Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C > I/O Circuit and Wiring diagrams
<In case of using I/O circuit for PNP output>
・S1, S2
Switch S1 | |
・ | Test input / Reset input For manual reset Vs to Vs – 3.5 V (sink current 5 mA or less): OFF (Note) Open: ON For automatic reset Vs to Vs – 3.5 V (sink current 5 mA or less): ON (Note) Open: OFF |
---|---|
Switch S2 | |
・ | Interlock setting input, Override input, Muting input 1 / 2, Large multi-purpose indicator input 1 / 2, Vs to Vs – 3.5 V (sink current 5 mA or less): Valid (Note) Open: Invalid |
Note: | Vs is the applying supply voltage. |
---|
<In case of using I/O circuit for NPN output>
・S1, S2
Switch S1 | |
・ | Test input / Reset input For manual reset 0 to +2.5 V (source current 5 mA or less): OFF Open: ON For automatic reset 0 to +2.5 V (source current 5 mA or less): OFF Open: ON |
---|---|
Switch S2 | |
・ | Interlock setting input, Override input, Muting input 1 / 2, Large multi-purpose indicator input 1 / 2, 0 to +2.5 V (source current 5 mA or less): Valid Open: Invalid |
Basic wiring: Min. operation only |
This is the general configuration using one set of the emitter and receiver facing each other. The control outputs (OSSD 1 / OSSD 2) turn OFF if the light is interrupted, while they automatically turn ON if receive the light.
The auxiliary output is used to invalid the external device monitoring function. The auxiliary output cannot be connected to external devices.
|
Interlock function | Disabled (Automatic reset) |
---|---|
External device monitoring function | Disabled |
Auxiliary output | Not used |
Output polarity setting wire | PNP |
Safety input | Invalid |
|
Interlock function | Disabled (Automatic reset) |
---|---|
External device monitoring function | Disabled |
Auxiliary output | Not used |
Output polarity setting wire | NPN |
Safety input | Invalid |