Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C > Specifications
Type | Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch) |
|||
---|---|---|---|---|
Model No. | Pigtailed type | SF4C-F15-J05 | SF4C-F23-J05 | SF4C-F31-J05 |
Cable type | SF4C-F15 | SF4C-F23 | SF4C-F31 | |
No. of beam channels | 15 | 23 | 31 | |
Protective height | 160 mm 6.299 in |
240 mm 9.449 in |
320 mm 12.598 in |
|
Current consumption |
Large multipurpose indicator lights off | Emitter: 70 mA or less Receiver: 80 mA or less |
Emitter: 75 mA or less Receiver: 85 mA or less |
|
Large multipurpose indicator lights up |
Emitter: 105 mA or less Receiver: 110 mA or less |
Emitter: 110 mA or less Receiver: 115 mA or less |
||
PFHD | 2.29 x 10-9 | 2.73 x 10-9 | 3.18 x 10-9 | |
MTTFD | 100 years or more | |||
Net weight (Total of emitter and receiver) |
Pigtailed type |
210 g approx. | 270 g approx. | 340 g approx. |
Cable type | 600 g approx. | 670 g approx. | 730 g approx. |
Type | Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | Pigtailed type | SF4C-F39 -J05 |
SF4C-F47 -J05 |
SF4C-F55 -J05 |
SF4C-F63 -J05 |
Cable type | SF4C-F39 | SF4C-F47 | SF4C-F55 | SF4C-F63 | |
No. of beam channels | 39 | 47 | 55 | 63 | |
Protective height | 400 mm 15.748 in |
480 mm 18.898 in |
560 mm 22.047 in |
640 mm 25.197 in |
|
Current consumption |
Large multipurpose indicator lights off |
Emitter: 80 mA or less Receiver: 90 mA or less |
Emitter: 85 mA or less Receiver: 95 mA or less |
||
Large multipurpose indicator lights up |
Emitter: 115 mA or less Receiver: 120 mA or less |
Emitter: 120 mA or less Receiver: 125 mA or less |
|||
PFHD | 3.62 x 10-9 | 4.06 x 10-9 | 4.50 x 10-9 | 4.95 x 10-9 | |
MTTFD | 100 years or more | ||||
Net weight (Total of emitter and receiver) |
Pigtailed type |
400 g approx. | 470 g approx. | 540 g approx. | 600 g approx. |
Cable type | 800 g approx. | 860 g approx. | 930 g approx. | 1,000 g approx. |
Type | Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) |
|||
---|---|---|---|---|
Model No. | Pigtailed type | SF4C-H8-J05 | SF4C-H12-J05 | SF4C-H16-J05 |
Cable type | SF4C-H8 | SF4C-H12 | SF4C-H16 | |
No. of beam channels | 8 | 12 | 16 | |
Protective height | 160 mm 6.299 in |
240 mm 9.449 in |
320 mm 12.598 in |
|
Current consumption |
Large multipurpose indicator lights off |
Emitter: 70 mA or less Receiver: 85 mA or less |
Emitter: 70 mA or less Receiver: 90 mA or less |
|
Large multipurpose indicator lights up |
Emitter: 120 mA or less Receiver: 135 mA or less |
Emitter: 120 mA or less Receiver: 140 mA or less |
||
PFHD | 1.66 x 10-9 | 1.90 x 10-9 | 2.10 x 10-9 | |
MTTFD | 100 years or more | |||
Net weight (Total of emitter and receiver) |
Pigtailed type |
240 g approx. | 300 g approx. | 360 g approx. |
Cable type | 630 g approx. | 700 g approx. | 760 g approx. |
Type | Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) |
||||
---|---|---|---|---|---|
Model No. | Pigtailed type | SF4C-H20 -J05 |
SF4C-H24 -J05 |
SF4C-H28 -J05 |
SF4C-H32 -J05 |
Cable type | SF4C-H20 | SF4C-H24 | SF4C-H28 | SF4C-H32 | |
No. of beam channels | 20 | 24 | 28 | 32 | |
Protective height | 400 mm 15.748 in |
480 mm 18.898 in |
560 mm 22.047 in |
640 mm 25.197 in |
|
Current consumption |
Large multipurpose indicator lights off |
Emitter: 75 mA or less Receiver: 95 mA or less |
Emitter: 80 mA or less Receiver: 100 mA or less |
||
Large multipurpose indicator lights up |
Emitter: 120 mA or less Receiver: 145 mA or less |
Emitter: 120 mA or less Receiver: 150 mA or less |
|||
PFHD | 2.33 x 10-9 | 2.54 x 10-9 | 2.77 x 10-9 | 2.98 x 10-9 | |
MTTFD | 100 years or more | ||||
Net weight (Total of emitter and receiver) |
Pigtailed type |
420 g approx. | 490 g approx. | 550 g approx. | 610 g approx. |
Cable type | 820 g approx. | 880 g approx. | 950 g approx. | 1,000 g approx. |
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)
Type | Pigtailed type | Cable type | |||
---|---|---|---|---|---|
Model No. | SF4C-F□-J05 | SF4C-H□-J05 | SF4C-F□ | SF4C-H□ | |
Applicable standards |
International standard |
IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3) |
|||
Japan | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508(SIL 3) |
||||
Europe (Note 2) |
EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 |
||||
North America (Note 3) |
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 |
||||
Applicable regulations and certifications | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification | ||||
Operating range (Note 4) |
0.1 to 3 m 0.328 to 9.843 ft | ||||
Beam pitch | 10 mm 0.394 in | 20 mm 0.787 in | 10 mm 0.394 in | 20 mm 0.787 in | |
Min. sensing object (Note 5) |
ø14 mm ø0.551 in opaque object | ø25 mm ø0.984 in opaque object | ø14 mm ø0.551 in opaque object | ø25 mm ø0.984 in opaque object | |
Effective aperture angle |
±2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] |
||||
Supply voltage | 24 V DC +10-15 % Ripple P-P 10 % or less | ||||
Control outputs (OSSD 1, OSSD 2) |
