Cylindrical Inductive Proximity Sensor GX-U/GX-FU/GX-N (Discontinued Products)

Sensing characteristics

*TYPICAL

GX-5SU GX-5SUB

Sensing field

GX-5SU GX-5SUB Sensing field

Correlation between sensing object size and sensing range

GX-5SU GX-5SUB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 6 × 6 × t 1 mm 0.236 × 0.236 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-8MU GX-8MUB

Sensing field

Correlation between sensing object size and sensing range

GX-8MU GX-8MUB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-12MU(B) GX-F12MU-J

Sensing field

GX-12MU(B) GX-F12MU-J Sensing field

Correlation between sensing object size and sensing range

GX-12MU(B) GX-F12MU-J Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-18MU(B) GX-F18MU-J

Sensing field

GX-18MU(B) GX-F18MU-J Sensing field

Correlation between sensing object size and sensing range

GX-18MU(B) GX-F18MU-J Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-30MU(B) GX-F30MU-J

Sensing field

GX-30MU(B) GX-F30MU-J Sensing field

Correlation between sensing object size and sensing range

GX-30MU(B) GX-F30MU-J Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-8MLU GX-8MLUB

Sensing field

GX-8MLU GX-8MLUB Sensing field

Correlation between sensing object size and sensing range

GX-8MLU GX-8MLUB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-12MLU GX-12MLUB

Sensing field

GX-12MLU GX-12MLUB Sensing field

Correlation between sensing object size and sensing range

GX-12MLU GX-12MLUB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-18MLU GX-18MLUB

Sensing field

GX-18MLU GX-18MLUB Sensing field

Correlation between sensing object size and sensing range

GX-18MLU GX-18MLUB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-30MLU GX-30MLUB

Sensing field

GX-30MLU GX-30MLUB Sensing field

Correlation between sensing object size and sensing range

GX-30MLU GX-30MLUB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-N12M GX-N12MB

Sensing field

GX-N12M GX-N12MB Sensing field

Correlation between sensing object size and sensing range

GX-N12M GX-N12MB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-N18M GX-N18MB

Sensing field

Correlation between sensing object size and sensing range

GX-N18M GX-N18MB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-N30M GX-N30MB

Sensing field

GX-N30M GX-N30MB Sensing field

Correlation between sensing object size and sensing range

GX-N30M GX-N30MB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-N12ML GX-N12MLB

Sensing field

GX-N12ML GX-N12MLB Sensing field

Correlation between sensing object size and sensing range

GX-N12ML GX-N12MLB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 30 × 30 × t 1mm 1.181 × 1.181 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-N18ML GX-N18MLB

Sensing field

GX-N18ML GX-N18MLB Sensing field

Correlation between sensing object size and sensing range

GX-N18ML GX-N18MLB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in), the sensing range shortens as shown in the left figure.

GX-N30ML GX-N30MLB

Sensing field

GX-N30ML GX-N30MLB Sensing field

Correlation between sensing object size and sensing range

GX-N30ML GX-N30MLB Correlation between sensing object size and sensing range

As the sensing object size becomes smaller than the standard size (iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in), the sensing range shortens as shown in the left figure.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)