Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Wire-Saving Systems > S-LINK V gateway controller for open network > Specifications
Discontinuation plan
|
|
Designation | S-LINK V gateway controller for EtherCAT | |
---|---|---|
Model No. | SL-VGU1-EC | |
Supply voltage | 24 V DC+10–5% | |
Current consumption | 300 mA or less (excluding error output load and power supply for driving I/O units) (Note 1) |
|
Allowable through current | 7A (Note 2) | |
S-LINK V side |
Transmission speed | A mode: 110 kbps, B mode: 27.5 kbps, C mode: 6.9 kbps |
Refresh time | A mode: 0.29 to 10.32 ms, B mode: 1.18 to 41.29 ms, C mode: 4.70 to 165.15 ms |
|
I/O points | Max. 512 points | |
Connected node No. | Max. 256 nodes | |
Transmission distance | A mode: 50 m 164 ft max., B mode: 200 m 656 ft max., C mode: 800 m 2,625 ft max. | |
Total wiring length | A mode: 100 m 328 ft or less, B mode: 400 m 1,312 ft or less, C mode: 1,600 m 5,249 ft or less | |
Transmission cable | Exclusive 4-core flat cable (0.5 mm2) or conductor cross-section area 0.3 to 2.0 mm2 4-core VCTF cable (without shield) (Note 3) |
|
I/O combination | I/O settable in increments of 32 points | |
Error output | NPN open-collector transistor | |
EtherCAT communication side |
Protocol | CoE PDO communication, SDO communication |
Compliance | IEEE802.3u (100BASE-TX) | |
Transmission speed | 100 Mbps (100BASE-TX) | |
Transmission connector | RJ-45 × 2 | |
Distance between nodes | 100 m 328 ft or less | |
Max. number of station connections |
4,095 stations (65,535 stations when set from master side) | |
Transmission cable | Category 5e or more | |
Ambient temperature | 0 to +55 ℃ +32 to +131 ℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158 ℉ |
|
Ambient humidity | 10 to 90 % RH, Storage: 10 to 90 % RH | |
Material | Enclosure: ABS | |
Weight | 140 g approx. |
Notes:
1) | The current consumption value shown here is the total of the maximum current (D-G line only) supplied to the S-LINK V I/O units and the current consumption of the S-LINK V gateway controller. |
---|---|
2) | This product is not equipped with any short-circuit protective function. For this reason, select a power supply unit having short-circuit protective function (fuse, etc.). |
3) | The VCTF cable is the vinyl cabtyre cable that conforms to the requirements of JIS C 3306 "Polyvinyl chloride insulated flexible cords." |
4) | In case connecting to commercially offered product, be sure to check with this product. Station No., transmission distance, transmission speed depend on the connected product. |
Designation | S-LINK V gateway controller for CC-Link | |||||
---|---|---|---|---|---|---|
Model No. | SL-VGU1-C | |||||
Supply voltage | 24V DC +10-5 % | |||||
Current consumption | 300mA or less (excluding error output load and power supply for driving I/O units) (Note 2) | |||||
Allowable through current | 7A (Note 3) | |||||
S-LINK V system side |
Transmission speed | A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbps | ||||
Refresh time | A mode: 0.29 to 10.32ms, B mode: 1.18 to 41.29ms, C mode: 4.70 to 165.15ms | |||||
I/O points | Buffer memory assignment pattern 1: 128 inputs max., 128 outputs max. (Note 4) Buffer memory assignment pattern 2: 256 inputs max., 256 outputs max. (Note 5) |
|||||
Connected node No. | 256 nodes max. | |||||
Transmission distance | A mode: 50m max., B mode: 200m max., C mode: 800m max. | |||||
Total wiring length | A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or less | |||||
Transmission cable |
Exclusive 4-core flat cable (0.5mm2) or Conductor cross-section area 0.3 to 2.0mm2 4-core VCTF cable (without shield) (Note 6) | |||||
I/O combination | I/O settable in units of 32 Nos. | |||||
Error output | NPN open-collector transistor | |||||
CC-Link side |
Compatible network | CC-Link Ver.1.10 | ||||
Occupied station No. | 1 to 4 stations (varies with S-LINK V I/O control points.) | |||||
