Product Number | AEWA1200 |
Part Number | AEWA1200 |
Details | Large pipe size |
Product name | Air Flow Monitor EWA1(Discontinued) |
Item | Specifications |
---|---|
Product Number | AEWA1200 |
Part Number | AEWA1200 |
Item | Specifications |
---|---|
Rated pressure range | 0 to 1 MPa (gauge pressure) |
Measurable fluid | Air (compressed air) |
Rated operating voltage | 24 V DC plus or minus 10 % |
Rated power consumption | 40 mA or less |
Pulse output(Pulse output 1 and Pulse output 2) | Open drain output -Max. inflow current: 10 mA -Applied voltage: 24 V DC or less -Residual voltage: 1 V or less (at inflow current 10 mA) |
Pulse output(Pulse output 1 and Pulse output 2):Output mode | Pulse output 1: Direct flow pulse Pulse output 2: Reverse flow pulse, Flow limit alarm (select by button operation) |
Pulse output(Pulse output 1 and Pulse output 2):Over current protection | Equipped |
Pulse output(Pulse output 1 and Pulse output 2):Pulse output duty | 1: 1 (35 to 65 %) |
Analog current output | Output current: 4 to 20 mA Output accuracy: plus or minus 0.1 mA Max. external load: 400 Ohm or less |
Analog current output:Output mode | Instant flow, air pressure and temperature (select by button operation) |
Analog current output:Output mode:Instant flow | Zero point: 4 mA (Direct flow display mode, reverse flow ~ within low flow cut off), 12 mA (Direct/Reverse flow display mode, within low flow cut off) |
Analog current output:Output mode:Air pressure | 0 kPa: 4 mA 1 MPa: 20 mA |
Analog current output:Output mode:Temperature | −10 degrees +14 degrees Fahrenheit: 4 mA +60 degrees +140 degrees Fahrenheit: 20 mA |
Pressure loss | Extremely small (same as straight pipe) |
Response time | 500 ms |
Enclosure protection | IP64 (IEC) |
Ambient temperature | −10 to +60 degrees +14 to +140 degrees Fahrenheit (Storage: −20 to +70 degrees −4 to +158 degrees Fahrenheit ) |
Ambient humidity | 90 % RH or less (No dew condensation or icing allowed) |
Item | Specifications |
---|---|
Pipe size | 200 A (8B) |
Flow range (actual flow) | −40 to −2,000 m3 / h or +40 to +2,000 m3 / h |
Flow measuring accuracy:±5 % R.S. | −40 to −200 m3 / h or +40 to +200 m3 / h |
Flow measuring accuracy:±2 % R.S. | −200 to −2,000 m3 / h or +200 to +2,000 m3 / h |
Normal conversion accuracy | plus or minus 2 % R.S. (at dry air, ordinary temperatures and 0.5 MPa) |
Unit for pulse output | 0.1, 1, 10 Nm3 / pulse or m3 / pulse |
Low flow cut off | Within plus or minus 9.0 m3 / h |
Material | Measuring pipe: Stainless steel alloy, PPS and phlor silicone rubber |
Net weight | 24.4 kg approx. |
Accessories | Positioning collar: 2 pcs M4 hexagon wrench: 1 pc |