AUTOMATION
CONTROLS

Search
Discontinued
Products



ADW1105HTW | DW Relays


DW Relays

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  
  • Download RoHS Compliance Certificate


Product Number ADW1105HTW
Part Number ADW1105HTW
Details Inrush type (16 A), Inrush current 100 A, IEC60335-1compliant type
Product name DW Relays
Features 1 Form A 8 A/16 A, Small, Polarized power relays (latching type)

*“ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market.


As of May 01, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number ADW1105HTW
Part Number ADW1105HTW
Protective construction Flux-resistant
Operating function 1 coil latching
Terminal shape PC board terminal
Contact rating type Inrush type (16A, Inrush current 100A)
Type classification IEC60335-1compliant type
Packing style Carton
Standard packing
Carton (pieces)
100
Standard packing
Case (pieces)
500

Coil data

Item Specifications
Rated coil voltage 5 V DC
Set voltage (at20°C) Max. 80% V of rated coil voltage (Initial)
Reset voltage (at20°C) Max. 80% V of rated coil voltage (Initial)
Rated operating current [±10%] (at 20°C) 40 mA
Coil resistance [±10%] (at 20°C) 125 Ω
Rated operating power 200 mW
Max. allowable voltage (at 20°C) 110% V of rated coil voltage

Specifications

Item Specifications
Contact arrangement 1 Form A
Contact shape Single
Contact resistance (initial) Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact material AgSnO2 type
Contact rating (resistive load) 16 A 277 V AC
Max. switching power (resistive load) 4,432 VA
Max. switching voltage 277 V AC
Max. switching current 16 A (AC)
Min. switching load (reference value) 100 mA 5 V DC
Insulation resistance (initial) Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric strength (initial) : Between open contacts 1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric strength (initial) : Between contact and coil 5,000 Vrms for 1 min (detection current: 10 mA)
Surge withstand voltage (initial) : Between contact and coil 12,000 V
Set time (Initial) (at 20°C) (Initial) Max. 15 ms at rated coil voltage (without bounce)
Reset time (Initial) (at20°C) Max. 15 ms at rated coil voltage (without bounce)
Shock resistance (Functional) 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Shock resistance (Destructive) 1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration resistance (Functional) 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
Vibration resistance (Destructive) 10 to 55 Hz (at double amplitude of 3 mm)
Mechanical life Min. 106 ope. (switching frequency: at 180 times/min)
Conditions Ambient temperature: -40 to +70°C (Over 8A to 16A)
Ambient temperature: -40 to +85°C (8A or less)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weight Approx. 8 g

Expected electrical life

Item Specifications
Resistive load Min. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min)
Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s)

Electrical life

Item Specifications
Inrush load; Tungsten Min. 25x103 ope.
Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s)

Return to top

Information on Compliance with Standards

Standard Name Status Information on Compliance
UL/C-UL

Approval

File No. E43149
Rating 16A 277V AC R 50,000cycles at60°C
16A 277V AC R 20,000cycles at85°C
8A 250V AC R 50,000cycles at85°C
5A 347V AC R 50,000cycles at85°C(UL only)
5A 30V DC R 50,000cycles at85°C
1200W Tungsten 240V AC 6,000cycles at50°C
600W Tungsten 120V AC 25,000cycles at50°C
1A 277V AC Electronic ballast 12,000cycles at40°C
2A 277V AC Electronic ballast 6,000cycles at40°C
5A 277V AC Standard ballast 6,000cycles at50°C
Remarks -
Last update December 4, 2018
CSA

N/A

File No. -
Rating -
Remarks CSA standard certified by C-UL
Last update December 4, 2018
VDE

Approval

File No. 40032254
Rating 16A 277V AC (cosφ=1.0) 50,000cycles at70°C
16A 277V AC (cosφ=1.0) 20,000cycles at85°C
8A 250V AC (cosφ=1.0) 50,000cycles at85°C
5A 30V DC (0ms) 50,000cycles at85°C
*1) 24A 277V AC (cosφ=1.0) 50cycles at85°C
*2) 16A 277V AC (cosφ=1.0) 10,000cycles at 85°C
Remarks *1) Test according to DIN EN 62368-1 (VDE 0868-1) / IEC62368-1 ; Clause G.2.2
*2) Test according to DIN EN 62368-1 (VDE 0868-1) / IEC62368-1 ; Clause G.2.1 : No temporary malfunction allowe
Last update August 9, 2022
TV

Approval

File No. E43149
Rating TV-8 (240V AC) 25,000cycles at40°C
Remarks -
Last update December 4, 2018
CQC

Approval

File No. CQC16002150890
Rating 16A 250V AC
Remarks -
Last update February 1, 2024
Mark on products* UL C-UL Recognaized VDE HOUSE MARK

* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.


Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)