【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Photoelectric Sensors / Laser Sensors > CMOS type Micro Laser Distance Sensor HG-C > Cautions For Use
|
・ | This website is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. |
---|
* | This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
---|
IEC | : IEC 60825-1:2014 | |
EN | : EN 60825-1:2014/A11:2021 | |
JIS | : JIS C 6802:2014 | |
GB | : GB 7247.1-2012 | |
KS | : KS C IEC 60825-1:2014 | |
FDA | : PART 1040.10, 1040.11(Laser Notice No.56 applied) |
These standards classifies laser products according to the level of hazard and provide the safety measures for respective classes. Based on the above standards, HG-C series is classified as a Class 2 laser product. |
---|
Classification | Summary of hazard evaluation |
---|---|
Class 2 | A laser that emits visible light with the wavelength range of 400 nm to 700 nm under which eyes can be protected by an aversive reaction (Avoidance behavior) such as a blink. |
Note: When an unexpected failure occurs, dangerous radiation may be generated. Therefore, pay special attention to safety.
Part description |
Item | Default setting | Description |
---|---|---|
Response time setting | Set the response time. : High precision 10ms, : Standard 5ms : High speed1.5ms |
|
Output operation setting | Select the control output operation mode. : Light-ON, : Dark-ON |
|
Sensing output setting | Set the sensing output. : Normal sensing mode : 1-point teaching (Window comparator mode) : 2-point teaching (Window comparator mode) : 3-point teaching (Window comparator mode) : Rising differential mode : Trailing differential mode |
|
Analog output setting | Sets the output operation of analog output setting. :Analog voltage output (0 to +5V) :Analog current output (4 to 20mA) |
|
Hysteresis setting | Set the hysteresis width. HG-C1030 : 0.001 to 5.00mm 0.00004 to 0.197 in HG-C1050 : 0.01 to 15.00mm 0.00039 to 0.591 in HG-C1100 : 0.02 to 35.00mm 0.00079 to 1.378 in HG-C1200 : 0.1 to 80.0 mm 0.00394 to 3.150 in HG-C1400 : 0.2 to 200.0 mm 0.00787 to 7.874 in |
|
External input setting | Set the external input. : Zero set function, : Teaching function : Light emitting stop function, :Trigger function |
|
Timer setting | Set the timer operation. The timer time is fixed at 5ms. : No timer, : Teaching function : Light emitting stop function, : Trigger function |
|
Display setting | The display of the measured value can be changed. : Normal, : Invert, : Offset |
|
Hold setting | Set the control output and the analogue output operation when a measurement error occurs (insufficient light intensity, saturation of light
intensity, out of measurement range). : Hold OFF, : Hold ON |
|
ECO setting | The digital display can be set to go OFF when key operation is not performed for 30 seconds. Current consumption can be reduced. : ECO OFF : ECO ON |
|
Reset setting | Return to the default setting (factory setting). : Reset NG, : Reset OK |
Note: | Due to the simple mounting bracket, the sensing characteristics may not be hold depending on the installation condition, in case of the purposes for acquiring the displacement data and a fine detecting. |
---|
Mounting direction |
|
|
|
|
|
・In case of errors, attempt the following measures.
Error indication | Description | Remedy |
---|---|---|
Insufficient amount of reflected light. The sensing object is out of the sensing range. |
Confirm that the sensing distance is within the specification range. Adjust the installation angle of the sensor. |
|
Flash memory is damaged or is past its life expectancy. | Please contact our office. | |
Load of the sensing output is short-circuited causing an over-current to flow. | Turn OFF the power and check the load. | |
The semiconductor laser is damaged or is past its life expectancy. | Please contact our office. | |
・When zero set is set, the measurement is not performed normally. ・Since the display setting is set to “Offset”, the zero set function can not be used. |
・Confirm that the sensing distance is within the specification range. ・Set the display to any setting except “Offset.” |
|
During teaching, the measurement is not performed normally. | Confirm that the sensing distance is within the specification range. | |
System error | Please contact our office. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)