SF4B-H□C(A-J05)
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) | ||||||
---|---|---|---|---|---|---|---|
Pigtailed type | SF4B- H12CA-J05 |
SF4B- H16CA-J05 |
SF4B- H20CA-J05 |
SF4B- H24CA-J05 |
SF4B- H28CA-J05 |
||
Cable type | SF4B-H12C | SF4B-H16C | SF4B-H20C | SF4B-H24C | SF4B-H28C | ||
Number of beam channels | 12 | 16 | 20 | 24 | 28 | ||
Protective height | 263.4 mm 10.37 in |
343.4 mm 13.52 in |
423.4 mm 16.669 in |
503.4 mm 19.819 in |
583.4 mm 22.969 in |
||
Current consumption | Cable type | Emitter: 65 mA or less Receiver: 75 mA or less |
Emitter: 70 mA or less Receiver: 85 mA or less |
||||
Pigtailed type |
When large multi-purpose indicator turns OFF |
||||||
When large multi-purpose indicator lights up |
Emitter: 75 mA or less Receiver: 85 mA or less |
Emitter: 80 mA or less Receiver: 95 mA or less |
|||||
PFHD (Note) | 1.9×10-9 | 2.1×10-9 | 2.4×10-9 | 2.6×10-9 | 2.8×10-9 | ||
MTTFD (Note) | 100 years or more | ||||||
Net weight (Total of emitter and receiver) |
Pigtailed type | 360 g approx. |
430 g approx. |
520 g approx. |
590 g approx. |
680 g approx. |
|
Cable type | 700 g approx. |
770 g approx. |
860 g approx. |
930 g approx. |
1,000 g approx. |
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) | |||||
---|---|---|---|---|---|---|
Pigtailed type | SF4B-H32CA-J05 | SF4B-H36CA-J05 | SF4B-H40CA-J05 | SF4B-H48CA-J05 | ||
Cable type | SF4B-H32C | SF4B-H36C | SF4B-H40C | SF4B-H48C | ||
Number of beam channels | 32 | 36 | 40 | 48 | ||
Protective height | 663.4 mm 26.118 in |
743.4 mm 29.268 in |
823.4 mm 32.417 in |
983.4 mm 38.717 in |
||
Current consumption | Cable type | Emitter: 75 mA or less Receiver: 95 mA or less |
Emitter: 80 mA or less Receiver: 100 mA or less |
|||
Pigtailed type |
When large multi-purpose indicator turns OFF |
|||||
When large multi-purpose indicator lights up |
Emitter: 85 mA or less Receiver: 105 mA or less |
Emitter: 90 mA or less Receiver: 110 mA or less |
||||
PFHD (Note) | 3.0×10-9 | 3.3×10-9 | 3.5×10-9 | 3.9×10-9 | ||
MTTFD (Note) | 100 years or more | |||||
Net weight (Total of emitter and receiver) |
Pigtailed type | approx. 750 g |
approx. 840 g |
approx. 910 g |
approx. 1,100 g |
|
Cable type | approx. 1,100 g | approx. 1,200 g | approx. 1,300 g | approx. 1,400 g |
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) | |||||
---|---|---|---|---|---|---|
Pigtailed type | SF4B-H56CA-J05 | SF4B-H64CA-J05 | SF4B-H72CA-J05 | SF4B-H80CA-J05 | ||
Cable type | SF4B-H56C | SF4B-H64C | SF4B-H72C | SF4B-H80C | ||
Number of beam channels | 56 | 64 | 72 | 80 | ||
Protective height | 1,143.4 mm 45.016 in |
1,303.4 mm 51.315 in |
1,463.4 mm 57.614 in |
1,623.4 mm 63.913 in |
||
Current consumption | Cable type | Emitter: 85 mA or less Receiver: 120 mA or less |
Emitter: 95 mA or less Receiver: 130 mA or less |
|||
Pigtailed type |
When large multi-purpose indicator turns OFF |
|||||
When large multi-purpose indicator lights up |
Emitter: 95 mA or less Receiver: 130 mA or less |
Emitter: 105 mA or less Receiver: 140 mA or less |
||||
PFHD (Note) | 4.4 × 10-9 | 4.8 × 10-9 | 5.3 × 10-9 | 5.7 × 10-9 | ||
MTTFD (Note) | 100 years or more | |||||
Net weight (Total of emitter and receiver) |
Pigtailed type | approx. 1,300 g | approx. 1,400 g | approx. 1.600 g | approx. 1,700 g | |
Cable type | approx. 1,600 g | approx. 1,700 g | approx. 2,000 g | approx. 2,000 g |
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) | |||
---|---|---|---|---|
Pigtailed type | SF4B-H88CA-J05 | SF4B-H96CA-J05 | ||
