Type | Spot type | Bar type | ||||
---|---|---|---|---|---|---|
Model No. | ER-X001 | ER-X008 | ER-X016 | ER-X032 | ER-X048 | ER-X064 |
Applicable regulations and certifications | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) | |||||
Effective charge removal width |
50 mm 1.969 in approx. |
80 mm 3.150 in approx. |
160 mm 6.299 in approx. |
320 mm 12.598 in approx. |
480 mm 18.898 in approx. |
640 mm 25.197 in approx. |
Charge removal time (±1,000 V→±100 V) |
0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2) |
1 sec. or less (Note 2) | ||||
Ion balance | ±30 V or less (Note 2, 3) | |||||
Discharge method | Pulse AC method | |||||
Discharge frequency | 50 Hz / 20 Hz | 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz |
100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz (Note 4) | |||
Discharge output voltage | ±7,000 V approx. | |||||
Ozone generation | 0.01 ppm or less (Note 2) | |||||
Maximum air pressure | 0.5 MPa | |||||
Applicable fluid | Air (dried clean air) (Note 5) | |||||
Operating altitude | 2,000 m 6561.68 ft or less (Note 6) | |||||
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (ER-X001: 0 to +40 ℃ +32 to +104 ℉) (No dew condensation), Storage: -10 to +65 ℃ +14 to +149 ℉ |
|||||
Ambient humidity | 35 to 65 % RH, Storage: 35 to 85 % RH | |||||
Vibration resistance | 10 to 55 Hz (ER-X001: 10 to 150 Hz) frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | |||||
Shock resistance | 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each | |||||
Enclosure grounding method | Floating | |||||
Material | Main unit enclosure: PPS, Stainless steal (SUS), Head mounting bracket: Stainless steal (SUS), Discharge needle: PC, PPS, Tungsten (Note 7) [ER-X001 – Main unit enclosure: Stainless steel (SUS), Head mounting bracket: Stainless steel (SUS), Discharge needle: PFA, Tungsten] |
|||||
Length of high-voltage cable | 1.2 m 3.937 ft | 0.5 m 1.640 ft | 0.5 m 1.640 ft (Note 4) | |||
Net weight | 370 g approx. | 330 g approx. | 410 g approx. | 530 g approx. | 650 g approx. | 780 g approx. |
Accessory | Head mounting bracket (mounted at the factory) |
Type | High and low temperature resistant | ||||
---|---|---|---|---|---|
Model No. | ER-X008HC | ER-X016HC | ER-X032HC | ER-X048HC | ER-X064HC |
Applicable regulations and certifications | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) | ||||
Effective charge removal width |
80 mm 3.150 in approx. |
160 mm 6.299 in approx. |
320 mm 12.598 in approx. |
480 mm 18.898 in approx. |
640 mm 25.197 in approx. |
Charge removal time (±1,000 V→±100 V) |
1 sec. or less (Note 2) | ||||
Ion balance | ±30 V or less (Note 2, 3) | ||||
Discharge method | Pulse AC method | ||||
Discharge frequency | 30 Hz (Note 8) | ||||
Discharge output voltage | ±7,000 V approx. | ||||
Ozone generation | 0.01 ppm or less (Note 2) | ||||
Maximum air pressure | 0.1 MPa | ||||
Applicable fluid | Air (dried clean air) (Note 5) | ||||
Operating altitude | 2,000 m 6561.68 ft or less (Note 6) | ||||
Ambient temperature | Head: -60 to +200 ℃ -76 to +392 ℉ (No dew condensation or icing) (Note 9), Storage: -10 to +65 ℃ +14 to +149 ℉ High voltage unit: 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: -10 to +65 ℃ +14 to +149 ℉ |
||||
Ambient humidity | 35 to 65 % RH, Storage: 35 to 85 % RH | ||||
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance | 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each | ||||
Enclosure grounding method | Floating | ||||
Material | Main unit enclosure: PPS, Stainless steal (SUS), Head mounting bracket: Stainless steal (SUS), Discharge needle: PC, PPS, Tungsten, Main unit enclosure of high-voltage unit: ABS |
||||
Length of high-voltage cable | Heat-resistant shielded cable, 1.8 m 5.906 ft | ||||
Net weight | 420 g approx. | 490 g approx. | 620 g approx. | 760 g approx. | 900 g approx. |
Accessories | ø6 ø0.236-4 Air tube joint: 1 pc., Seal cap: 1 pc., Head mounting bracket (mounted at the factory) |
Notes:
1) | Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge frequency 50 Hz and air supply 60 ℓ/min.(0.3 MPa). |
---|---|
2) | Typical value in condition of discharge distance 100 mm 3.937 in (ER-X001: 50 mm 1.969 in), center of the product, discharge frequency 50 Hz (ER‑X□HC:30 Hz) and no air supply. |
3) | Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON. |
4) | The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office. |
5) | The dried clean air is the air dried (dew point: equivalent of -20 ℃ -4 ℉) and filtered (mesh-size: equivalent of 0.01 μm). |
6) | Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
7) | Silicon needles (ER-X016S, ER-X032S and ER-XANS) are also available. For details, please contact our sales office. |
8) | Set the discharge frequency to 30 Hz. Do not use any other frequency. |
9) | Discoloration of the head may occur when used under high temperatures, but it does not affect the charge removal performance. |
When installing, make sure to expose a section measuring 500 mm 19.685 in or more to the normal temperature area as shown below for the protection of the high-voltage unit.
|
Type | Controller | |
---|---|---|
Model No. | ER-XC02 | |
Applicable regulations and certifications | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) | |
Number of heads connected | Maximum 2 units | |
Supply voltage | 24 V DC ±10 % | |
Current consumption | 450 mA or less when connecting 1 heads, 800 mA or less when connecting 2 heads | |
Indictor | Displays status of Head 1 and 2 | |
DSC (Discharge) | Green LED (lights up when discharging) | |
CHECK | Orange LED (lights up when dirt, wear, etc. of the discharge needle is detected) | |
ERROR | Red LED (lights up when abnormal discharge is detected) | |
Level meter | Green LED (5 levels, lights up depending on amount of the charge or ion generation) | |
Output [ALARM ERROR COM (Common)] |
PhotoMOS relay output • Maximum load current: 100 mA • Applied voltage: 30 V DC or less (between output-output common) • Residual voltage: 1.5 V or less (at load current of 100 mA) |
|
Output operation | ALARM: ON when dirt or wear of the discharge needle is detected; OFF when operation is normal. ERROR: OFF when abnormal discharge is detected; ON when operation is normal. |
|
Short-circuit protection | Incorporated (automatic reset type) | |
Discharge control input (DSC OFF) |
Discharge allowed: Open, Discharge halt: 24 V or 0 V shorted |
|
Contamination level | 2 | |
Overvoltage category | I | |
Elevation | 2,000 m 6561.68 ft or less (Note) | |
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: -10 to +65 ℃ +14 to +149 ℉ |
|
Ambient humidity | 35 to 65 % RH, Storage: 35 to 85 % RH | |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure 500 V AC for on min. between supply terminals and F.G. |
|
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | |
Enclosure grounding method | Floating | |
Material | Enclosure: ABS | |
Net Weight | 130 g approx. | |
Accessories | Power supply / I/O connector: 1 set (Housing 5557-10R, Terminal 5556TL [manufactured by Molex]) Ground wire (3.7 m 12.139 ft approx.): 1 pc. |
Note: Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]