Compact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D

Specifications

Safety light curtain individual specifications

SF4D-F□(-01)(Finger protection type)

Type Min. sensing object ø14 mm ø0.551 in
(10 mm 0.394 in beam pitch)
Model No. SF4D-F15(-01) SF4D-F23(-01) SF4D-F31(-01) SF4D-F39(-01)
Number of
beam channels
15 23 31 39
Protective height
(Note 2)
150 mm
5.906 in
230 mm
9.055 in
310 mm
12.205 in
390 mm
15.354 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
140 mm
5.512 in
220 mm
8.661 in
300 mm
11.811 in
380 mm
14.961 in
Current consumption Emitter:110 mA or less
Receiver:130 mA or less
Emitter:120 mA or less
Receiver:130 mA or less
Emitter:120 mA or less
Receiver:140 mA or less
PFHD 1.21×10-9 1.48×10-9 1.80×10-9 2.07×10-9
MTTFD 1,031 years or more 833 years or more 672 years or more 582 years or more
Net weight
(Total of
emitter and receiver)
270g approx. 470g approx. 680g approx. 890g approx.
Type Min. sensing object ø14 mm ø0.551 in
(10 mm 0.394 in beam pitch)
Model No. SF4D-F47(-01) SF4D-F55(-01) SF4D-F63(-01) SF4D-F71(-01)
Number of
beam channels
47 55 63 71
Protective height
(Note 2)
470 mm
18.504 in
550 mm
21.654 in
630 mm
24.803 in
710 mm
27.953 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
460 mm
18.110 in
540 mm
21.260 in
620 mm
24.409 in
700 mm
27.559 in
Current consumption Emitter:120 mA or less
Receiver:140 mA or less
Emitter:120 mA or less
Receiver:150 mA or less
PFHD 2.40×10-9 2.66×10-9 2.99×10-9 3.25×10-9
MTTFD 498 years or more 447 years or more 396 years or more 363 years or more
Net weight
(Total of
emitter and receiver)
1,100g approx. 1,300g approx. 1,500g approx. 1,700g approx.
Type Min. sensing object ø14 mm ø0.551 in
(10 mm 0.394 in beam pitch)
Model No. SF4D-F79(-01) SF4D-F95(-01) SF4D-F111(-01) SF4D-F127(-01)
Number of
beam channels
79 95 111 127
Protective height
(Note 2)
790 mm
31.102 in
950 mm
37.402 in
1,110 mm
43.701 in
1,270 mm
50.000 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
780 mm
30.709 in
940 mm
37.008 in
1,100 mm
43.307 in
1,260 mm
49.606 in
Current consumption Emitter:120 mA or less
Receiver:150 mA or less
Emitter:120 mA or less
Receiver:160 mA or less
Emitter:120 mA or less
Receiver:170 mA or less
Emitter:120 mA or less
Receiver:180 mA or less
PFHD 3.58×10-9 4.17×10-9 4.76×10-9 5.36×10-9
MTTFD 328 years or more 281 years or more 245 years or more 217 years or more
Net weight
(Total of
emitter and receiver)
1,900g approx. 2,300g approx. 2,800g approx. 3,200g approx.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years).
2) When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.

SF4D-H□(-01)(Hand protection type)

