Response time of FX-500 series.
Mode | HYPR | U-LG | LONG | STD | FAST | H-SP |
---|---|---|---|---|---|---|
Response time | 24ms or less | 4ms or less | 2ms or less | 250μs or less | 60μs or less | 25μs or less |
■Thru-beam type(one pair set)
Type | Model No. |
Sensing range(mm) (Note1) | ||||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
Square head | M3 | FT-R31 | 1,000 | 580 | 440 | 270 | 160 | 55 |
M4 | FT-R43 | 3,000 | 1,600 | 1,100 | 720 | 430 | 130 | |
FT-R41W | 3,200 | 1,800 | 1,400 | 800 | 460 | 150 | ||
FT-R42W | 3,600 (Note2) | 3,600 (Note2) | 3,500 | 2,200 | 1,300 | 460 | ||
FT-R44Y | 3,000 | 1,600 | 1,100 | 720 | 430 | 130 | ||
M6 | FT-R60Y | 3,600 (Note2) | 3,600 (Note2) | 3,600 (Note2) | 2,100 | 1,260 | 400 |
Note1: | Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Note1: | Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note2: | The sensing range is specified for white non-glossy paper. |
For details of Square Head Fiber, refer to product information page.
>>Go to "Square Head Fiber"
■Thru-beam type (one pair set)
Note: | The fiber cable length practically limits the sensing range. |
---|
■Reflective type
Note: | The sensing range is specified for white non-glossy paper. |
---|
For details of Super Quality Fiber, refer to product information page.
>>Go to "Super Quality Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) (Note 1) | |||||||
---|---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||||
Threaded | M3 | FT-31 | 1,350 | 770 | 550 | 315 | 210 | 70 | |
FT-31W | 990 | 590 | 440 | 260 | 150 | 53 | |||
FT-32 | 3,600 (Note 2) |
3,600 (Note 2) |
3,600 (Note 2) |
3,000 | 1,600 | 580 | |||
M4 | FT-43 | 3,600 (Note 2) |
2,800 | 2,100 | 1,400 | 770 | 240 | ||
FT-42 | 3,600 (Note 2) |
2,050 | 1,600 | 1,130 | 530 | 190 | |||
FT-42W | 3,300 | 1,900 | 1,400 | 800 | 490 | 160 | |||
FT-45X | 1,600 (Note 2) |
1,600 (Note 2) |
1,600 (Note 2) |
1,200 | 630 | 200 | |||
Elbow | FT-R40 | 3,600 (Note 2) |
1,750 | 1,500 | 930 | 500 | 160 | ||
M14 | Long range | FT-140 | 19,600 (Note 2) |
19,600 (Note 2) |
19,600 (Note 2) |
19,600 (Note 2) |
16,000 | 6,300 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Model No. | Sensing range (mm) (Note 1, 2) | |||||||
---|---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||||
Threaded | M3 | FD-31 | 515 | 290 | 220 | 125 | 80 | 25 | |
FD-31W | 330 | 180 | 140 | 80 | 45 | 12 | |||
FD-32G | 650 | 380 | 270 | 200 | 95 | 27 | |||
FD-32GX | 630 | 410 | 360 | 200 | 100 | 30 | |||
FD-34G | 330 | 185 | 135 | 90 | 49 | 15 | |||
Ultra-small diameter | FD-EG30 | 170 | 130 | 110 | 48 | 30 | 9 | ||
FD-EG31 | 85 | 45 | 35 | 20 | 12 | 3.5 | |||
M4 | FD-41 | 515 | 290 | 220 | 125 | 80 | 25 | ||
FD-41W | 900 | 630 | 430 | 270 | 150 | 45 | |||
FD-42G | 650 | 380 | 270 | 200 | 95 | 27 | |||
FD-42GW | 670 | 340 | 280 | 150 | 90 | 25 | |||
M6 | FD-62 | 1,500 | 1,000 | 940 | 520 | 340 | 110 | ||
FD-61 | 1,400 | 840 | 670 | 450 | 200 | 70 | |||
FD-61W | 900 | 630 | 430 | 270 | 150 | 45 | |||
FD-61G | 1,100 | 800 | 650 | 420 | 200 | 60 | |||
FD-64X | 670 | 500 | 410 | 280 | 160 | 50 | |||
Elbow | FD-R60 | 1,100 | 600 | 550 | 290 | 190 | 65 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Threaded Type Fiber, refer to product information page.
