[System Maintenance Notice]
Due to ongoing system maintenance, the site search and specification search functions are temporarily unavailable. We apologize for any inconvenience this may cause and appreciate your understanding.
Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Signal Relays (2A or less) > Signal Relays (2A or less) Lineup > DS Relays > Rating/Performance
|
Type | Rated coil voltage | Operate voltage* (at 20°C) |
Release voltage* (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power | Max. allowable voltage (at 50°C) |
---|---|---|---|---|---|---|---|
Standard type (M) |
1.5 V DC | Max. 70% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 266.7 mA | 5.63 Ω | 400 mW | 120% V of rated coil voltage |
3 V DC | 133.3 mA | 22.5 Ω | |||||
5 V DC | 80 mA | 62.5 Ω | |||||
6 V DC | 66.7 mA | 90 Ω | |||||
9 V DC | 44.4 mA | 203 Ω | |||||
12 V DC | 33.3 mA | 360 Ω | |||||
24 V DC | 16.7 mA | 1,440 Ω | |||||
48 V DC | 8.3 mA | 5,760 Ω | |||||
High sensitivity type (S) |
1.5 V DC | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 133.3 mA | 11.3 Ω | 200 mW | 160% V of rated coil voltage |
3 V DC | 66.7 mA | 45 Ω | |||||
5 V DC | 40 mA | 125 Ω | |||||
6 V DC | 33.3 mA | 180 Ω | |||||
9 V DC | 22.2 mA | 405 Ω | |||||
12 V DC | 16.7 mA | 720 Ω | |||||
24 V DC | 8.3 mA | 2,880 Ω | |||||
48 V DC | 4.2 mA | 11,520 Ω |
* | square, pulse drive (JIS C 5442) |
---|
Type | Rated coil voltage | Set voltage* (at 20°C) |
Reset voltage* (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power | Max. allowable voltage (at 50°C) | |||
---|---|---|---|---|---|---|---|---|---|---|
Set coil | Reset coil | Set coil | Reset coil | Set coil | Reset coil | |||||
Standard type (M) | 1.5 V DC | Max. 70% V of rated coil voltage (Initial) | Max. 70% V of rated coil voltage (Initial) | 240 mA | 240 mA | 6.25 Ω | 6.25 Ω | 360 mW | 360 mW | 120% V of rated coil voltage |
3 V DC | 120 mA | 120 mA | 25 Ω | 25 Ω | ||||||
5 V DC | 72 mA | 72 mA | 69.4 Ω | 69.4 Ω | ||||||
6 V DC | 60 mA | 60 mA | 100 Ω | 100 Ω | ||||||
9 V DC | 40 mA | 40 mA | 225 Ω | 225 Ω | ||||||
12 V DC | 30 mA | 30 mA | 400 Ω | 400 Ω | ||||||
24 V DC | 15 mA | 15 mA | 1,600 Ω | 1,600 Ω | ||||||
48 V DC | 7.5 mA | 7.5 mA | 6,400 Ω | 6,400 Ω | ||||||
High sensitivity type (S) | 1.5 V DC | Max. 80% V of rated coil voltage (Initial) | Max. 80% V of rated coil voltage (Initial) | 120 mA | 120 mA | 12.5 Ω | 12.5 Ω | 180 mW | 180 mW | 160% V of rated coil voltage |
3 V DC | 60 mA | 60 mA | 50 Ω | 50 Ω | ||||||
5 V DC | 36 mA | 36 mA | 139 Ω | 139 Ω | ||||||
6 V DC | 30 mA | 30 mA | 200 Ω | 200 Ω | ||||||
9 V DC | 20 mA | 20 mA | 450 Ω | 450 Ω | ||||||
12 V DC | 15 mA | 15 mA | 800 Ω | 800 Ω | ||||||
24 V DC | 7.5 mA | 7.5 mA | 3,200 Ω | 3,200 Ω | ||||||
48 V DC | 3.75 mA | 3.75 mA | 12,800 Ω | 12,800 Ω |
* | square, pulse drive (JIS C 5442) |
---|
Item | Specifications | |
---|---|---|
Contact data | Contact arrangement | 1 Form C |
Contact resistance (initial) | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | |
Contact material | Ag+Au clad | |
Contact rating (resistive) | 2 A 30 V DC | |
Max. switching power (resistive) | 60 W, 125 VA | |
Max. switching voltage | 220 V DC, 250 V AC | |
Max. switching current | 3 A | |
Min. switching load (reference value)*1 |
10 μA 10 mV DC | |
Insulation resistance (initial) | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
|
Dielectric strength (initial) | Between open contacts | Standard type (M): 1,000 Vrms for 1 min (detection current: 10 mA) High sensitivity type (S): 500 Vrms for 1 min (detection current: 10 mA) |
Between contact and coil | Standard type (M): 1,500 Vrms for 1 min (detection current: 10 mA) High sensitivity type (S): 1,000 Vrms for 1 min (detection current: 10 mA) |
|
Time characteristics (initial) | Operate [Set] time | Max. 10 ms at rated coil voltage (at 20°C, without bounce) [Max. 10 ms (at 20°C, without bounce)] |
Release [Reset] time | Max. 5 ms at rated coil voltage (at 20°C, without bounce, without diode) [Max. 10 ms (at 20°C, without bounce)] |
|
Shock resistance | Functional | 490 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Destructive | 980 m/s2 (half-sine shock pulse: 6 ms) | |
Vibration resistance | Functional | 10 to 55 Hz (at double amplitude of: 3.3 mm, detection time: 10 μs) |
Destructive | 10 to 55 Hz (at double amplitude of: 5 mm) | |
Expected life | Mechanical life | Single side stable: Min. 100 x 106 ope. Latching: Min. 10 x 106 ope. (at 600 times/min) |
Conditions | Conditions for usage, transport and storage*2 | Ambient temperature: –40 to +70°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 3 g |
*1 | This value is a rough indication of the lower limit at which switching is possible at micro load level. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load analog circuit (10 V DC, 10 mA max. level). |
---|---|
*2 | For ambient temperature, please refer to the “GUIDELINES FOR RELAY USAGE” |
Conditions: Resistive load, at 60 times/min
Type | Switching capacity | Number of operations |
---|---|---|
1 Form C | 2 A 30 V DC | Min. 500 x 103 |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)