SF-CL1T264T | CC-Link Safety System Remote I/O Unit for Light Curtain SF-CL1T264T(Discontinued)


CC-Link Safety System Remote I/O Unit for Light Curtain SF-CL1T264T(Discontinued)

*Photo may vary from actual product.



  • Discontinued
  • Last time buyFebruary 29, 2016
Product Number SF-CL1T264T
Part Number SF-CL1T264T
Product CC-Link Safety System Remote I/O Unit for Light Curtain
Product name CC-Link Safety System Remote I/O Unit for Light Curtain SF-CL1T264T(Discontinued)
  • Substitute -
  • Sub Prod No. -
  • Sub Part No. -
  • Remark Sorry, no suggested alternative products.

Spec Detail As of February 29, 2016

Item Specifications
Product Number SF-CL1T264T
Part Number SF-CL1T264T
Connectable safety light curtains SF4B series
Applicable standards IEC 61508 SIL 3
Unit power:Supply voltage 24 V DC plus or minus 10 % Ripple P-P 10 % or less
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
Unit power:Current consumption 140 mA or less (24 V DC, with all points ON)
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
Unit power:Protective function Unit power overvoltage / overcurrent protection function
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
Unit power:Fuse 0.8 A (Not replaceable)
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
Unit power:Momentary power failure period 10ms or less
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
Input specifications:No. of input points Input of light curtain: 2 points (with interference prevention function)
Input of terminal block: 6 points (input terminals: 12 points)
(Note) Total number of input points is 8 points, and use 2 points for control output (OSSD 1, 2) of 2 light cutains. Two inputs terminals are assigned for each input since dual wiring is supported.
Input specifications:Insulation method Photocoupler
Input specifications:Rated input voltage 24 V DC
Input specifications:Rated input current 4.6 mA approx.
Input specifications:Operating voltage range 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Input specifications:Max. simultaneous input points 100%
Input specifications:ON voltage / ON current 15 V DC or more / 2 mA or more
Input specifications:OFF voltage / OFF current 5 V DC or less / 0.5 mA or less
Input specifications:Input resistance 5.6 kOhm approx.
Input specifications:Input type Negative common
Input specifications:Response time OFF to ON: 0.4 ms or less (at 24 V DC, excluding connecting device)
ON to OFF: 0.4 ms or less (at 24 V DC, excluding connecting device)
Input specifications:Safety remote station input response time 32 ms or less + filter-out time (1 ms, 5 ms, 10 ms, 20 ms, 50 ms)
dummy 4 points (source + sink type)
2 points (source + source type)
dummy Photocoupler
dummy 24 V DC
dummy 24 V DC plus or minus 10 % Ripple P-P 10 % or less
dummy 0.5 A / point
dummy 1.0 A (10 ms or less)
dummy 0.5 mA or less
dummy 1.0 V DC or less
dummy Output short-circuit protection function
dummy Source + sink type, Source + source type
dummy OFF to ON: 0.4 ms or less (at 24 V DC)
ON to OFF: 0.4 ms or less (at 24 V DC)
dummy 32 ms or less
dummy Incorporated (Zener diode)
dummy 24 V DC plus or minus 10 % Ripple P-P 10 % or less
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
dummy 60 mA (24 V DC, with all points ON, excluding external load current)
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
dummy External power supply overvoltage / overcurrent protection function
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
dummy 8 A (Not replaceable)
(Note) The power supply connected to this product must satisfy the following conditions
1 SELV (Safety Extra Low Voltage): Reinforced insulated from hazardous potential part (48 V or more)
2 Compliance with the LVD (Low Voltage Directive)
3 Output voltage within 21.6 V to 26.4 V DC (Ripple P-P: 10 % or less.)
dummy 16 input points / common, 4 output points / common (Terminal block 2-wire type)
dummy Max. 4 A (Total of inputs and outputs)
dummy 1 station
dummy 10 12 times
dummy 38 ms
Environmental resistance:Ambient temperature 0 to +55 degrees +32 to +131 degrees Fahrenheit (No dew condensation), Storage: -40 to +75 degrees -40 to +167 degrees Fahrenheit
Environmental resistance:Ambient humidity 5 to 95 % RH, Storage: 5 to 95 % RH
Environmental resistance:Voltage withstandability 500V AC between all external DC terminals and ground, for 1 minute
Environmental resistance:Insulation resistance 10 MOhm or more between all external DC terminals and ground, by a 500 V DC insulation resistance tester
Environmental resistance:Vibration resistance Conforming to JIS B 3502, IEC 61131-2
Environmental resistance:Shock resistance Conforming to JIS B 3502, IEC 61131-2
Overvoltage category II
Pollution degree 2
Wiring cable 0.3 to 2.0 mm2
dummy RAV1.25-3 (Conforming to JIS B 2805) (Applicalbe wire size: 0.3 to 1.25 mm2)
Weight Net weight: 0.7 kg approx.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)