>>Go to "Threaded Type Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) (Note 1) | |||||||
---|---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||||
Cylindrical | φ1 | FT-S11 | 350 | 210 | 160 | 90 | 60 | 19 | |
φ1.5 | FT-S21 | 1,350 | 770 | 550 | 315 | 210 | 70 | ||
FT-S21W | 990 | 590 | 440 | 260 | 150 | 53 | |||
FT-S22 | 1,500 | 920 | 730 | 450 | 250 | 90 | |||
φ2.5 | FT-S32 | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,100 | 1,800 | 600 | ||
φ3 | FT-S31W | 3,300 | 1,900 | 1,400 | 800 | 490 | 160 | ||
Ultra-small diameter | φ3 | FT-E13 | 52 | 30 | 24 | 15 | 8 | 2 | |
FT-E23 | 270 | 160 | 125 | 75 | 42 | 13 | |||
Side-view | φ4 | FT-V40 | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,500 | 2,400 | 850 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Model No. | Sensing range (mm) (Note 1, 2) | |||||||
---|---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||||
Cylindrical | φ1.5 | FD-S21 | 190 | 130 | 110 | 80 | 37 | 11 | |
φ3 | FD-S32 | 1200 | 790 | 660 | 420 | 220 | 75 | ||
FD-S32W | 900 | 630 | 430 | 270 | 150 | 45 | |||
FD-S31 | 515 | 290 | 220 | 125 | 80 | 25 | |||
FD-S33GW | 670 | 340 | 280 | 150 | 90 | 25 | |||
FD-S34G | 330 | 185 | 135 | 90 | 49 | 15 | |||
Ultra-small diameter | φ1.5 | FD-E13 | 50 | 29 | 25 | 12 | 7 | 2 | |
φ3 | FD-E23 | 170 | 120 | 80 | 55 | 30 | 9 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Cylindrical Type Fiber, refer to product information page.
>>Go to "Cylindrical Type Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) (Note 1, 2) | |||||||
---|---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||||
Threaded | M3 | FT-31S | 1,220 | 740 | 550 | 315 | 195 | 63 | |
M4 | FT-42S | 3,600 (Note 2) | 2,050 | 1,600 | 1,130 | 530 | 190 | ||
Cylindrical | Ultra-small diameter | φ3 | FT-E13 | 52 | 30 | 24 | 15 | 8 | 2 |
FT-E23 | 270 | 160 | 125 | 75 | 42 | 13 | |||
Side-view | φ2 | FT-V23 | 1,800 | 1,000 | 880 | 450 | 280 | 90 | |
FT-V25 | 900 | 550 | 480 | 240 | 140 | 45 | |||
FT-V24W | 380 | 230 | 200 | 110 | 60 | 20 | |||
φ2.5 | FT-V30 | 2,200 | 1,200 | 1,000 | 680 | 340 | 100 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Model No. | Sensing range (mm) (Note 1, 2) | |||||||
---|---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||||
Threaded | Ultra-small diameter | M3 | FD-EG30S | 170 | 110 | 80 | 50 | 30 | 9 |
M4 | FD-41S | 515 | 290 | 220 | 125 | 80 | 25 | ||
FD-41SW | 330 | 180 | 140 | 80 | 45 | 12 | |||
M6 | FD-61S | 1,200 | 790 | 660 | 420 | 220 | 75 | ||
Cylindrical | Ultra-small diameter | φ1.5 | FD-E13 | 50 | 29 | 25 | 12 | 7 | 2 |
φ3 | FD-E23 | 170 | 120 | 80 | 55 | 30 | 9 | ||
Side-view | φ3 | FD-V30 | 240 | 130 | 120 | 65 | 35 | 14 | |
FD-V30W | 80 | 40 | 30 | 20 | 10 | 2 | |||
φ5 | FD-V50 | 370 | 220 | 210 | 120 | 75 | 25 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Sleeve Fiber, refer to product information page.
