【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.

AUTOMATION
CONTROLS

Search
Discontinued
Products



Compact & Long Range Laser Distance Sensor HG-F1

Specifications

Type NPN output type PNP output type
Model No. HG-F13A-A-N HG-F13A-A-P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, TÜV SÜD certification (USA, Canada)
Measurable range 250 to 3,000 mm 9.843 in to 118.110 in
Displayable range (Note 2) 200 to 3,300 mm 7.874 in to 129.921 in
Repeatability 10 mm 0.394 in or less (target object: sheet of white non-glossy paper measuring 200 × 200 mm 7.874 × 7.874 in)
Hysteresis 30 mm 1.181 in (default setting) Possible to vary up to 1 mm 0.039 in minimum in the PRO mode (Note 3)
Linearity ± 2% F.S. (Note 4) (at a measuring distance of 500 mm to 3,000 mm 19.685 in to 118.110 in)
Temperature characteristics 0.1% F.S./℃
Light source Red semiconductor laser: Class 1 [IEC / EN / JIS / GB / KS / FDA(Note 5)]
Maximum output: 0.39 mW, Peak emission wavelength: 680 nm 0.0268 mil
Beam diameter (Note 6) Approx. ø10 mm ø0.394 in (typical) (at the measuring distance of 1,000 mm 39.370 in)
Supply voltage 24 V DC ±10%, Ripple P-P 10%
Power consumption (Note 7) 40 mA or less (at 24 V DC supply voltage)
Control output NPN open-collector transistor
• Maximum sink current: 50 mA
• A pplied voltage: 30 V DC or less (Between control output to 0 V)
• Residual voltage: 1.5 V or less (At 50 mA sink current)
• Leakage current: 0.1 mA or less
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (Between control output to +V)
• Residual voltage: 1.5 V or less (At 50 mA source current)
• Leakage current: 0.1 mA or less
  Output
operation
Switchable between Light-ON / Dark-ON, (Default: Light-ON)
Short-circuit
protection
Incorporated (Auto reset type)
Analog output Switchable between voltage output / current output (Default: voltage output)
  Analog
voltage
output
Output range(Note 9) • In normal operation: 0 to +5 V Possible to set the distance range (Default: 250 to 3,000 mm 9.843 in to 118.110 in)
• When alarm occurs: Last value is held or the range is set to 0 V on the near point side and to +5.2 V on the far point side.
Output
impedance
100 Ω
Analog
current
output
Output range(Note 9) • In normal operation: +4 to +20 mA Possible to set the distance range (Default: 250 to 3,000 mm 9.843 in to 118.110 in)
• When alarm occurs: Last value is held or the range is set to 0 mA on the near point side and to +20.8 mA on the far point side.
Output
impedance
250 Ω or less
Response time Switchable between 35 ms / 100 ms / 300 ms / 2,000 ms (Default: 100 ms)
External input NPN non-contact input
• Input condition
Invalid: +8 to + V DC or Open
Valid: 0 to +1.2 V DC
• Input impedance: approx. 10 kΩ
PNP non-contact input
• Input condition
Invalid: 0 to +0.6 V DC or Open
Valid: +4 to +V DC
• Input impedance: approx. 10 kΩ
External input function Switchable between zero set, teaching, or emission stop (Default: zero set)
Teaching function Switchable between normal sensing mode (2-point / limit) or window comparator mode (1-point / 2-point / 3-point)
(Default: Normal sensing mode)
Timer function Switchable between OFF / ON delay / OFF delay / one-shot (Default: OFF)
Timer period Switchable between 5 ms / 10 ms / 25 ms / 50 ms / 100 ms / 250 ms / 500 ms / 1,000 ms / 5,000 ms (Default: 5 ms)
Pollution degree 2
Overvoltage category Category I
Ambient altitude (Note 8) 2,000 m 6561.680 ft or less
Environmental
resistance
Protection IP67 (IEC)
Ambient temperature -10 to +45 ℃ +14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (approx. 50 G) in X, Y and Z directions three times each
Cable 0.2 mm2 5-core composite cable, 2 m 6.562 ft long
Cable extension Extension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable
Material Enclosure: Aluminum die-cast, Front cover: Acrylic, Cable: PVC
Weight Net weight: approx. 85 g, Gross weight: approx. 130 g

Notes:

1) Unless otherwise specified, measurement conditions are as follows: Power supply voltage of 24 VDC, ambient temperature of +20 ℃ +68 ℉, response time of 100 ms, and measuring distance of 1,000 mm 39.370 in. The target object is a 200 mm × 200 mm 7.874 in ×7.874 in white non-glossy paper.
Perform measurement 30 minutes after turning on the power supply.
2) When an object is detected, the range of numerical values that appear on the digital display is regarded as the displayable distance. When zero setting is performed, the displayable distance varies depending on the zero setting distance.
3) Changing the hysteresis may result in unstable sensing. After making a change, perform operation check using actual equipment.
4) F.S. (full scale) represents a range from 0 mm to 3,000 mm 0 in to 118.110 in.
5) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
6) The beam diameter is defined as 1/e2 (approx. 13.5%) of the center light intensity. Due to leak light outside the defined range, the measurement values may be affected if the reflectance around the detecting point is higher than that of the detecting point.
7) Analog output is not included.
8) Do not use or store this product in environments where ambient air is pressurized to an air pressure higher than the atmospheric pressure at an altitude of 0 m.
9) When the intensity of received light is unstable, the voltage is output as 0 V and the current is output as 0 mA.

Regulations and Standards

■ Conforming directives and conforming regulations

EU Regulations: EMC Directive 2014/30/EU
UK Regulations: EMC Regulations 2016/1091

● Applicable standards

  • EN 61000-6-4
  • EN 61000-6-2
  • EN 60825-1
USA regulations: FDA21 CFR1040.10, and 1040.11 (Laser Notice No.56 applied)

■ Conforming standards

● USA/Canada Standards

  • UL 61010-1
  • CAN/CSA No.61010-1

● Other standards

  • IEC 60825-1
  • JIS C 6802
  • GB 7247.1
  • KS C IEC 60825-1

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)