PNP open-collector transistor / NPN open-collector transistor (switching method) <When selecting PNP output> ・Max. source current: 200 mA ・Applied voltage: same as supply voltage (between the control output and +V) ・Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) ・Leakage current: 200 μA or less (including power supply OFF condition) ・Max. load capacity: 1 μF (No load to Max. source current) ・Load wiring resistance: 3 Ω or less <When selecting NPN output> ・Max. sink current: 200 mA ・Applied voltage: same as supply voltage (between the control output and 0 V) ・Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) ・Leakage current: 200 μA or less (including power supply OFF condition) ・Max. load capacity: 1 μF (No load to Max. sink current) ・Load wiring resistance: 3 Ω or less |
||||
Operation mode |
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note 6,7) |
||||
Protection circuit |
Incorporated | ||||
Response time | OFF response: 9 ms or less, ON response: 90 ms or less | OFF response: 7 ms or less, ON response: 90 ms or less | OFF response: 9 ms or less, ON response: 90 ms or less | OFF response: 7 ms or less, ON response: 90 ms or less | |
Auxiliary output (Non-safety output) |
PNP open-collector transistor / NPN open-collector transistor (switching method) <When selecting PNP output> ・Max. source current: 100 mA ・Applied voltage: same as supply voltage (between the auxiliary source and +V) ・Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable) <When selecting NPN output> ・Max. sink current: 100 mA ・Applied voltage: same as supply voltage (between the auxiliary sink and 0 V) ・Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable) |
||||
Operation mode |
OFF when control outputs are ON, ON when control outputs are OFF [Factory setting, operating mode can be changed using the handy-controller SFC-HC(optional).] | ||||
Protection circuit |
Incorporated | ||||
ELCA function | Incorporated (reducing mutual interference automatically) | ||||
Test / reset input function | Incorporated | ||||
Interlock function | Incorporated [Manual reset / Automatic reset (Note 8)] | ||||
External device monitoring function |
Incorporated | ||||
Safety input function | Incorporated (safety contact) | ||||
Muting function | Incorporated | ||||
Override function | Incorporated | ||||
Optional functions (Note 9) |
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting | ||||
Pollution degree | 3 | ||||
Operating altitude | 2,000 m 6,561 68 ft or less (Note 10) | ||||
Degree of protection | IP67 / IP65 (IEC) | ||||
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉ |
||||
Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH | ||||
Ambient illuminance | Incandescent light: 5,000 lx or less at the light-receiving face | ||||
Dielectric strength voltage |
1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | ||||
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | ||||
Emitting element | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil) | ||||
Material | Enclosure: Polycarbonate alloy, Sensing surface: Polycarbonate alloy, MS-SFC-1 (Standard mounting bracket): SUS | ||||
Cable | 0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long | 0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long | |||
Cable extension | Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver optional mating cables | Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable (Note 11) (Note 12) |
|||
Accessories | MS-SFC-1 (Standard mounting bracket): 1 set,SF4C-TR14 (Test rod): 1 No. | MS-SFC-1 (Standard mounting bracket): 1 set,SF4C-TR25 (Test rod): 1 No. | MS-SFC-1 (Standard mounting bracket): 1 set,SF4C-TR14 (Test rod): 1 No. | MS-SFC-1 (Standard mounting bracket): 1 set,SF4C-TR25 (Test rod): 1 No. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
3) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark.
4) The operating range is the possible setting distance between the emitter and the receiver.
5) When the floating blanking function is used, the size of the min. sensing object is changed.
6) The outputs are not "OFF" when muting function is active even if the beam channel is interruped.
7) In case the blanking function is valid, the operation mode is changed.
8) The manual reset and automatic reset are possible to be switched depending on the wiring status.
9) In case of using optional function, the handy-controller SFC-HC(optional) is required.
10) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
11) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
12) When the synchronization + wire (orange) and synchronization - wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or more shielded twisted pair cable.
Model No. | SFC-HC |
---|---|
Supply voltage | 24 V DC +10-15 % Ripple P-P 10 % or less (common to safety light curtain power supply) |
Current consumption | 65 mA or less |
Communication method | RS-485 two-way communications (Specific procedure) |
Digital display | 4-digit red LED display x 2 (Selected beam channels, setting contents etc. are displayed.) |
Function indicators | Green LED x 9 (Set function is displayed.) |
Functions | Fixed blanking / Floating blanking / Auxiliary output change / Satety input setting change / Large multi-purpose indicator setting change / Muting setting change / Interlock setting change / External device monitoring setting change / Override setting changing function 60 sec. / Protecting |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉ |
Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Cable | 12-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables) |
Weight | Net weight: 200 g approx. |
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)