Digital Fiber Sensor FX-500 Ver.2

List of fibers

Response time of FX-500 series.

Mode HYPR U-LG LONG STD FAST H-SP
Response time 24ms or less 4ms or less 2ms or less 250μs or less 60μs or less 25μs or less

List of fiber

Square Head Fiber

■Thru-beam type(one pair set)

Type Model
No.
Sensing range(mm) (Note1)
HYPR U-LG LONG STD FAST H-SP
Square head M3 FT-R31 1,000 580 440 270 160 55
M4 FT-R43 3,000 1,600 1,100 720 430 130
FT-R41W 3,200 1,800 1,400 800 460 150
FT-R42W 3,600 (Note2) 3,600 (Note2) 3,500 2,200 1,300 460
FT-R44Y 3,000 1,600 1,100 720 430 130
M6 FT-R60Y 3,600 (Note2) 3,600 (Note2) 3,600 (Note2) 2,100 1,260 400
Note1:Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note2: The fiber cable length practically limits the sensing range.

■Reflective type

Type Model
No.
Sensing range(mm) (Note1) (Note2)
HYPR U-LG LONG STD FAST H-SP
Square head M3 FD-R31G 530 310 260 170 85 27
FD-R32EG 170 110 92 45 30 9
FD-R34EG 130 90 70 38 23 7
FD-R33EG 84 44 33 19 11 3
M4 FD-R41 710 430 320 210 100 34
M6 FD-R61Y 990 610 435 280 160 50
Note1:Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note2: The sensing range is specified for white non-glossy paper.

For details of Square Head Fiber, refer to product information page.
>>Go to "Square Head Fiber"

Return to top

Super Quality

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm)
HYPR U-LG LONG STD FAST H-SP
Threaded M3 FT-30 1,350 810 650 400 210 75
M4 FT-40 3,600 (Note) 2,200 1,700 1,200 530 190
Cylindrical φ1.5 FT-S20 1,350 810 650 400 210 75
φ3 FT-S30 3,600 (Note) 2,200 1,700 1,200 530 190
Note:The fiber cable length practically limits the sensing range.

■Reflective type

Type Model No. Sensing range (mm) (Note)
HYPR U-LG LONG STD FAST H-SP
Threaded M3 FD-30 600 330 250 160 80 25
M4 FD-40 600 330 250 160 80 25
M6 FD-60 1,550 900 740 520 260 90
Cylindrical φ3 FD-S30 600 330 250 160 80 25
Note:The sensing range is specified for white non-glossy paper.

For details of Super Quality Fiber, refer to product information page.
>>Go to "Super Quality Fiber"

Return to top

Threaded Type

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm) (Note 1)
HYPR U-LG LONG STD FAST H-SP
Threaded M3 FT-31 1,350 770 550 315 210 70
FT-31W 990 590 440 260 150 53
FT-32 3,600
(Note 2)
3,600
(Note 2)
3,600
(Note 2)
3,000 1,600 580
M4   FT-43 3,600
(Note 2)
2,800 2,100 1,400 770 240
FT-42 3,600
(Note 2)
2,050 1,600 1,130 530 190
FT-42W 3,300 1,900 1,400 800 490 160
FT-45X 1,600
(Note 2)
1,600
(Note 2)
1,600
(Note 2)
1,200 630 200
Elbow FT-R40 3,600
(Note 2)
1,750 1,500 930 500 160
M14 Long range FT-140 19,600
(Note 2)
19,600
(Note 2)
19,600
(Note 2)
19,600
(Note 2)
16,000 6,300
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Threaded M3   FD-31 515 290 220 125 80 25
FD-31W 330 180 140 80 45 12
FD-32G 650 380 270 200 95 27
FD-32GX 630 410 360 200 100 30
FD-34G 330 185 135 90 49 15
Ultra-small diameter FD-EG30 170 130 110 48 30 9
FD-EG31 85 45 35 20 12 3.5
M4 FD-41 515 290 220 125 80 25
FD-41W 900 630 430 270 150 45
FD-42G 650 380 270 200 95 27
FD-42GW 670 340 280 150 90 25
M6   FD-62 1,500 1,000 940 520 340 110
FD-61 1,400 840 670 450 200 70
FD-61W 900 630 430 270 150 45
FD-61G 1,100 800 650 420 200 60
FD-64X 670 500 410 280 160 50
Elbow FD-R60 1,100 600 550 290 190 65
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.

