SF-C11 | Exclusive Control Unit for Safety Light Curtain SF-C10


Exclusive Control Unit for Safety Light Curtain SF-C10

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


Product Number SF-C11
Part Number SF-C11
Product Exclusive Control Unit for Safety Light Curtain
Details Connector connection type control unit
Product name Exclusive Control Unit for Safety Light Curtain SF-C10

As of April 19, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number SF-C11
Part Number SF-C11
Connectable safety light curtains SF4D / SF4B / SF4B-G / SF2B series
Applicable standards EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1:2015 (Category 4, , PLe), IEC 61496-1 (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Applicable regulations CE Marking (Machinery Directive, EMC Directive, RoHS Directive),UKCA Marking (Machinery Regulations, EMC Regulations, RoHS Regulations)
Power voltage 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption 100 mA or less (without safety light curtain)
Fuse rating Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Enabling path NO contact × 3 (13-14, 23-24, 33-34)
Enabling path : Utilization AC-15, DC-13 (IEC 60947-5-1)
Enabling path : Rated operation voltage (Ue) / Rated operation current (le) 30 V DC / 6 A, 230 V AC / 6 A, resistive load(For inductive load, during contact protection)Min. applicable load: 10 mA (at 24 V DC)
(Note) : If several SF-C11 or SF-C13 units are being used in a line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.
Enabling path : Contact material / contacts Silver tin oxide (AgSnO), self cleaning, positively driven
Enabling path : Contact resistance 100 mOhm or less (initial value)
Enabling path : Contact protection fuse rating 6 A (slow blow)
Enabling path : Mechanical lifetime 10,000,000 times or more (open/close frequency of 180 times/min)
(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
Enabling path : Electrical lifetime 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)
(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
Pick-up delay(Auto reset / Manual reset) 80 ms or less / 90 ms or less
Response time 10 ms or less
Auxiliary outputs Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path)
Auxiliary output:Rated operation voltage / current 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
Auxiliary output:Contact protection fuse rated 2 A (slow blow)
Semiconductor auxiliary output(AUX)
PNP open-collector transistor
• Maximum source current: 60 mA
• Applied voltage: same as supply
voltage (between the auxiliary output and +V)
• Residual voltage: 2.3 V or less (at 60 mA source current)
• Leakage current: 2 mA or less

NPN open-collector transistor
• Maximum sink current: 60 mA
• Applied voltage: same as supply voltage (between the auxiliary output and 0V)
• Residual voltage: 1.5 V or less (at 60 mA sink current)
• Leakage current: 2 mA or less
Semiconductor auxiliary output(AUX):Output operation Related to auxiliary output of safety light curtain
Excess voltage category II
Indicators:Power supply (Ui) Green LED (lights up when the power is ON)
Indicators : Enabling path (OUT) Green LED (lights up when the enabling contacts are closed)
Indicators:Interlock (INTER_LOCK) Yellow LED (lights up when safety output is opened)
Indicators:Fault (FAULT) Yellow LED (blinks when fault occurs)
External relay monitor function Incorporated
Trailing edge function Incorporated
Polarity selection function Incorporated (Sliding switch allows selection of plus/minus ground)
Minus ground: Correspond to PNP output safety light curtain
Plus ground: Correspond to NPN output safety light curtain
(Note):Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.
Pollution degree 2
Environmental resistance:Degree of protection Enclosure: IP40
Terminal: IP20
Environmental resistance:Ambient temperature -10 to +55 ℃ +14 to +131
(No dew condensation or icing allowed),
Storage: -25 to +70 ℃ -13 to +158℉
Environmental resistance:Ambient humidity 30 to 85 % RH, Storage: 30 to 95 % RH
Environmental resistance:Vibration resistance Malfunction resistance 10 to 55Hz, 0.35 mm 0.014 in double amplitude 20 times each in X, Y, and Z directions
Enclosure material ABS
Connection terminal Detachable spring-cage terminal
Weight Net weight: 320 g approx.

Return to top

Accessories (Option)

Extension Cable
Product Number SFB-CCJ10D
Part Number SFB-CCJ10D
Product Standard components (8-core cable) Extension cable
Details With connectors on both ends For receiver
Product name Extension Cable
Extension Cable
Product Number SFB-CCJ10E
Part Number SFB-CCJ10E
Product Standard components (8-core cable) Extension cable
Details With connectors on both ends For emitter
Product name Extension Cable
Extension Cable
Product Number SFB-CCJ3D
Part Number SFB-CCJ3D
Product Standard components (8-core cable) Extension cable
Details With connectors on both ends For receiver
Product name Extension Cable


More



Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)