[System Maintenance Notice]
Due to ongoing system maintenance, the site search and specification search functions are temporarily unavailable. We apologize for any inconvenience this may cause and appreciate your understanding.

Search
Discontinued
Products


DP-M2A | Micro-differential Pressure High-precision Digital Pressure Sensor [For Gas] DP-M(Discontinued)


Micro-differential Pressure High-precision Digital Pressure Sensor [For Gas] DP-M(Discontinued)

*Photo may vary from actual product.



  • Discontinued
  • Last time buySeptember 30, 2019
Product Number DP-M2A
Part Number DP-M2A
Product Micro-differential Pressure High-precision Digital Pressure Sensor [For Gas]
Product name Micro-differential Pressure High-precision Digital Pressure Sensor [For Gas] DP-M(Discontinued)
  • Substitute -
  • Sub Prod No. -
  • Sub Part No. -
  • Remark Sorry, no suggested alternative products.

Spec Detail As of September 30, 2019

Item Specifications
Product Number DP-M2A
Part Number DP-M2A
CE marking directive compliance EMC Directive, RoHS Directive
Type of pressure Differential pressure
Rated pressure range 0 to 2.00 kPa.D {0 to 204 mmH2O.D}
Set pressure range 0 to 2.00 kPa.D {0 to 204 mmH2O.D}
Set pressure resolution 0.01 kPa.D {1 mmH2O.D}
Pressure withstandability 6 kPa.D {612 mmH2O.D}
Applicable fluid Non-corrosive gas
Selectable units kPa, mmH2O
Supply voltage 12 to 24 V DC +10/-15% Ripple P-P 10 % or less
Current consumption 75 mA or less
Comparative output NPN open-collector transistor
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less (between comparative output and 0 V)
・Residual voltage : 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
Comparative output:Utilization category DC-12 or DC-13
Comparative output : Output operation Selectable either normally open (NO) or normally closed (NC) by the key
Comparative output : Hysteresis 0.01 kPa.D {1 mmH2O.D}
Comparative output : Repeatability Within ±1 % F.S.
Comparative output : Response time 10 ms or less
Comparative output : Short-circuit protection Incorporated
Analog current output Output current : 4 to 20 mA (from 0 to 1.96 kPa.D {0 to 200 mmH2O.D})
Zero-point : within 4 mA ± 1 % F.S.
Span : within 16 mA ± 3 % F.S.
Linearity : within ±1 % F.S.
Load resistance : 0 to 250 Ω
Display 3 digit red LED display (Sampling rate : 4 times/sec. approx.)
Display : Displayable pressure range -0.05 to 2.10 kPa.D {-5 to 210 mmH2O.D}
Indicators : Operation Orange LED (lights up when the comparative output is ON)
Indicators : Pressure unit Red LED (The indicator corresponding to the selected unit lights up during the sensing mode.)
Indicators : M1 setting Red LED (blinks in the M1 setting mode)
Indicators : M2 setting Red LED (blinks in the M2 setting mode)
Pollution degree 3 (Industrial environment)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed),
Storage: -10 to +60 ℃ +14 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage : 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Temperature characteristics Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉
: within ±3 % F.S. of detected pressure at +25 ℃ +77 ℉
Pressure port ø4.6 mm ø0.181 in resin pipe
(Note): For production before April 2015 : ø4.8 mm ø0.189 in
Material Front case : ABS, Rear case : ABS, LED display : Acrylic, Pressure port : PA
Cable 0.18 mm2 4-core oil resistant cabtyre cable, 2 m 6.562 ft long
Cable extension Extension up to total 100 m 328.084 ft (less than 10 m 32.808 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Weight Net weight : 75 g approx., Gross weight : 135 g approx
Remark Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)