Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Static Control Devices > Static Control Devices > Pulse AC Method Area Ionizer ER-X > Order guide
|
Head connection cable is not supplied with the head. Please order it separately. |
Type | Appearance | Charge removal time (±1,000 V→±100 V) |
Ion balance | Effective charge removal width |
Model No. | |
---|---|---|---|---|---|---|
Spot type | 0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2) |
±30 V or less (Note 2, 3) |
50 mm 1.969 in approx. |
ER-X001 (Note 4) |
||
Bar type |
1 sec. or less (Note 2) |
80 mm 3.150 in approx. |
ER-X008 (Note 4) |
|||
High and low temperature resistant |
ER-X008HC (Note 5) |
|||||
160 mm 6.299 in approx. |
ER-X016 | |||||
High and low temperature resistant |
ER-X016HC (Note 5) |
|||||
320 mm 12.598 in approx. |
ER-X032 | |||||
High and low temperature resistant |
ER-X032HC (Note 5) |
|||||
480 mm 18.898 in approx. |
ER-X048 | |||||
High and low temperature resistant |
ER-X048HC (Note 5) |
|||||
640mm 25.197 in approx. |
ER-X064 | |||||
High and low temperature resistant |
ER-X064HC (Note 5) |
Note 1: | Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge frequency 50 Hz and air supply 60 ℓ/min.(0.3 MPa). |
---|---|
Note 2: | Typical value in condition of discharge distance 100 mm 3.937 in (ER-X001: 50 mm 1.969 in), center of the product, discharge frequency 50 Hz (ER‑X□HC:30 Hz) and no air supply. |
Note 3: | Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON. |
Note 4: | The ER-X001 and ER-X008 must be combined with the new-type ER-XC02 controller (produced from April 2014 on). Refer to "Identification of previous-type and new-type controllers and for the combination with the head". |
Note 5: | The ER-X□HC high / low temperature resistant type head can be used under temperatures from -60 to +200 ℃ -76 to +392 ℉. Be sure to use this head in combination with the new-type controller, ER-XC02 (produced from April 2016 on). Refer to "Identification of previous-type and new-type controllers and for the combination with the head". |
Please order power cable or AC adapter separately.
Type | Appearance | Model No. | Number of heads connected |
Output |
---|---|---|---|---|
Standard type | ER-XC02 | Max. 2 units | PhotoMOS relay |
Head connection cable is not supplied with the head. Please order it separately.
Appearance | Model No. | Description | |
---|---|---|---|
ER-XCCJ2H | Length: 2 m 6.562 ft Net weight: 120 g approx. |
Cabtyre cable with both connector | |
ER-XCCJ5H | Length: 5 m 16.404 ft Net weight: 290 g approx. |
||
ER-XCCJ10H (Note) |
Length: 10 m 32.808 ft Net weight: 560 g approx. |
Note: Cannot be used with the high and low temperature resistant type head ER-X□HC.