>>Go to "Sleeve Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) (Note 1) | ||||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
Flat | FT-Z30H | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,500 | 2,600 | 810 | |
FT-Z30HW | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,500 | 2,600 | 810 | ||
FT-Z30E | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,500 | 2,400 | 740 | ||
FT-Z30EW | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,400 | 2,000 | 630 | ||
FT-Z30 | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 2,100 | 1,200 | 410 | ||
FT-Z30W | 3,600 (Note 2) | 3,300 | 3,200 | 1,500 | 1,000 | 280 | ||
With boss | FT-Z20W | 1,600 (Note 2) | 1,500 | 1,100 | 620 | 420 | 130 | |
FT-Z20HBW | 1,100 | 670 | 570 | 260 | 180 | 55 | ||
FT-Z40W | 3,600 (Note 2) | 3,300 | 2,300 | 1,500 | 900 | 290 | ||
FT-Z40HBW | 3,300 | 1,900 | 1,400 | 800 | 490 | 160 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Flat Type Fiber, refer to product information page.
>>Go to "Flat Type Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) (Note 1) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||
Narrow beam | FT-KS40 | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 1,200 |
FT-KV40 | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 1,200 | |
FT-KV40W | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,100 | 940 | |
FT-KV26 | 2,500 | 1,600 | 1,200 | 710 | 440 | 160 | |
FT-KV26H1 | 2,200 | 1,430 | 1,070 | 630 | 390 | 135 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Retroreflective type
Type | Model No. | Sensing range (mm) (Note 1, 2) | ||||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
With polarizing filters | FR-Z50HW | 100 to 1,900 | 100 to 1,400 | 100 to 1,200 | 100-990 | 100 to 780 | 100 to 490 | |
Wafer mapping | FR-KZ22E | 15 to 570 | 15 to 460 | 15 to 410 | 15 to 310 | 15 to 220 | 15 to 100 | |
Narrow beam | Top sensing | FR-KZ50H | 20 to 1,000 | 20 to 800 | 20 to 400 | 20 to 300 | 20 to 200 | 20 to 200 |
Side sensing | FR-KZ50E | 20 to 1,000 | 20 to 800 | 20 to 400 | 20 to 300 | 20 to 200 | 20 to 200 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. |
■Reflective type
Type | Model No. | Sensing range (mm) (Note) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||
Long range | FD-Z50HW | 10 to 2,500 | 10 to 1,100 | 10 to 1,000 | 10 to 650 | 10 to 410 | 15 to 130 |
Note: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|
For details of Narrow Beam Fiber, refer to product information page.
>>Go to "Narrow Beam Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) (Note 1) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||
Wide beam | FT-A32 | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 2,100 |
FT-A32W | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,000 | |
FT-A11 | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 1,100 | |
FT-A11W | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 1,300 | |
Array | FT-AL05 | 2,300 | 1,550 | 1,500 | 860 | 500 | 170 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range to 3,600 mm long. |
■Reflective type
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Wide Beam Fiber, refer to product information page.