Cable type | SF4B-H88C | SF4B-H96C | ||
Number of beam channels | 88 | 96 | ||
Protective height | 1,783.4 mm 70.212 in |
1,943.4 mm 76.512 in |
||
Current consumption | Cable type | Emitter: 100 mA or less Receiver: 140 mA or less |
Emitter: 105 mA or less Receiver: 145 mA or less |
|
Pigtailed type |
When large multi-purpose indicator turns OFF |
|||
When large multi-purpose indicator lights up |
Emitter: 110 mA or less Receiver: 155 mA or less |
Emitter: 115 mA or less Receiver: 155 mA or less |
||
PFHD (Note) | 6.2 × 10-9 | 6.6 × 10-9 | ||
MTTFD (Note) | 100 years or more | |||
Net weight (Total of emitter and receiver) |
Pigtailed type | approx. 1,800 g | approx. 1,900 g | |
Cable type | approx. 2,100 g | approx. 2,200 g |
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)
SF4B-A□C(A-J05)
Type | Min. sensing object ø45 mm ø1.772 in (40 mm1.575 in beam pitch) | |||||
---|---|---|---|---|---|---|
Pigtailed type | SF4B-A8CA-J05 | SF4B-A12CA-J05 | SF4B-A16CA-J05 | SF4B-A20CA-J05 | ||
Cable type | SF4B-A8C | SF4B-A12C | SF4B-A16C | SF4B-A20C | ||
Number of beam channels | 8 | 12 | 16 | 20 | ||
Protective height | 343.4 mm 13.52 in |
503.4 mm 19.819 in |
663.4 mm 26.118 in |
823.4 mm 32.417 in |
||
Current consumption | Cable type | Emitter: 60 mA or less Receiver: 70 mA or less |
Emitter: 65 mA or less Receiver: 75 mA or less |
|||
Pigtailed type |
When large multi-purpose indicator turns OFF |
|||||
When large multi-purpose indicator lights up |
Emitter: 70 mA or less Receiver: 80 mA or less |
Emitter: 75 mA or less Receiver: 85 mA or less |
||||
PFHD (Note) | 1.7× 10-9 | 1.9× 10-9 | 2.2× 10-9 | 2.4× 10-9 | ||
MTTFD (Note) | 100 years or more | |||||
Net weight (Total of emitter and receiver) |
Pigtailed type | approx. 430 g |
approx. 590 g |
approx. 750 g |
approx. 910 g |
|
Cable type | approx. 770 g |
approx. 930 g |
approx. 1,100 g |
approx. 1,300 g |
Type | Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) | ||||||
---|---|---|---|---|---|---|---|
Pigtailed type | SF4B- A24CA-J05 |
SF4B- A28CA-J05 |
SF4B- A32CA-J05 |
SF4B- A36CA-J05 |
SF4B- A40CA-J05 |
||
Cable type | SF4B-A24C | SF4B-A28C | SF4B-A32C | SF4B-A36C | SF4B-A40C | ||
Number of beam channels | 24 | 28 | 32 | 36 | 40 | ||
Protective height | 983.4 mm 38.717 in |
1,143.4 mm 45.016 in |
1,303.4 mm 51.315 in |
1,463.4 mm 57.614 in |
1,623.4 mm 63.913 in |
||
Current consumption | Cable type | Emitter: 70 mA or less, Receiver: 85 mA or less |
Emitter: 75 mA or less Receiver: 95 mA or less |
||||
Pigtailed type |
When large multi-purpose indicator turns OFF |
||||||
When large multi-purpose indicator lights up |
Emitter: 80 mA or less, Receiver: 95 mA or less |
Emitter: 85 mA or less Receiver: 105 mA or less |
|||||
PFHD (Note) | 2.7 × 10-9 | 2.9 × 10-9 | 3.2 × 10-9 | 3.4 × 10-9 | 3.7 × 10-9 | ||
MTTFD (Note) | 100 years or more | ||||||
Net weight (Total of emitter and receiver) |
Pigtailed type | approx. 1,100 g |
approx. 1,300 g |
approx. 1,400 g |
approx. 1,600 g |
approx. 1,700 g |
|
Cable type | approx. 1,400 g |
approx. 1,600 g |
approx. 1,700 g |
approx. 2,000 g |
approx. 2,000 g |
Type | Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) | |||
---|---|---|---|---|
Pigtailed type | SF4B-A44CA-J05 | SF4B-A48CA-J05 | ||
Cable type | SF4B-A44C | SF4B-A48C | ||
Number of beam channels | 44 | 48 | ||
Protective height | 1,783.4 mm 70.212 in |
1,943.4 mm 76.512 in |
||
Current consumption | Cable type | Emitter: 80 mA or less, Receiver: 100 mA or less |
||
Pigtailed type |
When large multi-purpose indicator turns OFF |
