SC

Specifications

Sensor units

Type Main unit Separate unit
Model No. SC-MIL SC-MIL-S
CE marking directive compliance EMC Directive, RoHS Directive -
Supply voltage 12 to 24 V DC ±10 % (Note 2) Depends on the supply voltage from SC-MIL
Allowable through current
(Note 3)
2 A or less
(Same as maximum permissible current consumption of all units connected to SC-MIL.)
1 A or less
(Same as maximum permissible current consumption of all units connected to SC-MIL-S.)
Signal channel No. Connectable up to 16 channels
(The signal from up to 16th point (counting from unit adjacent
to SC-MIL) of all units connected to SC-MIL is transferred.
However, the signal thereafter is not transferred. Note that
SC-MIL and SC-MIL-S do not occupy any signal point.)
Max. distance between units 10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together)
Ambient temperature –10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed),
Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Material Enclosure: Heat-resistant ABS
Net weight 25 g approx. 20 g approx.
Accessory Connector protection seal: 1 pc.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) The plug-in sensor main unit SC-MIL incorporates a cable lead-out connector in addition to the MIL connector, which allows to receive the supply voltage from the separate power supply.
3) When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value.
3) When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value.

Connector input extension units

Type Connector input extension units
For NPN output
devices
For PNP output
devices
1 channel 1 channel
Model No. SC-T1J SC-T1J-P
CE marking directive compliance EMC Directive, RoHS Directive
Supply voltage 12 to 24 V DC ±10 %
Current consumption
(Note 2)
20 mA or less (when all indicators light up)
Signal channel No. 1 input
Connectable device NPN open-collector, or
DC 2-wire output type
sensor, or switch etc.
PNP open-collector, or
DC 2-wire output type
sensor, or switch etc.
Supply current for
units (Note 3)
100 mA or less
Power indicator Green LED (Lights up when the power is ON)
Input indicator Green LED (Lights up when each channel input is ON)
Ambient temperature –10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed),
Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Material Enclosure: Heat-resistant ABS
Net weight 10 g approx.
Accessory SL-CP1 (Snap male connector): 1 pc.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) The current consumption and input current of the input unit connected are not included.
3) Set the maximum current passing through input / output line to 50 mA or less.

e-CON connector input extension unit

Type e-CON 1-channel connector input extension unit
Model No. SC-E1
Supply voltage 12 to 24 V DC ±10 %
Current consumption 20 mA or less (with all indicators on) (Note 1)
Input Connectable devices: NPN open-collector transistor output type
(Input 1) and DC 2-wire output type (Input 2) sensors (Note 2),
switches, and other devices
Current supply for input device: 100 mA or less
Input impedance: Approx. 17 kΩ (Input 1) or approx. 3.2 kΩ (Input 2)
Output NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (with sink current of 50 mA)
Power indicator Green LED (lights up when the power is ON)
Input indicator Green LED (lights up when input is being received by unit)
Ambient temperature –10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Material Enclosure: Flame-resistant PBT,
Connector: Polyester
Weight Net weight: 15 g approx.,
Gross weight: 40 g approx.
Accessory Connector (e-CON): 1

Notes:1) Does not include current consumption or input current for connected input devices.
2) Conditions of connectable DC 2-wire type input device
• Leak current: 1 mA or less (when the power is OFF),
Offset voltage: 3 V or less (when the power is ON)
• Product whose load current range includes 5 to 8 mA

e-CON connector input extension unit

Type e-CON 1-channel connector input extension unit
Model No. SC-E81
Supply voltage 12 to 24 V DC ±10 %
Current consumption 20 mA or less (with all indicators on) (Note 1)
Number of signals 8 inputs (Note 2)
Input Connectable devices: NPN open-collector transistor
output type sensors, switches, and other devices
Current supply for input devices: 800 mA or less
(total for 8 inputs) Input impedance: 17 kΩ approx.
Output NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (with sink current of 50 mA)
Power indicator Green LED (lights up when the power is ON)
Input indicator 8 green LEDs
(light up when input is received from the corresponding channel)
Ambient temperature –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 9 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Material Enclosure: Polycarbonate, Connector: Polyester
Weight Net weight: 40 g approx., Gross weight: 85 g approx.

Notes: 1) Does not include current consumption or input current for connected input devices.
2) Uses eight channels of signaling, regardless of the number of connected input devices.

Designation e-CON 8-channel connector input extension unit
(without an input signal indicator)
Model No. SC-E82
Supply voltage 5 to 24 V DC ±10 %
Current consumption 7 mA or less
Number of signals 8 inputs (Note 1)
Input Connectable devices: NPN/PNP open-collector transistor output
type sensors, switches, etc. and commercially available devices
and output devices including a DC 2-wire type sensor (Note 2)
Current supply for input devices: 800 mA or less (total for 8 inputs)
Power indicator Green LED (Lights up when the power is ON)
Ambient temperature -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: -10 to +50 ℃ +14 to +122 ℉,
if 8 to 9 units are connected in cascade: -10 to +45 ℃ +14 to +113 ℉)
Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Material Enclosure: Polycarbonate, Connector: Polyester
Weight Net weight: 40 g approx., Gross weight: 85 g approx.

Notes:

1) Uses eight channels of signaling, regardless of the number of connected input devices.
1) When using in combination with the SC-GU3 series, it cannot use as a commercially available device including a DC 2-wire type sensor or output.

Non-line connector

Type Non-line connector
Model No. CN-70
Applicable unit Refer to the list of "Applicable unit of non-line connector"
Supply voltage Depends on the supply voltage from SC-MIL
Supply current for units 100 mA or less
Signal channel No. 1 channel
Ambient temperature –10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed)
Storage: –20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Material Enclosure: ABS
Weight Net weight: 4 g approx.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) The non-line connector now can be used with 4-pin types, such as the FX-305 and LS-401, since its production run starting in August 2004.

Applicable unit of non-line connector

Designation Model No. Description
1-channel input
extension units
SC-T1J For NPN output devices
SC-T1J-P For PNP output devices
Digital fiber sensors
(Note)
FX-501/502 For NPN output devices
FX-501P/502P For PNP output devices
FX-551 For NPN output devices
FX-551P For PNP output devices
FX-301(B/G/H)
FX-301-HS
For NPN output devices
FX-301(B/G/H)P
FX-301P-HS
For PNP output devices
FX-305 For NPN output devices
FX-305P For PNP output devices
FX-411(B/G)
FX-412(B/G)
For NPN output devices
FX-411(B/G)P For PNP output devices
Manually set
fiber sensors
FX-311(B/G) For NPN output devices
FX-311(B/G)P For PNP output devices
Digital fiber sensors for
leak detection fiber / liquid
detection fiber
FX-301-F For NPN output devices
FX-301P-F For PNP output devices
Digital laser sensors
(Note)
LS-501 For NPN output devices
LS-501P For PNP output devices
LS-401/403 For NPN output devices
LS-401P For PNP output devices
Digital pressure sensor DPS-401/402 For NPN output devices
Compact inductive
proximity sensor
GA-311 For NPN output devices
Bank selection unit FX-CH For NPN input devices
FX-CH-P For PNP input devices

Notes: The 2-output type can output the output 1 (OUT 1) only from SC-MIL.
There is no connection for output 2 (OUT2).

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)