For details of Threaded Type Fiber, refer to product information page.
>>Go to "Threaded Type Fiber"

Return to top

Cylindrical Type

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm) (Note 1)
HYPR U-LG LONG STD FAST H-SP
Cylindrical φ1 FT-S11 350 210 160 90 60 19
φ1.5 FT-S21 1,350 770 550 315 210 70
FT-S21W 990 590 440 260 150 53
FT-S22 1,500 920 730 450 250 90
φ2.5 FT-S32 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,100 1,800 600
φ3 FT-S31W 3,300 1,900 1,400 800 490 160
Ultra-small diameter φ3 FT-E13 52 30 24 15 8 2
FT-E23 270 160 125 75 42 13
Side-view φ4 FT-V40 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,500 2,400 850
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Cylindrical φ1.5 FD-S21 190 130 110 80 37 11
φ3 FD-S32 1200 790 660 420 220 75
FD-S32W 900 630 430 270 150 45
FD-S31 515 290 220 125 80 25
FD-S33GW 670 340 280 150 90 25
FD-S34G 330 185 135 90 49 15
Ultra-small diameter φ1.5 FD-E13 50 29 25 12 7 2
φ3 FD-E23 170 120 80 55 30 9
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.

For details of Cylindrical Type Fiber, refer to product information page.
>>Go to "Cylindrical Type Fiber"

Return to top

Sleeve

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Threaded M3 FT-31S 1,220 740 550 315 195 63
M4 FT-42S 3,600 (Note 2) 2,050 1,600 1,130 530 190
Cylindrical Ultra-small diameter φ3 FT-E13 52 30 24 15 8 2
FT-E23 270 160 125 75 42 13
Side-view φ2 FT-V23 1,800 1,000 880 450 280 90
FT-V25 900 550 480 240 140 45
FT-V24W 380 230 200 110 60 20
φ2.5 FT-V30 2,200 1,200 1,000 680 340 100
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Threaded Ultra-small diameter M3 FD-EG30S 170 110 80 50 30 9
M4 FD-41S 515 290 220 125 80 25
FD-41SW 330 180 140 80 45 12
M6 FD-61S 1,200 790 660 420 220 75
Cylindrical Ultra-small diameter φ1.5 FD-E13 50 29 25 12 7 2
φ3 FD-E23 170 120 80 55 30 9
Side-view φ3 FD-V30 240 130 120 65 35 14
FD-V30W 80 40 30 20 10 2
φ5 FD-V50 370 220 210 120 75 25
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.

For details of Sleeve Fiber, refer to product information page.
>>Go to "Sleeve Fiber"

Return to top

Flat Type

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm) (Note 1)
HYPR U-LG LONG STD FAST H-SP
Flat   FT-Z30H 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,500 2,600 810
FT-Z30HW 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,500 2,600 810
FT-Z30E 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,500 2,400 740
FT-Z30EW 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,400 2,000 630
FT-Z30 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 2,100 1,200 410
FT-Z30W 3,600 (Note 2) 3,300 3,200 1,500 1,000 280
With boss FT-Z20W 1,600 (Note 2) 1,500 1,100 620 420 130
FT-Z20HBW 1,100 670 570 260 180 55
FT-Z40W 3,600 (Note 2) 3,300 2,300 1,500 900 290
FT-Z40HBW 3,300 1,900 1,400 800 490 160
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Flat With boss FD-Z20W 260 150 130 1 to 65 2 to 45 5 to 13
FD-Z20HBW 1 to 340 1 to 210 1 to 180 2 to 85 2 to 55 3 to 15
FD-Z40W 790 440 390 190 1 to 120 2 to 35
FD-Z40HBW 760 540 470 260 1 to 160 2 to 50
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.

For details of Flat Type Fiber, refer to product information page.
>>Go to "Flat Type Fiber"

Return to top

Narrow Beam

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm) (Note 1)
HYPR U-LG LONG STD FAST H-SP
Narrow beam FT-KS40 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 1,200
FT-KV40 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 1,200
FT-KV40W 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,100 940
FT-KV26 2,500 1,600 1,200 710 440 160
FT-KV26H1 2,200 1,430 1,070 630 390 135
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.

■Retroreflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
With polarizing filters FR-Z50HW 100 to 1,900 100 to 1,400 100 to 1,200 100-990 100 to 780 100 to 490
Wafer mapping FR-KZ22E 15 to 570 15 to 460 15 to 410 15 to 310 15 to 220 15 to 100
Narrow beam Top sensing FR-KZ50H 20 to 1,000 20 to 800 20 to 400 20 to 300 20 to 200 20 to 200
Side sensing FR-KZ50E 20 to 1,000 20 to 800 20 to 400 20 to 300 20 to 200 20 to 200
Note 1: Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2: The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

■Reflective type

Type Model No. Sensing range (mm) (Note)
HYPR U-LG LONG STD FAST H-SP
Long range FD-Z50HW 10 to 2,500 10 to 1,100 10 to 1,000 10 to 650 10 to 410 15 to 130
Note: Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Narrow Beam Fiber, refer to product information page.
>>Go to "Narrow Beam Fiber"

Return to top

Wide Beam

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm) (Note 1)
HYPR U-LG LONG STD FAST H-SP
Wide beam FT-A32 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 2,100
FT-A32W 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,000
FT-A11 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 1,100
FT-A11W 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 1,300
Array FT-AL05 2,300 1,550 1,500 860 500 170
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2: The fiber cable length practically limits the sensing range to 3,600 mm long.

■Reflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Wide beam FD-A16 - 200 200 200 140 75
Array FD-AL11 670 530 510 320 180 50
Note 1: Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2: The sensing range is specified for white non-glossy paper.

For details of Wide Beam Fiber, refer to product information page.
>>Go to "Wide Beam Fiber"

Return to top

Convergent Reflective Type

■Reflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Glass substrate detection FD-L32H 0 to 110 0 to 87 0 to 74 0 to 56 1 to 38 -
FD-L30A 0 to 43 0 to 43 0 to 43 0 to 43 0 to 42 0 to 29
FD-L31A 3 to 35 4 to 33 4 to 33 4 to 33 4 to 32 5 to 25
FD-L22A 0 to 31 0 to 28 0 to 27 0 to 24 0 to 24 0 to 18
FD-L23 0 to 30 0 to 30 0 to 30 0 to 29 0 to 28 1.5 to 24
FD-L11 0 to 11.5 0 to 10.5 0 to 10 0 to 9.5 0 to 9 0 to 8
FD-L10 0 to 6 0 to 5.5 0 to 5.5 0 to 5 0 to 4.5 0 to 4
FD-L21 1 to 19 1 to 18 1 to 18 1.5 to 16 2 to 15 3 to 12
FD-L21W 1.5 to 15 2 to 15 2 to 15 3 to 14 4 to 14 6.5 to 10
General purpose FD-L20H 0 to 45 0 to 35 0 to 32 0 to 23 2 to 15 5 to 9
Ultla-small FD-L12W 0 to 14 0 to 12.5 0 to 12 0 to 8 0.5 to 7 0.5 to 4
Note 1: The sensing range is specified for transparent glass 100 x 100 x t0.7 mm (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm).
Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Convergent Reflective Type Fiber, refer to product information page.
>>Go to "Convergent Reflective Type Fiber"

Return to top

Retroreflective Type

■Retroreflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
With polarizing filters FR-Z50HW 100 to 1,900 100 to 1,400 100 to 1,200 100 to 990 100 to 780 100 to 490
Wafer mapping FR-KZ22E 15 to 570 15 to 460 15 to 410 15 to 310 15 to 220 15 to 100
Narrow beam Top sensing FR-KZ50H 20 to 1,000 20 to 800 20 to 400 20 to 300 20 to 200 20 to 200
Side sensing FR-KZ50E 20 to 1,000 20 to 800 20 to 400 20 to 300 20 to 200 20 to 200
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.

For details of Retroreflective Type Fiber, refer to product information page.
>>Go to "Retroreflective Type Fiber"

Return to top

Chemical-resistant

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm) (Note 1)
HYPR U-LG LONG STD FAST H-SP
Chemical-resistant FT-Z802Y 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,100 1,900 470
FT-HL80Y 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 2,300 740
FT-L80Y 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 3,600 (Note 2) 2,800 920
FT-V80Y 3,600 (Note 2) 2,800 2,200 1,300 800 240
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

Type Model No. Sensing range (mm) (Note1)(Note2)
HYPR U-LG LONG STD FAST

H-SP

Chemical-resistant FD-S60Y 600 590 420 320 200 75
Note 1: Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.