|||
When large multi-purpose indicator lights up |
Emitter: 90 mA or less, Receiver: 110 mA or less |
|||
PFHD (Note) | 3.9 × 10-9 | 4.2 × 10-9 | ||
MTTFD (Note) | 100 years or more | |||
Net weight (Total of emitter and receiver) |
Pigtailed type | approx. 1,800 g | approx. 1,900 g | |
Cable type | approx. 2,100 g | approx. 2,200 g |
Note: PFHd: Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure.
Type | Pigtailed type (with muting function) | Cable type | |||
---|---|---|---|---|---|
Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) |
Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch) |
||
Model No. | SF4B-H□CA-J05 | SF4B-A□CA-J05 | SF4B-H□C | SF4B-A□C | |
Applicable standards |
International standard | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) | |||
Japan | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3) | ||||
Europe (Note 2) | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 |
||||
North America (Note 3) | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 |
||||
South Korea (S-Mark) | S1-G-35-2005, S2-W-11-2003 | ||||
Applicable regulations and certifications | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification, TÜV SÜD NRTL certification | ||||
Operating range (Note 4) | 0.3 to 7m 0.984 to 22.966 ft | ||||
Beam pitch | 20 mm 0.787 in | 40 mm 1.575 in | 20 mm 0.787 in | 40 mm 1.575 in | |
Min. sensing object (Note 5) | ø25 mm ø0.984 in opaque object | ø45 mm ø1.772 in opaque object | ø25 mm ø0.984 in opaque object | ø45 mm ø1.772 in opaque object | |
Effective aperture angle | ±2.5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | ||||
Supply voltage | 24 V DC ±10 % Ripple P-P 10 % or less | ||||
Control outputs (OSSD 1, OSSD 2) |
PNP open-collector transistor / NPN open-collector transistor (switching method) <For PNP output> (source current 200 mA, when using 20 m 65.617 ft length cable) (sink current 200 mA, when using 20 m 65.617 ft length cable) |
||||
Operation mode | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note 6, 7) | ||||
Protection circuit | Incorporated | ||||
Response time | OFF response: 14 ms or less, ON response: 80 to 90 ms | ||||
Auxiliary output (Non-safety output) |
PNP open-collector transistor / NPN open-collector transistor (switching method) <For PNP output> (source current 60 mA, when using 20 m 65.617 ft length cable) <For NPN output> (sink current 60 mA, when using 20 m 65.617 ft length cable) |
||||
Operation mode | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC(optional) handy-controller.) | ||||
Protection circuit | Incorporated | ||||
Muting auxiliary output | NPN open-collector transistor |
- | |||
Operation mode | When muting auxiliary output: ON | ||||
Protection circuit | Incorporated | ||||
ELCA function | Incorporated (reducing mutual interference automatically) | ||||
Emission halt function | Incorporated | ||||
Interlock function | Incorporated [Manual reset / Auto reset (Note 8)] | ||||
External device monitoring function | Incorporated | ||||
Override function | Incorporated | - | |||
Muting function | Incorporated | - | |||
Large multi-purpose indicator function | Incorporated | - | |||
Optional functions (Note 9) |
Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing | Fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing | |||
Pollution degree | 3 | ||||
Operating altitude | 2,000 m 6,561.68 ft or less (Note 10) | ||||
Environmental resistance | Degree of protection | IP65 (IEC) | |||
