ground, by a 500 V DC insulation resistance tester
Vibration resistance / Shock resistance Conforming to JIS B 3502, IEC 61131-2
Material Enclosure: ABS
External connection system Terminal block, 2 crimp-style terminals or less
Cable 0.3 to 2.0 mm2
Applicable crimp-style terminal RAV1.25-3 (Conforming to JIS B 2805) (Applicalbe wire size: 0.3 to 1.25 mm2)
Weight Net weight: 0.7 kg approx.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature +20 ℃ +68 .
2) The power supply connected to this product must satisfy the following conditions:
1 SELV (Safety Extra Low Voltage) : Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
3) Total number of input points is 8 points, and use 2 points for control output (OSSD 1, 2) of 2 light curtains. Two inputs terminals are assigned for each input since dual wiring is supported.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)