>>Go to "Wide Beam Fiber"
■Reflective type
Type | Model No. | Sensing range (mm) (Note 1, 2) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||
Glass substrate detection | FD-L32H | 0 to 110 | 0 to 87 | 0 to 74 | 0 to 56 | 1 to 38 | - |
FD-L30A | 0 to 43 | 0 to 43 | 0 to 43 | 0 to 43 | 0 to 42 | 0 to 29 | |
FD-L31A | 3 to 35 | 4 to 33 | 4 to 33 | 4 to 33 | 4 to 32 | 5 to 25 | |
FD-L22A | 0 to 31 | 0 to 28 | 0 to 27 | 0 to 24 | 0 to 24 | 0 to 18 | |
FD-L23 | 0 to 30 | 0 to 30 | 0 to 30 | 0 to 29 | 0 to 28 | 1.5 to 24 | |
FD-L11 | 0 to 11.5 | 0 to 10.5 | 0 to 10 | 0 to 9.5 | 0 to 9 | 0 to 8 | |
FD-L10 | 0 to 6 | 0 to 5.5 | 0 to 5.5 | 0 to 5 | 0 to 4.5 | 0 to 4 | |
FD-L21 | 1 to 19 | 1 to 18 | 1 to 18 | 1.5 to 16 | 2 to 15 | 3 to 12 | |
FD-L21W | 1.5 to 15 | 2 to 15 | 2 to 15 | 3 to 14 | 4 to 14 | 6.5 to 10 | |
General purpose | FD-L20H | 0 to 45 | 0 to 35 | 0 to 32 | 0 to 23 | 2 to 15 | 5 to 9 |
Ultla-small | FD-L12W | 0 to 14 | 0 to 12.5 | 0 to 12 | 0 to 8 | 0.5 to 7 | 0.5 to 4 |
Note 1: | The sensing range is specified for transparent glass 100 x 100 x t0.7 mm (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm). |
---|---|
Note 2: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
For details of Convergent Reflective Type Fiber, refer to product information page.
>>Go to "Convergent Reflective Type Fiber"
■Retroreflective type
Type | Model No. | Sensing range (mm) (Note 1, 2) | ||||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
With polarizing filters | FR-Z50HW | 100 to 1,900 | 100 to 1,400 | 100 to 1,200 | 100 to 990 | 100 to 780 | 100 to 490 | |
Wafer mapping | FR-KZ22E | 15 to 570 | 15 to 460 | 15 to 410 | 15 to 310 | 15 to 220 | 15 to 100 | |
Narrow beam | Top sensing | FR-KZ50H | 20 to 1,000 | 20 to 800 | 20 to 400 | 20 to 300 | 20 to 200 | 20 to 200 |
Side sensing | FR-KZ50E | 20 to 1,000 | 20 to 800 | 20 to 400 | 20 to 300 | 20 to 200 | 20 to 200 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. |
For details of Retroreflective Type Fiber, refer to product information page.
>>Go to "Retroreflective Type Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) (Note 1) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||
Chemical-resistant | FT-Z802Y | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,100 | 1,900 | 470 |
FT-HL80Y | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 2,300 | 740 | |
FT-L80Y | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 3,600 (Note 2) | 2,800 | 920 | |
FT-V80Y | 3,600 (Note 2) | 2,800 | 2,200 | 1,300 | 800 | 240 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Model No. | Sensing range (mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP |
||
Chemical-resistant | FD-S60Y | 600 | 590 | 420 | 320 | 200 | 75 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Chemical-resistant Fiber, refer to product information page.