Ambient temperature | -10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉ | ||||
Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH | ||||
Ambient illuminance | Incandescent light: 3,500 ℓx or less at the light-receiving face | ||||
Dielectric strength voltage | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
Insulation resistance | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure | ||||
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance |
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each | ||||
Emitting element | Infrared LED (Peak emission wavelength: 850 nm 0.033 mil) | ||||
Material | Enclosure: Polycarbonate | ||||
Cable | 0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long | 0.15 mm2(power line: 0.2 mm2) 8-core heat-resistant PVC cable, 5 m 16.404 ft long | |||
Cable extension | Extension up to total 50 m 164.042 ft is possible for both emitter and receiver optional mating cables | Extension up to total 50 m 164.042 ft is possible for 0.2 mm2 or more, cable (Note 11) | |||
Accessories | SF4B-TR25 (Test rod):1 pc. | - | SF4B-TR25 (Test rod):1 pc. | - |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
2) | Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
3) | The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7 |
4) | The operating range is the possible setting distance between the emitter and the receiver. |
5) | In case the blanking function is valid, the operation mode is changed. For details, refer to Safety distance. |
6) | During muting, control output will not turn off even if the beams are interrupted. |
7) | When the blanking function is enabled, the operating mode will change. |
8) | The manual reset and automatic reset are possible to be switched depending on the wiring status. |
9) | In case of using optional function, the handy-controller SFB-HC(optional) is required. |
10) | Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
For details, refer to Exclusive Control Unit for Safety Light Curtain SF-C10 Specifications
Model No. | SFB-HC |
---|---|
Supply voltage |
24V DC±10% Ripple P-P10 % or less (common to safety light curtain power supply) |
Current consumption | 65 mA or less |
Communication method | RS-485 two-way communications (Specific procedure) |
Digital display | 4-digit red LED display × 2 (Selected beam channels, setting contents etc. are displayed.) |
Function indicator | Green LED × 9 (set function is displayed.) |
Functions | ・ Fixed blanking (Factory setting: Disabled) ・ Floating blanking (Factory setting: Disabled) ・ Auxiliary output changing (Factory setting: Negative Logic of OSSD) ・ Light emitting amount control (Factory setting: Disabled) ・ Muting setting changing [Factory setting: All beam channels enabled, A = B, Setting of the muting lamp diagnosis function enabled (Ver. 2 or later), Muting sensor output operation setting N.O. / N.C. (Ver. 2.1 or later)] ・ Interlock setting changing (Factory setting: start / restart) ・ External device monitoring setting change (Factory setting: Enabled, 300 ms) ・ Override setting changing 60 sec. (Ver. 2.1 or later) ・ Setting detail monitoring ・ Protecting (Factory setting: Disabled) (Factory password setting: 0000) ・ Initialization ・ Copy |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +70 ℃ -13 to +158 ℉ |
Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Cable | 8-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables) |
Weight | Net weight: 200 g approx. |
Accessories | Adapter cable: 2 cables |
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.