Transmission speed | 10Mbps | 5Mbps | 2.5Mbps | 625kbps | 156kbps | |
Total extension | 100m | 160m | 400m | 900m | 1,200m | |
Transmission cable | Specified cable (shielded twisted pair cable) | |||||
Remote unit claccification |
Remote device unit | |||||
Ambient temperature | 0 to +55℃ (No dew condensation), Storage: -20 to +70℃ | |||||
Ambient humidity | 10 to 90% RH, Storage: 10 to 90% RH | |||||
Material | Enclosure: ABS | |||||
Weight | Approx. 200g |
Notes:
1) | Mainly the S-LINK Vsystem side specifications are given above. The CC-Link side conforms to CC-Link specifications. Please confirm the details from CC-Link Partner Association. |
---|---|
2) | The current consumption value shown here is the total of the maximum current (D-G line only) supplied to the S-LINK V I/O units and the current consumption of the S-LINK V gateway controller. |
3) | This product is not equipped with any short-circuit protective function. For this reason, select a power supply unit having short-circuit protective function (fuse, etc.). |
4) | In case of buffer memory assignment pattern 1, 112 channels are assigned to remote I/O (RX / RY) and the balance 16 channels are assigned to remote register (RWrm / RWwm). |
5) | If buffer memory assignment pattern 2 is used, all the points will be assigned to the remote registers (RWrm / RWwm). |
6) | The VCTF cable is the vinyl cabtyre cable that conforms to the requirements of JIS C 3306 "Polyvinyl chloride insulated flexible cords." |
Designation | S-LINK V gateway controller for DeviceNet | |||
---|---|---|---|---|
Model No. | SL-VGU1-D | |||
Supply voltage | 24V DC +10-5 % | |||
Current consumption | 300mA or less (excluding error output load and power supply for driving I/O units) (Note 2) |
|||
Allowable through current | 7A (Note 3) | |||
S-LINK V system side |
Transmission speed | A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbps | ||
Refresh time | A mode: 0.29 to 10.32ms, B mode: 1.18 to 41.29ms C mode: 4.70 to 165.15ms |
|||
I/O points | 512 points max. | |||
Connected node No. | 256 nodes max. | |||
Transmission distance | A mode: 50m max., B mode: 200m max., C mode: 800m max. | |||
Total wiring length | A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or less | |||
Transmission cable |
Exclusive 4-core flat cable(0.5mm2) or Conductor cross-section area 0.3 to 2.0mm2 4-core VCTF cable (without shield) (Note 4) | |||
I/O combination | I/O settable in units of 32 Nos. | |||
Error output | NPN open-collector transistor | |||
DeviceNet side |
Compatible network | DeviceNet Specifications Release 2.0 | ||
Transmission protocol |
Poll, Change of State, Cyclic | |||
Address setting | 0 to 63 (set by address setting switch) | |||
Transmission speed | 500kbps | 250kbps | 125kbps | |
Total extension | 100m | 250m | 500m | |
Transmission cable | Exclusive DeviceNet cable | |||
Ambient temperature | 0 to +55℃ (No dew condensation), Storage: -20 to +70℃ | |||
Ambient humidity | 10 to 90% RH, Storage: 10 to 90% RH | |||
Material | Enclosure: ABS | |||
Weight | Approx. 200g |
Notes:
1) | Mainly the S-LINK Vsystem side specifications are given above. The DeviceNet side conforms to DeviceNet specifications. Please confirm the details from ODVA (Open DeviceNet Vendor Association). |
---|---|
2) | The current consumption value shown here is the total of the maximum current (D-G line only) supplied to the S-LINK V I/O units and the current consumption of the S-LINK V gateway controller. |
3) | This product is not equipped with any short-circuit protective function. For this reason, select a power supply unit having short-circuit protective function (fuse, etc.). |
4) | The VCTF cable is the vinyl cabtyre cable that conforms to the requirements of JIS C 3306 "Polyvinyl chloride insulated flexible cords." |
5) | EDS file is required before using this product. |
|