Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C

Option

Mounting bracket

Designation Model No. Description
NA2-N
compatible
mounting
bracket
MS-SFC-2 Used when changing over area sensor NA2-N series to the SF4C series. The mounting holes of NA2-N series can continue to be used. Center mounting by a M6 hexagon-socket-head bolt is also possible.
(4 pcs. per set for emitter and receiver) (Note)
Versatile
bracket
MS-SFC-3 Two ways of mounting are possible.
(1) Rear mounting which enables beam adjustment
(2) Dead zoneless center mounting on aluminum frame
(4 pcs. per set for emitter and receiver) (Note)
Intermediate
supporting
bracket
for versatile
bracket
MS-SFC-4 Used to support the safety light curtain in the middle. Be sure to purchase it when using the versatile bracket MS-SFC-3(optional) on SF4C-F55(-J05),SF4C-F63(-J05), SF4C-H28(-J05) or SF4C-H32(-J05).
(2 pcs. per set for emitter and receiver) (Note)
Note : The body of the safety light curtain is made of resin, so please take into account the expansion and contraction of the longitudinal dimension.
When machining mounting holes, please check the actual product.

NA2-N compatible mounting bracket

MS-SFC-2

Versatile bracket

MS-SFC-3

<Rear mounting>

MS-SFC-3

<Dead zoneless mounting>

MS-SFC-3

Intermediate supporting bracket for versatile bracket

MS-SFC-4

Control unit

Designation Appearance Model No. Description
Slim type
control unit
SF-C13 Use a discrete wire cable to connect to the safety light curtain.
Relay output.
Compatible with up to Control Category 4.

Recommended safety relay

SF relay, slim type
SF seriesopen link in new window

Recommended safety relay
Note:Please contact our sales officeopen link in new window for details on the recommended products.
Type With LED indicator
Model No. SFS3-L-DC24V SFS4-L-DC24V
Part No. AG1S132 AG1S142
Contact arrangement 3a1b 4a2b
Rated nominal switching capacity 6A/250V AC、6A/30V DC
Min. switching capacity 1mA/5V DC
Coil rating 15mA/24V DC 20.8mA/24V DC
Rated power consumption 360mW 500mW
Operation time 20ms or less
Release time 20ms or less
Ambient temperature -40 to +85 ℃ -40 to + 185 ℉
(Humidity: 5 to 85 % RH)
Applicable certifications UL/c-UL, TÜV, Korea S-mark

Y-shaped connector

Type Appearance Model No. Description
Wire-saving
Y-shaped
connector
SFC-WY1 Wire-saving connector for SF4C-F□-J05 and SF4C-H□-J05. Cables of emitter and receiver are consolidated into one cable for wire-saving. Wiring has +24 V, 0 V, OSSD 1, OSSD 2, output polarity setting wire (shield), large multi-purpose indicator input 1, and large multi-purpose indicator input 2 only. Net weight: 40 g approx. Power wire and synchronization wire are connected inside the connector. Interlock is disabled (automatic reset).
Cable with
connector
on one side
WY1-CCN3 Cable length: 3 m 9.843 ft
Net weight: 200 g approx.
(1 cable)
Mating cable for Y-shaped connector Cable color: Gray (with black line) Connector color: Black The min. bending radius: R6 mm R0.236 in Connector outer diameter: ø14 mm ø0.551 in max.
WY1-CCN10 Cable length: 10 m 32.808 ft
Net weight: 620 g approx.
(1 cable)

By using the Y-shaped connector, the least required wires such as power or safety output are consolidated into one cable. Man-hours taken for wiring is eliminated to the minimum. Construction times as well as wiring mistakes are greatly reduced.

Wiring diagram of control unit SF-C13

<For PNP output (minus ground)>
• Connect the safety light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively.

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) Unused wires must be insulated.

<For NPN output (plus ground)>
• Connect the safety light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side.

Notes:
1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button.
3) Unused wires must be insulated.

Handy-controller

Designation Appearance Model No.
Handy controller SFC-HC
Cable set for
cable type
connection
SFC-WNC1

Metal protection case

Applicable
beam channels
Metal protection case
(2 pcs. per set for emitter and receiver)
SF4C-H□ SF4C-F□ Model No.
8 15 MS-SFCH-8
12 23 MS-SFCH-12
16 31 MS-SFCH-16
20 39 MS-SFCH-20
24 47 MS-SFCH-24
28 55 MS-SFCH-28
32 63 MS-SFCH-32

MC-SFCH-□

MC-SFCH-□

MS-SFCH-8

MS-SFCH-8

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)