Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > DZ-S Relays > Part Number > ADZS22112
*Photo may vary from actual product.
Product Number | ADZS22112 |
Part Number | ADZS22112 |
Product name | DZ-S Relays |
Features | IEC62055-31 UC3 compliant, 1 Form A 90 A, Power latching relays |
* | “ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market. |
---|
As of May 04, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | ADZS22112 |
Part Number | ADZS22112 |
Protective construction | Dust Cover |
Operating function | 2 coil latching |
Terminal shape | Vertical terminal |
Contact rating type | High switching capacity |
Standard packing Carton (pieces) |
20 |
Standard packing Case (pieces) |
200 |
Item | Specifications |
---|---|
Rated coil voltage | 12 V DC |
Set voltage (at20°C) | Max. 70% V of rated coil voltage (Initial) |
Reset voltage (at20°C) | Max. 70% V of rated coil voltage (Initial) |
Rated operating current [±10%] (at 20°C) | 250 mA |
Coil resistance [±10%] (at 20°C) | 48 Ω |
Rated operating power | 3.0 W |
Max. allowable voltage (at 20°C) | 130% V of rated coil voltage |
Item | Specifications |
---|---|
Contact arrangement | 1 Form A |
Contact shape | Single |
Contact voltage drop (Initial) | Max. 0.09 V (at 90 A), Max. 0.05 V (at 10 A) |
Contact material | AgSnO2 type |
Contact rating (resistive load) | 90 A 250 V AC |
Max. switching power (resistive load) | 24,840 VA |
Max. switching voltage | 276 V AC |
Max. switching current | 90 A (AC) |
Min. switching load (reference value) | 100 mA 125 V AC |
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric strength (initial) : Between open contacts | 2,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric strength (initial) : Between contact and coil | 4,000 Vrms for 1 min (detection current: 10 mA) |
Surge withstand voltage (initial) : Between contact and coil | 12,000 V |
Set time (Initial) (at 20°C) (Initial) | Max. 20 ms at rated coil voltage (without bounce) |
Reset time (Initial) (at20°C) | Max. 20 ms at rated coil voltage (without bounce) |
Shock resistance (Functional) | 300 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Shock resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 2 mm) |
Mechanical life | Min. 100x103 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +85°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 45 g |
Item | Specifications |
---|---|
Resistive load | [switching frequency: at 20 times/min (ON : OFF = 2 s : 4 s)] Min. 10x103 ope. 90 A 250 V AC |
Item | Specifications |
---|---|
UC3 Class (IEC62055-31) | [switching frequency ON : OFF = 10 s : 20 s] Min. 10x103 ope. 90 A 276 V AC (cosΦ = 1 : 5,000 cycles, cosΦ = 0.5 : 5,000 cycles) |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)