【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Static Control Devices > Static Control Devices > Bench Top Ionizer Cleaning Box EC-B > Specifications
Type | 200 mm 7.874 in width type | 400 mm 15.748 in width type | |
---|---|---|---|
Model No. | EC-B01-EX | EC-B02-EX | |
Charge removal time (±1,000 V → ±100 V) |
0.5 sec. approx. or less (Note 2) | ||
Ion balance | ±10 V or less | ||
Applicable fluid | Air (dried clean air) | ||
Supplied air flow | Max. 300 ℓ/min. (ANR) or less | Max. 500 ℓ/min. (ANR) or less | |
Air pressure range | 0.05 to 0.50 MPa | ||
Power supply voltage | Accessory AC adapter (Note 3) INPUT: 100-240 V AC ±10 % 50/60 Hz (OUTPUT: 24 V DC) |
||
Power consumption | 80 VA or less | 90 VA or less | |
Dust removal operation output | Photocoupler output / Universal ・Max sink current: 100 mA ・Residual voltage: 2.5 V or less (at sink current of 100 mA or less) |
||
Output operation | During dust removal operation: ON, during standby: OFF | ||
External input | 0 V short-circuit: Input received | ||
Timer mode | 2 sec. / 5 sec. / 10 sec. / synchronized with sensor or with external input selectable by switch | ||
Pulse air mode | Pulse 1 (long) / Pulse 2 (short) / OFF (continuous) selectable by switch | ||
Ambient temperature | 0 to +40 ℃ +32 to +104 ℉ | ||
Ambient humidity | 35 % to 65 % RH (No dew condensation) | ||
Enclosure earthing method | C (capacitor) earth | ||
Net weight | Main body: 6.5 kg approx. | Main body: 13 kg approx. | |
Accessories | AC adapter: 1pc., Filter: 1pc., Protective mesh: 1pc. |
Notes:
1) Where measurement conditions have not been specified precisely,
the conditions used were an ambient temperature of +20℃ +68℉.
2) Typical value at 100 mm 3.937 in from the front of air outlet at an applied air pressure of 0.50 MPa.
3) Please prepare an AC cable separately as it is needed. The following cables are available as optionals:
CN-ACCN-C2: AC cable (conforming to CCC),
CN-ACKR-C2: AC cable (conforming to KTL)
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)