For details of Chemical-resistant Fiber, refer to product information page.
>>Go to "Chemical-resistant Fiber"

Return to top

Heat-resistant

■Thru-beam type (one pair set)

Type Heat-resistant
temp.
Model No. Sensing range (mm) (Note 1)
HYPR U-LG LONG STD FAST H-SP
Heat-resistant 350℃ FT-H35-M2 1,200 880 670 430 250 80
FT-H35-M2S6 1,200 880 670 430 250 80
200℃ FT-H20W-M1 1,600 (Note 2) 1,000 840 470 300 90
FT-H20-M1 1,600 (Note 2) 1,300 960 540 330 110
130℃ FT-H13-FM2 3,300 1,900 1,300 700 410 140
Heat-resistant (joint) 200℃ FT-H20-J20-S 1,600 1,000 790 470 300 90
FT-H20-J30-S 1,600 1,000 790 470 300 90
FT-H20-J50-S 1,600 1,000 790 470 300 90
FT-H20-VJ50-S 2,100 1,300 980 600 390 120
FT-H20-VJ80-S 2,100 1,300 980 600 390 120
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The fiber cable length practically limits the sensing range.

■Reflective type

Type Heat-resistant
temp.
Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Heat-resistant Threaded 350℃ FD-H35-M2 720 540 460 260 150 45
FD-H35-M2S6 720 540 460 260 150 45
FD-H35-20S 840 550 440 260 140 45
200℃ FD-H20-M1 840 550 500 330 200 55
FD-H20-21 770 500 380 230 130 45
130℃ FD-H13-FM2 880 640 600 350 200 65
Glass substrate detection convergent reflective 300℃ FD-H30-L32 0 to 40 0 to 30 0 to 25 0 to 17 0 to 12 1.5 to 6
250℃ FD-H25-L43 1 to 31 1 to 30 1 to 28 1.5 to 26 1.5 to 24 2 to 18
FD-H25-L45 4 to 43.5 4 to 43 4.5 to 43 5 to 42 5 to 40 6.5 to 34
180℃ FD-H18-L31 0 to 60 0 to 32 0 to 24 0 to 16 0 to 13 2 to 6.5
Note 1: The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm glass substrate for FD-H30-L32 and FD-H18-L31, transparent glass 100 x 100 x t0.7 mm for FD-H25-L43 and FD-H25-L45).
Note 2:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of Heat-resistant Fiber, refer to product information page.
>>Go to "Heat-resistant Fiber"

Return to top

One-Touch Connection System Vacuum-resistant Fibers NEW

■Thru-beam type

Type Model No. Sensing range (mm)(Note 1)
HYPR U-LG LONG STD FAST H-SP
Vacuum-
resistant
Thru-beam FT-40V 1,000 590 470 270 160 55
(Note 1): Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

Type Model No. Sensing range(mm) (Note 1)(Note 2)
HYPR U-LG LONG STD FAST H-SP
Vacuum-
resistant
Long range
reflective
FD-KZ50V 5 to 500 10 to 340 15 to 270 20 to 200 20 to 120 20 to 45
Convergent
reflective
FD-L10V 0 to 18 0 to 12 0 to 10 0 to 8 0 to 5.5 1.5 to 3
(Note 1): The sensing range is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in.
(Note 2): Atmospheric side fiber, FT-J9 (optional) is free-cut type.
Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

For details of One-Touch Connection System Vacuum-resistant Fibers, refer to product information page.
>>Go to "One-Touch Connection System Vacuum-resistant Fibers"

Return to top

Vacuum-resistant

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm)
HYPR U-LG LONG STD FAST H-SP
Vacuum-resistant Thru-beam FT-H30-M1V-S 1,000 590 470 270 160 55

■Reflective type

Type Model No. Sensing range (mm) (Note)
HYPR U-LG LONG STD FAST H-SP
Vacuum-resistant Reflective FD-H30-KZ1V-S 5 to 500 10 to 340 15 to 270 20 to 200 20 to 120 20 to 45
Convergent reflective FD-H30-L32V-S 0 to 18 0 to 12 0 to 10 0 to 8 0 to 5.5 1.5 to 3
Note: The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm.

For details of Vacuum-resistant Fiber, refer to product information page.
>>Go to "Vacuum-resistant Fiber"

Return to top

Discontinued products

Metal-free

■Thru-beam type (one pair set)

Type Model No. Sensing range (mm) (Note)
HYPR U-LG LONG STD FAST H-SP
Threaded M4 FT-41 3,300 2,000 1,550 1,100 445 150
Note:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

■Reflective type

Type Model No. Sensing range (mm) (Note 1, 2)
HYPR U-LG LONG STD FAST H-SP
Threaded M4 FD-G40 550 330 270 140 80 27
M6 FD-G60 1,400 800 650 420 200 60
Note 1:Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Note 2:The sensing range is specified for white non-glossy paper.

For details of Metal-free Fiber, refer to product information page.
>>Go to "Metal-free Fiber"

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)