Type (Note 2) | Standard / PNP output | Standard / NPN output | Sub | |
---|---|---|---|---|
Model | SG-P□-M-P | SG-P□-M-N | SG-P□-S | |
Applicable standards | International standards | ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119 | ||
Japan | JIS B 9705-1, JIS C 0508 1 to 7, JIS B 9961, JIS C 8201-5-2, JIS B 9710 | |||
Europe (EU) | EN ISO 13849-1 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1 | |||
North America | CAN/CSA C22.2 No.14, UL508 | |||
Applicable standards and certifications | CE Marking (Machinery Directive, RE Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification (U.S.A., Canada), the U.S.'s radio regulations (FCC), Canada's radio regulations (ICES-003, RSS-310), Singapore's radio regulations (IMDA) | |||
Operating distance | Front / Side | Sao (OFF→ON): 5 mm 0.197 in, Sar (ON → OFF): 15 mm 0.591 in | ||
Power supply voltage | 24V DC+10-20% Ripple P-P 10 % or less | |||
Current consumption | 30 mA or less | 20 mA or less | ||
Control output (OSSD1, OSSD2) (Note 3) |
PNP open-collector transistor 2 outputs • Maximum source current: 100 mA |
NPN open-collector transistor 2 outputs • Maximum sink current: 100 mA |
— | |
• Applied voltage: Same as the power supply voltage (PNP output: between control output and 0 V, NPN output: between control output and +V) • Residual voltage: 2 V or less (source current and sink current: 100 mA) (excluding voltage drop due to cable) • Leakage current: 0.2 mA or less (including power OFF state) • Maximum load capacity: 0.47 μF • Load wiring resistance: 3 Ω or less |
— | |||
Operation mode (Output operation) |
• When the actuator is detected (safe state): ON • When the actuator is not detected (unsafe state or lockout state): OFF • When the switch body (sub) does not detect actuator (series connection): OFF |
— | ||
Protection circuit (Short-circuit protection) | Incorporated | — | ||
Response time | • For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less • For multiple units: Time for single unit + 5 ms × (number of connected units - 1) |
|||
Check input and output | Dedicated communication line between the switch body (standard) and the switch body (sub) (Note 4) * It is not for external input and output. (voltage range 0 V to 5 V DC) |
|||
Number of units connected in series | 30 units or less (standard 1 unit, sub 29 units) | |||
Pollution degree | 3 | |||
Environmental resistance |
Protection | IP65(IEC) | ||
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +65 ℃ -13 to +149 ℉ | |||
Ambient humidity | 30 to 85 % RH, Storage: 30 to 95 % RH | |||
Voltage withstandability | 1,000 V AC for one minute between all supply terminals connected together and enclosure | |||
Insulation resistance | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure | |||
Vibration resistance | 10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions | |||
Shock resistance | 300 m/s2 (approx. 30 G), 3 times each in X, Y, and Z direction | |||
Material | Switch body: PBT, PC, SUS (stainless steel), EPDM Actuator: PBT, PC (Only visible type) |
|||
Cable | 6–core cabtyre cable, 5 m 16.404 ft long | 4–core cabtyre cable, 3 m 9.843 ft long | ||
Connected cable length | • When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit • When connecting multiple units in series: Maximum total cable length of 100 m 328.084 ft, maximum cable length of 20 m 65.617 ft between two adjacent units |
|||
Weight | • Compact type Switch body (standard): 180 g approx., Switch body (sub): 110 g approx., Actuator: 10 g approx. • Visible type Switch body (standard): 180 g approx., Switch body (sub): 120 g approx., Actuator : 20 g approx. |
|||
Gross weight | • Compact type SG-P□10-M-□: 260 g approx., SG-P□10-S: 190 g approx. • Visible type SG-P□20-M-□: 270 g approx., SG-P□20-S: 210 g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃ +73 ℉. |
---|---|
2) | Sub units cannot be used alone. When using a single unit, use a standard unit. When using multiple units in series connection, combine a standard unit with sub units. |
3) | Provided only on the standard unit. |
4) | When using the device as a single unit, connect the check input with the check output. |
■ | Transponder specifications Operating frequency: 125 kHz Max. transmitter output: 3.33 μW |
---|