Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100
I/O Circuit and Wiring diagrams
DPC-101
I/O circuit diagram
Notes:
1) |
Select and use the auto-reference function and remote zero-adjustment function. |
2) |
Set the output load resistance during analog current output to 250 Ω (max.) |
3) |
Note that a voltage of 5 V or higher is generated during analog current output. |
Symbols・・・ |
D1 to D4 : Reverse supply polarity protection diode ZD1 to ZD3 : Surge absorption zener diode Tr1, Tr2 : NPN output transistor |
For independent use of sensor head |
Notes:
1) |
In case the sensor head is used independently, insulate the white lead wire (terminal No.4) and keep it open. |
2) |
When the sensor head is used independently, devices connected to the analog output must have an input impedance set at 50 kΩ or more. |
Symbols・・・ |
D : Reverse supply polarity protection diode ZD: Surge absorption zener diode |
Terminal arrangement diagram
|
Connector for power supply / I-O cable (CN1) |
[1] +V [2] Analog voltage / current output [3] 0 V [4] Comparative output 1 [5] Comparative output 2 [5] External input (auto-reference function / remote zero-adjustment function)
Connector for sensor head (CN2) |
[1] Sensor head power supply [2] Analog voltage input [3] 0 V [4] Model discrimination signal |
DPC-101-P
I/O circuit diagram
Notes:
1) |
Select and use the auto-reference function and remote zero-adjustment function. |
2) |
Set the output load resistance during analog current output to 250 Ω (max.) |
3) |
Note that a voltage of +5 V or higher is generated during analog current output. |
Symbols・・・ |
D1 to D4 : Reverse supply polarity protection diode ZD1 to ZD3 : Surge absorption zener diode Tr1, Tr2: PNP output transistor |
For independent use of sensor head |
Notes:
1) |
In case the sensor head is used independently, insulate the white lead wire (terminal No.4) and keep it open. |
2) |
When the sensor head is used independently, devices connected to the analog output must have an input impedance set at 50 kΩ or more. |
Symbols・・・ |
D : Reverse supply polarity protection diode ZD: Surge absorption zener diode |
Terminal arrangement diagram
|
Connector for power supply / I-O cable (CN1) |
[1] +V [2] Analog voltage / current output [3] 0 V [4] Comparative output 1 [5] Comparative output 2 [6] External input (auto-reference function / remote zero-adjustment function)
Connector for sensor head (CN2) |
[1] Sensor head power supply [2] Analog voltage input [3] 0 V [4] Model discrimination signal |