Item Specifications
Product Number AKR2015
Part Number AKR2015

General specifications

Item Specifications
Rated voltage 12 to 24V DC
Operating voltage range 10.8 to 26.4V DC
Current consumption 200 mA or less (During sending)
Inrush current 23 A (when 24 V DC)
Ambient temperature -10 to +50 degrees
Storage temperature -20 to +70 degrees
Ambient humidity 30 to 85 %RH (at 25 degrees non-condensing)
Storage humidity 30 to 85 %RH (at 25 degrees non-condensing)
Breakdown voltage(initial) 500 V AC for 1 min. (Between power terminal and FG / DSUB connector, Between power terminal and input / output terminal, Between input terminal and output terminal)
Insulation resistance(initial) 100 M ohm or more (at 500 V DC)(Between power terminal and FG / DSUB connector, Between power terminal and input / output terminal, Between input terminal and output terminal)
Vibration resistance 10 to 55 Hz 1cycle / min. Double amplitude of 0.75 mm, 10 min. on 3 axes
Shock resistance 98 m / s2 or more, 4 times on 3 axes
Noise immunity 1000 V [p-p] with pulse width 50 ns, 1 micro s (based on in-house measurements)(Power terminal)
Overcurrent protection of power supply Fuse (Rated current: 3.15A)
Weight Approx. 160 g

Wireless specifications

Item Specifications
Wave type Direct sequence spread spectrum (DS-SS)
Transmission distance Approx. 250 m outdoors (straight, obstacle-free distance), Approx. 50 m indoors
(Note) The main unit, standard antenna and antenna with cable are designed for indoor use. If they are used outdoors, then take water-proof measures such as using plastic cases, etc.
Wave output 6 mW / MHz or less
Frequency 2403.328 MHz to 2480.128 MHz
Number of channels 76 ch (Select with communication channel switch)
(Note) Adding to the fixed channel, 76 ch (00 to 4B), 89 group channel can be selected. Group channel is the function that it selects connectable channel from several fixed channels automatically. When using repeater function, use with the fixed channel. When using group channel, settable channel numbers are decreased in the same communication area and the communication time becomes longer.
Number of channels in same transmission area 15 channels recommended (when select fixed channel)
(Note) It is different according to the mounting conditions, when several channels are used in the same communication area, communication error might occur due to interference radio wave.
Transmission speed 134kbps
Communication style 1: N topology (N: 99 units max.)
Repeater function 8 repeaters (Between master and slave)
Response time OFF to ON, ON to OFF: Max. 80 ms
(Note) There are no error without serial communication at 1: 1 topology. Response time: Time from input signal to input terminal to output from output terminal in connected equipment. When input signal is shorter than response time, there is a possibility not to transfer to output side.

Serial communication specifications

Item Specifications
Interface Conforming to RS232C
Transmission distance 15 m
Transmission speed 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bit / s (Selectable with MODE switch)
Communication method Half-duplex
Synchronous system Synchronous communication method
Transmission format Stop bit: 1 bit
Parity: Not available / Available (odd / even)
Data length: 7bit / 8bit
Data buffer 2,048 bytes (Max. data byte size for send and receive one time)

Input specifications

Item Specifications
Insulation method Optical coupler
Rated input voltage 12 to 24 V DC (voltage input)
Operating voltage range 10.8 to 26.4 V DC
Rated input current Approx. 3 mA / when 12 V, Approx. 6 mA / when 24 V
Points per common 8 points / common (Either positive or negative of input power supply can be connected.)
(Note) In case simultaneously ON of input and output, input number and output number are restricted according to the ambient temperature.
Input impedance Approx. 4 kohm
Operation indicator LED display (green)

Output specifications

Item Specifications
Insulation method Optical coupler
Output type Open collector (NPN)
Rated load voltage 12 to 24 V DC
Allowable load voltage range 10.8 to 26.4 V DC
Max. load current 0.3 A
Max. inrush current 1.5 A
Points per common 9 points / common (Signal output, Communication error output)
(Note) In case simultaneously ON of input and output, input number and output number are restricted according to the ambient temperature.
Off state leakage current 1 micro A or less
On state voltage drop 1.5 V DC or less
External power supply(+, – terminal):Voltage -
External power supply(+, – terminal):Current -
Surge absorber Zener diode
Operation indicator LED display

Functions specifications

Item Specifications
Setting function - Operating mode change (SET, RUN, TEST)
- Communication channel change (CH switch)
- Unit No. change (UNIT No. switch)
- Serial communication setup (MODE switch)
- Slave registration
- Initializing (Factory setting)
- Data holding (When communication error)
Test function Communication test: 3-stage LED display (With setting tool, it can do various communication tests such as changing data amount, including repeaters and so on. And it can measure an approximate communication time.)
Field intensity monitor: 3-stage LED display (With setting tool, it can display and record a field intensity of each channel by numeric value.)
LED display - Distinguish master or slave (MASTER)
- On communication, Power on (COM.)
- On setting, Complete setting (SET)
- Error, Alarm, Caution (ALARM)
- Level indication (1, 2, 3: when using test function)
- I / O operating display (16 or 12 points + 1 point of communication error)

Return to top

Accessories (Option) As of March 31, 2022

no_image
Product Number AFPG805
Part Number AFPG805
Product name Power cable

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)