[System Maintenance Notice]
Due to ongoing system maintenance, the site search and specification search functions are temporarily unavailable. We apologize for any inconvenience this may cause and appreciate your understanding.
Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > LQ Relays > Part Number > ALQ118S
*Photo may vary from actual product.
Product Number | ALQ118S |
Part Number | ALQ118S |
Product name | LQ Relays |
Features | Compliant with IEC/EN60335-1*1*2 /EN60079-15*3 1 Form A/1 Form C 10 A small power relays |
* | “ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market. |
---|
As of July 28, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | ALQ118S |
Part Number | ALQ118S |
Protective construction | Sealed |
Operating function | Single side stable |
Terminal shape | PC board terminal |
Relay shape | Slim type |
Contact rating type | Standard type |
Coil insulation class | Class B insulation |
Packing style | Tube package |
Standard packing Carton (pieces) |
50 |
Standard packing Case (pieces) |
1,000 |
Item | Specifications |
---|---|
Rated coil voltage | 18 V DC |
Operate voltage (at20°C) | Max. 75% V of rated coil voltage (Initial) |
Release voltage (at20°C) | Min. 5% V of rated coil voltage (Initial) |
Rated operating current [±10%] (at 20°C) | 22.2 mA |
Coil resistance [±10%] (at 20°C) | 810 Ω |
Rated operating power | 400 mW |
Max. allowable voltage | 110% V of rated coil voltage (at 85℃) 150% V of rated coil voltage (at 20℃) |
Item | Specifications |
---|---|
Contact arrangement | 1 Form C |
Contact shape | Single |
Contact resistance (initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) |
Contact material | AgNi type |
Contact rating (resistive load) | N.O.: 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC N.C.: 3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC |
Max. switching power (resistive load) | N.O.: 1,250 VA, 150 W N.C.: 500 VA, 30 W |
Max. switching voltage | 250 V AC, 30 V DC |
Max. switching current | N.O.: 10 A (125 V AC), 5 A (30 V DC) N.C.: 3 A (125 V AC), 1 A (30 V DC) |
Min. switching load (reference value) | 100 mA 5 V DC |
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric strength (initial) : Between open contacts | 750 Vrms for 1 min (detection current: 10 mA) |
Dielectric strength (initial) : Between contact and coil | 4,000 Vrms for 1 min (detection current: 10 mA) |
Surge withstand voltage (initial) : Between contact and coil | 8,000 V |
Operate time (initial) (at 20°C) | Max. 20 ms at rated coil voltage (without bounce) |
Release time (initial) (at 20°C) | Max. 20 ms at rated coil voltage (without bounce, with diode) |
Shock resistance (Functional) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Shock resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 μs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 2 mm) |
Mechanical life | Min. 10x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +85℃ (-40 to +60℃ at our standard packing condition) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 7 g |
Item | Specifications |
---|---|
Resistive load | [at 20℃, Switching frequency: ON:OFF=1.5 s:1.5 s with diode] Form A contact: Min. 100x103 ope. 5 A 30 V DC Form A contact: Min. 50x103 ope. 10 A 125 V AC Form A contact: Min. 50x103 ope. 5 A 250 V AC Form B contact: Min. 200x103 ope. 3 A 125 V AC Form B contact: Min. 200x103 ope. 2 A 250 V AC Form B contact: Min. 100x103 ope. 1 A 30 V DC |
Mark on products* |
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])