Type | Rated coil voltage | Operate voltage (at 20℃) |
Release voltage (at 20℃) |
Rated operating current (±10%, at 20℃) |
Coil resistance (±10%, at 20℃) |
Rated operating power | Max. allowable voltage (at 70℃) |
---|---|---|---|---|---|---|---|
150 mW | 1.5 V DC | Max. 75% V of rated coil voltage (Initial) |
Min. 10% V of rated coil voltage (Initial) |
100 mA | 15 Ω | 150 mW | 140% V of rated coil voltage |
3 V DC | 50 mA | 60 Ω | |||||
4.5 V DC | 33.3 mA | 135 Ω | |||||
5 V DC | 30 mA | 166 Ω | |||||
6 V DC | 25 mA | 240 Ω | |||||
9 V DC | 16.7 mA | 540 Ω | |||||
12 V DC | 12.5 mA | 960 Ω | |||||
24 V DC | 6.25 mA | 3,840 Ω | |||||
200 mW | 1.5 V DC | Max. 75% V of rated coil voltage (Initial) |
Min. 10% V of rated coil voltage (Initial) |
133.3 mA | 11.25 Ω | 200 mW | 120% V of rated coil voltage |
3 V DC | 66.7 mA | 45 Ω | |||||
4.5 V DC | 44.5 mA | 101.2 Ω | |||||
5 V DC | 40 mA | 125 Ω | |||||
6 V DC | 33.3 mA | 180 Ω | |||||
9 V DC | 22.2 mA | 405 Ω | |||||
12 V DC | 16.7 mA | 720 Ω | |||||
24 V DC | 8.3 mA | 2,880 Ω |
Item | Specifications | ||
---|---|---|---|
Contact data | Contact arrangement | 1 Form C | |
Contact resistance (initial) |
Max. 100 mΩ (by voltage drop 6 V DC 1 A) | ||
Contact material | Ag+Au clad | ||
Contact rating (resistive) |
1 A 30 V DC | ||
Max. switching power (resistive) |
30 W (DC) | ||
Max. switching voltage | 60 V DC | ||
Max. carrying current | 2 A | ||
Max. switching current (resistive load) |
1 A 30 V DC | ||
Min. switching load (reference value)*1 |
1 mA 1 V DC | ||
Insulation resistance (initial) |
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | ||
Electrical characteristics |
Dielectric strength (initial) |
Between open contacts |
500 Vrms for 1 min (detection current: 10 mA) |
Between contact and coil | 1,000 Vrms for 1 min (detection current: 10 mA) | ||
Operate time (at 20℃) | Max. 5 ms (at rated coil voltage, without bounce) | ||
Release time (at 20℃) | Max. 4 ms (at rated coil voltage, without bounce, without diode) | ||
Mechanical characteristics | Shock resistance |
Functional | 98 m/s2 [10G] (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Destructive | 980 m/s2 [100G] (half-sine shock pulse: 6 ms) | ||
Vibration resistance |
Functional | 10 to 55 Hz (at double amplitude of: 1 mm, detection time: 10 μs) | |
Destructive | 10 to 55 Hz (at double amplitude of: 2 mm) | ||
Expected life | Mechanical life | Min. 10 × 106 (Switching frequency: 180 times/min) | |
Electrical life | Min. 100 × 103 (1 A 30 V DC resistive) (at 20 cpm) | ||
Conditions | Conditions for usage, transport and storage *2 |
Ambient temperature: –40 to +70℃, Humidity: 5 to 85% RH (Avoid icing and condensation) |
|
Max. operating speed | 20 cpm at rated load | ||
Unit weight | Approx. 1.8 g |
*1 | This value is a rough indication of the lower limit at which switching is possible at micro load level. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. |
---|---|
*2 | The ambient temperature upper limit is the highest temperature that can satisfy the coil temperature rise value. Please refer to “Regarding ambient temperature” in the“GUIDELINES FOR RELAY USAGE”. |
|