Business
> Industrial Devices
> Automation Controls Top
> FA Sensors & Components
> Pressure Sensors / Flow Sensors
> Pressure Sensors / Flow Sensors
> Head-separated Dual Display Digital Pressure Sensor [For Gas] DPS-400 / DPH-100
> Specifications
Type | For compound pressure / vacuum pressure | For positive pressure | |
---|---|---|---|
Model No. | DPS-401 | DPS-402 | |
CE marking directive compliance | EMC Directive, RoHS Directive | ||
Applicable sensor head | Compound pressure : DPH-101□ Vacuum pressure : DPH-103□ |
Positive pressure : DPH-102□ | |
Rated pressure range | Compound pressure: -100.0 to +100.0kPa Vacuum pressure: 0 to -101kPa |
Positive pressure: 0 to +1.000MPa | |
Display / set pressure range | Compound pressure: –199.9 to +199.9 kPa Vacuum pressure: +101.3 to –101.3 kPa |
Positive pressure: –1.050 to +1.050 MPa | |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||
Power consumption (Note 2) |
Normal operation: 650 mW or less (Current consumption 25 mA or less at 24 V supply voltage) ECO mode: 500 mW or less (Current consumption 20 mA or less at 24 V supply voltage) |
||
Sensor head supply voltage | Same as supply voltage | ||
Sensor head input | Input voltage range: 1 to 5 V DC (over rated pressure range) | ||
Comparative outputs (Comparative output 1, 2) |
NPN open-collector transistor ・Maximum sink current: 50 mA (Note 3) ・Applied voltage: 30 V DC or less (between comparative output and 0 V) ・Residual voltage: 1.5 V or less (Note 4) [at 50 mA (Note 3) sink current] |
||
Output operation | NO / NC, selectable by jog switch | ||
Hysteresis | Minimum 0 digit, variable by hysteresis setting | ||
Repeatability | With compound pressure type connected: within ±0.2 % F.S. (±4 digits), With vacuum / positive pressure type connected: within ±0.2 % F.S. (±2 digits) | ||
Response time | 150 μs, 500 μs, 1 ms, 5 ms, 10 ms, 50 ms, 100 ms, 500 ms, selectable by jog switch | ||
Ambient temperature | –10 to +50℃ +14 to +122℉ (cascading 8 to 16 controllers: –10 to +45℃ +14 to +133℉) (No dew condensation or icing allowed), Storage: –20 to +70℃ –4 to +158℉ | ||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
Temperature characteristics | Over ambient temperature range –10 to +50℃ +14 to +122℉: within ±0.5 % F.S. of pressure at +25℃ +77℉ | ||
Material | Enclosure: Heat-resistant ABS, Protective cover: Polycarbonate, Jog switch: ABS, MODE key: Acrylic | ||
Weight | Net weight:20 g approx. |
Note 1: | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. |
---|---|
Note 2: | Excluding current consumption of the applicable pressure sensor head. |
Note 3: | 25 mA max. if 5 or more controllers are connected together. |
Note 4: | In case of using the quick-connection cable (cable length: 5 m 16.404 ft)(optional) |
Note 5: | The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below. Main cable (4-core): CN-74-C1 (cable length: 1m 3.281 ft), CN-74-C2 (cable length: 2 m 6.562 ft), CN-74-C5 (cable length: 5 m 16.404 ft) Sub cable (2-core): CN-72-C1 (cable length: 1m 3.281 ft), CN-72-C2 (cable length: 2 m 6.562 ft), CN-72-C5 (cable length: 5 m 16.404 ft) |
Note 6: | The values specified above are applied only to the controller. |
Type | Compound pressure | Positive pressure | Vacuum pressure | ||||||
---|---|---|---|---|---|---|---|---|---|
±100 kPa type | 1 MPa type | –101 kPa type | |||||||
Model No. (Note 3) |
DPH-101(-R) | DPH-101-M3(-R) | DPH-101-M5(-R) | DPH-102 | DPH-102-M5(-R) | DPH-103(-R) | DPH-103-M3(-R) | DPH-103-M5(-R) | |
CE marking directive compliance | EMC Directive, RoHS Directive | ||||||||
Type of pressure | Gauge pressure | ||||||||
Rated pressure range | –100.0 to +100.0 kPa | 0 to +1.000 MPa | 0 to –101.0 kPa | ||||||
Pressure withstandability | 500kPa | 1.5MPa | 500kPa | ||||||
Applicable fluid | Air, non-corrosive gas | ||||||||
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||||||||
Current consumption | 15 mA or less | ||||||||
Ambient temperature | 0 to +50℃ +32 to +122℉ (No dew condensation allowed), Storage: –10 to +60℃ +14 to +140℉ | ||||||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||||||
Temperature characteristics | Over ambient temperature range 0 to +50℃ +32 to +122℉: within ±2 % F.S. of detected pressure at +25℃ +77℉ | ||||||||
Material | Front case: PBT, Rear case: PBT (glass fiber reinforced), Pressure port: Stainless steel (SUS303), O-ring: NBR Pressure element: Silicon diaphragm, PPS |
||||||||
Cable | 0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable) | ||||||||
Cable extension | Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable. | ||||||||
Weight | Net weight | DPH-10□(-R): Head 10 g approx. / Cable 40 g approx., DPH-10□-M3/M5(-R): Head 6 g approx. / Cable 40 g approx. | |||||||
Gross weight | DPH-10□(-R): 80 g approx., DPH-10□-M3/M5(-R): 70 g approx. | ||||||||
Accessory | Connector (e-CON): 1 pc. (Note 4) |
Note 1: | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +25℃ +77℉. |
---|---|
Note 2: | The sensor head can be used independently. |
Note 3: | Model No. having the suffix "-R" is bending-resistant cable type. The bending-resistant cable type of DPH-102 is not available. |
Note 4: | Connectors (e-CON) are available as spare parts. CN-EP2: 5 pcs. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)