>>Go to "Chemical-resistant Fiber"
■Thru-beam type (one pair set)
Type | Heat-resistant temp. |
Model No. | Sensing range (mm) (Note 1) | |||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
Heat-resistant | 350℃ | FT-H35-M2 | 1,200 | 880 | 670 | 430 | 250 | 80 |
FT-H35-M2S6 | 1,200 | 880 | 670 | 430 | 250 | 80 | ||
200℃ | FT-H20W-M1 | 1,600 (Note 2) | 1,000 | 840 | 470 | 300 | 90 | |
FT-H20-M1 | 1,600 (Note 2) | 1,300 | 960 | 540 | 330 | 110 | ||
130℃ | FT-H13-FM2 | 3,300 | 1,900 | 1,300 | 700 | 410 | 140 | |
Heat-resistant (joint) | 200℃ | FT-H20-J20-S | 1,600 | 1,000 | 790 | 470 | 300 | 90 |
FT-H20-J30-S | 1,600 | 1,000 | 790 | 470 | 300 | 90 | ||
FT-H20-J50-S | 1,600 | 1,000 | 790 | 470 | 300 | 90 | ||
FT-H20-VJ50-S | 2,100 | 1,300 | 980 | 600 | 390 | 120 | ||
FT-H20-VJ80-S | 2,100 | 1,300 | 980 | 600 | 390 | 120 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Heat-resistant temp. |
Model No. | Sensing range (mm) (Note 1, 2) | ||||||
---|---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | ||||
Heat-resistant | Threaded | 350℃ | FD-H35-M2 | 720 | 540 | 460 | 260 | 150 | 45 |
FD-H35-M2S6 | 720 | 540 | 460 | 260 | 150 | 45 | |||
FD-H35-20S | 840 | 550 | 440 | 260 | 140 | 45 | |||
200℃ | FD-H20-M1 | 840 | 550 | 500 | 330 | 200 | 55 | ||
FD-H20-21 | 770 | 500 | 380 | 230 | 130 | 45 | |||
130℃ | FD-H13-FM2 | 880 | 640 | 600 | 350 | 200 | 65 | ||
Glass substrate detection convergent reflective | 300℃ | FD-H30-L32 | 0 to 40 | 0 to 30 | 0 to 25 | 0 to 17 | 0 to 12 | 1.5 to 6 | |
250℃ | FD-H25-L43 | 1 to 31 | 1 to 30 | 1 to 28 | 1.5 to 26 | 1.5 to 24 | 2 to 18 | ||
FD-H25-L45 | 4 to 43.5 | 4 to 43 | 4.5 to 43 | 5 to 42 | 5 to 40 | 6.5 to 34 | |||
180℃ | FD-H18-L31 | 0 to 60 | 0 to 32 | 0 to 24 | 0 to 16 | 0 to 13 | 2 to 6.5 |
Note 1: | The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm glass substrate for FD-H30-L32 and FD-H18-L31, transparent glass 100 x 100 x t0.7 mm for FD-H25-L43 and FD-H25-L45). |
---|---|
Note 2: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
For details of Heat-resistant Fiber, refer to product information page.
>>Go to "Heat-resistant Fiber"
■Thru-beam type
Type | Model No. | Sensing range (mm)(Note 1) | ||||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
Vacuum- resistant |
Thru-beam | FT-40V | 1,000 | 590 | 470 | 270 | 160 | 55 |
(Note 1): | Atmospheric side fiber, FT-J9 (optional) is free-cut type. Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|
■Reflective type
(Note 1): | The sensing range is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in. |
---|---|
(Note 2): | Atmospheric side fiber, FT-J9 (optional) is free-cut type. Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
For details of One-Touch Connection System Vacuum-resistant Fibers, refer to product information page.
>>Go to "One-Touch Connection System Vacuum-resistant Fibers"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) | ||||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
Vacuum-resistant | Thru-beam | FT-H30-M1V-S | 1,000 | 590 | 470 | 270 | 160 | 55 |
■Reflective type
Type | Model No. | Sensing range (mm) (Note) | ||||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
Vacuum-resistant | Reflective | FD-H30-KZ1V-S | 5 to 500 | 10 to 340 | 15 to 270 | 20 to 200 | 20 to 120 | 20 to 45 |
Convergent reflective | FD-H30-L32V-S | 0 to 18 | 0 to 12 | 0 to 10 | 0 to 8 | 0 to 5.5 | 1.5 to 3 |
Note: | The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm. |
---|
For details of Vacuum-resistant Fiber, refer to product information page.
>>Go to "Vacuum-resistant Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range (mm) (Note) | ||||||
---|---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | H-SP | |||
Threaded | M4 | FT-41 | 3,300 | 2,000 | 1,550 | 1,100 | 445 | 150 |
Note: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|
■Reflective type
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Metal-free Fiber, refer to product information page.
>>Go to "Metal-free Fiber"
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)