RT-3 UNIT RELAY (PhotoMOS Power type) /4-POINT TERMINAL (Without relay type)

Rating

 

■ Input ratings (per relay)

Part No. Rated input voltage Operate voltage
(at 25°C)
Release voltage
(at 25°C)
Input current
during application of
rated input voltage
(at 25°C)
Allowable variation of
rated input voltage
(at -20 to +55°C)
AY34001 12 V DC Max. 9.5 V DC
(5.1 V typ.)
Min. 3.0 V DC
(5.0 V typ.)
6.2 mA typ. 90 to 110% V of
rated input voltage
AY35001
AY34002 24 V DC Max. 15.0 V DC
(6.8 V typ.)
Min. 3.5 V DC
(6.5 V typ.)
6.7 mA typ.
AY35002
*This product has a built-in input current limiting resistor; therefore, it is not necessary to externally connect a resistor to the input. The input voltage can be applied directly.

 

■ Output rating (per relay, at 25°C)

Part No. Equipped relay Max. load voltage Recommended voltage Continuous load current Peak load currant
AY34001 AQZ102
(DC only)
60 V (DC) 0 to 30 V (DC) 2 A (DC) 9 A
(100 ms 1 shot)
AY34002
AY35001 AQZ204
(AC/DC dual use)
400 V
(DC, AC peak value)
0 to 200 V (DC)
0 to 125 V (AC)
0.3 A
(DC, AC peak value)
1.5 A
(100 ms 1 shot)
AY35002
*1During 4-point simultaneous operation, the rating per point is also as shown in the table above.
*2The load current varies depending on ambient temperature. Refer to the “REFERENCE DATA Load current vs. ambient temperature characteristics”.

Return to top

Specifications

Item Specifications Condition
Dielectric
strength (initial)
Between
input and output
2,000 V AC for 1 min
Between
different terminals (between relays,
both ways)
1,500 V AC for 1 min
Insulation resistance Min. 100 MΩ
(Measured portion is the same as the case of dielectric strength.)
Using 500 V DC megger
Shock resistance Destructive
shock resistance
Min. 196 m/s2 In vertical, horizontal and longitudinal directions
Destructive
vibration resistance
10 to 55 Hz at double amplitude of 1 mm In vertical, horizontal and longitudinal directions
Use condition Ambient temperature -20 to +55°C Avoid icing and condensation
Ambient humidity 35 to 85% RH Avoid condensation
Storage temperature -30 to +80°C Avoid icing and condensation
Terminal screw fasten torque 0.3 to 0.5 N·m (3 to 5 kgf·cm)  
Cross connection protecting diode 1 A, inverse voltage 400 V  
Unit weight Approx. 100 g  
*1Dielectric strength and insulation resistance are initial values.
*2Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere.
This may cause some troubles like insulation failure of the socket or the PC board. Take care under this condition.
*3Below 0°C, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition.

Return to top

Reference data

1.Load current vs. ambient temperature characteristics

Allowable ambient temperature: –20°C to +55°C

Load current vs. ambient temperature characteristics

2.Load current vs. ambient temperature characteristics

Allowable ambient temperature: –20°C to +55°C

Load current vs. ambient temperature characteristics

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



Related Information
Service & Support

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)