Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > UV-Curing Systems > UV-Curing Systems > Aicure UJ30/35 LED Spot Type UV Curing Systems(Discontinued Products) > How to read UV intensity data
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
|
When ANUJ6160 and ANUJ6423 are used in combination, the peak intensity in the center position at an irradiation distance of 10 mm is 8,600W/cm2.
A 1.4-mm-diameter are can be irradiated at 70% of the center intensity (6020mW/cm2).
If an intensity of 500 mW/cm2 and irradiation area of 6 mm diameter are required, draw a line on the graph that covers the ±3 and 500 mW/cm2 positions. This determines the lens that will satisfy the area this line surrounds and the lens irradiation distance. In this case, we can see that the ANUJ6428 can maintain an intensity of 500 mW/cm2 or higher with an irradiation distance of 40 mm and area of 6 mm diameter.
|
|
|
|
|