Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Non-Contact Safety Door Switch SG-P > Specifications
|
Type (Note 2) | Standard / PNP output | Standard / NPN output | Sub | |
---|---|---|---|---|
Model | SG-P□-M-P | SG-P□-M-N | SG-P□-S | |
Applicable standards | International standards | ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119 | ||
Japan | JIS B 9705-1, JIS C 0508-1 to 3 (SIL3), JIS B 9961, JIS C 8201-5-2, JIS B 9710 | |||
Europe | EN ISO 13849-1:2015 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1 | |||
North America | CAN/CSA C22.2 No.14, UL508 | |||
Applicable standards and certifications | CE Marking (Machinery Directive, RE Directive, RoHS Directive), UKCA Marking (Supply of Machinery (Safety) Regulations, RE Regulations, RoHS Regulations), TÜV SÜD certification, TÜV SÜD certification (U.S.A., Canada), the U.S.'s radio regulations (FCC) (Note 5), Canada's radio regulations (ICES-003, RSS-310) (Note 5), Singapore's radio regulations (IMDA certification) (Note 5), Thailand's radio regulations (NBTC certification) (Note 5), Korea's radio regulations (KC certification) (Note 5), India's radio regulations (WPC certification) (Note 5) | |||
Operating distance | Front / Side | Sao (OFF→ON): 5 mm 0.197 in, Sar (ON → OFF): 15 mm 0.591 in | ||
Power supply voltage | 24V DC+10-20% Ripple P-P 10 % or less | |||
Current consumption | 30 mA or less | 20 mA or less | ||
Control output (OSSD1, OSSD2) (Note 3) |
PNP open-collector transistor 2 outputs • Maximum source current: 100 mA |
NPN open-collector transistor 2 outputs • Maximum sink current: 100 mA |
— | |
• Applied voltage: Same as the power supply voltage (PNP output: between control output and 0 V, NPN output: between control output and +V) • Residual voltage: 2 V or less (source current and sink current: 100 mA) (excluding voltage drop due to cable) • Leakage current: 0.2 mA or less (including power OFF state) • Maximum load capacity: 0.47 μF • Load wiring resistance: 3 Ω or less |
— | |||
Operation mode (Output operation) |
• When the actuator is detected (safe state): ON • When the actuator is not detected (unsafe state or lockout state): OFF • When the switch body (sub) does not detect actuator (series connection): OFF |
— | ||
Protection circuit (Short-circuit protection) | Incorporated | — | ||
Response time | • For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less • For multiple units: Time for single unit + 5 ms × (number of connected units - 1) |
|||
Check input and output | Dedicated communication line between the switch body (standard) and the switch body (sub) (Note 4) * It is not for external input and output. (voltage range 0 V to 5 V DC) |
|||
Number of units connected in series | 30 units or less (standard 1 unit, sub 29 units) | |||
Pollution degree | 3 | |||
Environmental resistance |
Protection | IP65(IEC) | ||
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +65 ℃ -13 to +149 ℉ | |||
Ambient humidity | 30 to 85 % RH, Storage: 30 to 95 % RH | |||
Voltage withstandability | 1,000 V AC for one minute between all supply terminals connected together and enclosure | |||
Insulation resistance | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure | |||
Vibration resistance | 10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions | |||
Shock resistance | 300 m/s2 (approx. 30 G), 3 times each in X, Y, and Z direction | |||
Material | Switch body: PBT, PC, SUS (stainless steel), EPDM Actuator: PBT, PC (Only visible type) |
|||
Cable | 6–core cabtyre cable, 5 m 16.404 ft long | 4–core cabtyre cable, 3 m 9.843 ft long | ||
Connected cable length | • When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit • When connecting multiple units in series: Maximum total cable length of 100 m 328.084 ft, maximum cable length of 20 m 65.617 ft between two adjacent units |
|||
Weight | • Compact type Switch body (standard): 180 g approx., Switch body (sub): 110 g approx., Actuator: 10 g approx. • Visible type Switch body (standard): 180 g approx., Switch body (sub): 120 g approx., Actuator : 20 g approx. |
|||
Gross weight | • Compact type SG-P□10-M-□: 260 g approx., SG-P□10-S: 190 g approx. • Visible type SG-P□20-M-□: 270 g approx., SG-P□20-S: 210 g approx. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃ +73 ℉. |
---|---|
2) | Sub units cannot be used alone. When using a single unit, use a standard unit. When using multiple units in series connection, combine a standard unit with sub units. |
3) | Provided only on the standard unit. |
4) | When using the device as a single unit, connect the check input with the check output. |
5) | This product uses a weak radio signal for its detection operation. Please confirm compliance with applicable laws in the country of use. |
■ | Transponder specifications Operating frequency: 125 kHz Max. transmitter output: 3.33 μW |
---|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)