Type Min. sensing object ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Model No. SF4D-H8(-01) SF4D-H12(-01) SF4D-H16(-01) SF4D-H20(-01)
Number of
beam channels
8 12 16 20
Protective height
(Note 2)
150 mm
5.906 in
230 mm
9.055 in
310 mm
12.205 in
390 mm
15.354 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
140 mm
5.512 in
220 mm
8.661 in
300 mm
11.811 in
380 mm
14.961 in
Current consumption Emitter:100 mA or less, Receiver:120 mA or less
PFHD 9.57×10-10 1.12×10-9 1.26×10-9 1.40×10-9
MTTFD 1,340 years or more 1,119 years or more 988 years or more 881 years or more
Net weight
(Total of
emitter and receiver)
270g approx. 470g approx. 680g approx. 890g approx.
Type Min. sensing object ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Model No. SF4D-H24(-01) SF4D-H28(-01) SF4D-H32(-01) SF4D-H36(-01)
Number of
beam channels
24 28 32 36
Protective height
(Note 2)
470 mm
18.504 in
550 mm
21.654 in
630 mm
24.803 in
710 mm
27.953 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
460 mm
18.110 in
540 mm
21.260 in
620 mm
24.409 in
700 mm
27.559 in
Current consumption Emitter:100 mA or less
Receiver:130 mA or less
Emitter:110 mA or less
Receiver:130 mA or less
Emitter:120 mA or less
Receiver:130 mA or less
PFHD 1.56×10-9 1.73×10-9 1.87×10-9 2.04×10-9
MTTFD 782 years or more 701 years or more 647 years or more 591 years or more
Net weight
(Total of
emitter and receiver)
1,100g approx. 1,300g approx. 1,500g approx. 1,700g approx.
Type Min. sensing object ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Model No. SF4D-H40(-01) SF4D-H48(-01) SF4D-H56(-01) SF4D-H64(-01)
Number of
beam channels
40 48 56 64
Protective height
(Note 2)
790 mm
31.102 in
950 mm
37.402 in
1,110 mm
43.701 in
1,270 mm
50.000 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
780 mm
30.709 in
940 mm
37.008 in
1,100 mm
43.307 in
1,260 mm
49.606 in
Current consumption Emitter:120 mA or less
Receiver:140 mA or less
Emitter:120 mA or less
Receiver:150 mA or less
PFHD 2.17×10-9 2.48×10-9 2.78×10-9 3.09×10-9
MTTFD 552 years or more 481 years or more 426 years or more 383 years or more
Net weight
(Total of
emitter and receiver)
1,900g approx. 2,300g approx. 2,800g approx. 3,200g approx.
Type Min. sensing object ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Model No. SF4D-H72(-01) SF4D-H80(-01) SF4D-H88(-01) SF4D-H96(-01)
Number of
beam channels
72 80 88 96
Protective height
(Note 2)
1,430 mm
56.299 in
1,590 mm
62.598 in
1,750 mm
68.898 in
1,910 mm
75.197 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
1,420 mm
55.906 in
1,580 mm
62.205 in
1,740 mm
68.504 in
1,900 mm
74.803 in
Current consumption Emitter:120 mA or less
Receiver:150 mA or less
Emitter:120 mA or less
Receiver:160 mA or less
PFHD 3.39×10-9 3.69×10-9 4.00×10-9 4.30×10-9
MTTFD 347 years or more 318 years or more 293 years or more 272 years or more
Net weight
(Total of
emitter and receiver)
3,600g approx. 4,000g approx. 4,400g approx. 4,800g approx.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years).
2) When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.

SF4D-A□(-01)(Arm / Foot protection type)

Type Min. sensing object ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Model No. SF4D-A4(-01) SF4D-A6(-01) SF4D-A8(-01) SF4D-A10(-01)
Number of
beam channels
4 6 8 10
Protective height
(Note 2)
150 mm
5.906 in
230 mm
9.055 in
310 mm
12.205 in
390 mm
15.354 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
120 mm
4.724 in
200 mm
7.874 in
280 mm
11.024 in
360 mm
14.173 in
Current consumption Emitter:100 mA or less, Receiver:120 mA or less
PFHD 8.29×10-10 9.34×10-10 1.01×10-9 1.11×10-9
MTTFD 1,577 years or more 1,378 years or more 1,267 years or more 1,136 years or more
Net weight
(Total of
emitter and receiver)
270g approx. 470g approx. 680g approx. 890g approx.
Type Min. sensing object ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Model No. SF4D-A12(-01) SF4D-A14(-01) SF4D-A16(-01) SF4D-A18(-01)
Number of
beam channels
12 14 16 18
Protective height
(Note 2)
470 mm
18.504 in
550 mm
21.654 in
630 mm
24.803 in
710 mm
27.953 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
440 mm
17.323 in
520 mm
20.472 in
600 mm
23.622 in
680 mm
26.772 in
Current consumption Emitter:100 mA or less, Receiver:130 mA or less
PFHD 1.18×10-9 1.29×10-9 1.36×10-9 1.46×10-9
MTTFD 1,060 years or more 966 years or more 910 years or more 840 years or more
Net weight
(Total of
emitter and receiver)
1,100g approx. 1,300g approx. 1,500g approx. 1,700g approx.
Type Min. sensing object ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Model No. SF4D-A20(-01) SF4D-A24(-01) SF4D-A28(-01) SF4D-A32(-01)
Number of
beam channels
20 24 28 32
Protective height
(Note 2)
790 mm
31.102 in
950 mm
37.402 in
1,110 mm
43.701 in
1,270 mm
50.000 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
760 mm
29.921 in
920 mm
36.220 in
1,080 mm
42.520 in
1,240 mm
48.819 in
Current consumption Emitter:100 mA or less
Receiver:130 mA or less
Emitter:100 mA or less
Receiver:140 mA or less
Emitter:110 mA or less
Receiver:140 mA or less
PFHD 1.54×10-9 1.71×10-9 1.89×10-9 2.07×10-9
MTTFD 798 years or more 710 years or more 640 years or more 582 years or more
Net weight
(Total of
emitter and receiver)
1,900g approx. 2,300g approx. 2,800g approx. 3,200g approx.
Type Min. sensing object ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Model No. SF4D-A36(-01) SF4D-A40(-01) SF4D-A44(-01) SF4D-A48(-01)
Number of
beam channels
36 40 44 48
Protective height
(Note 2)
1,430 mm
56.299 in
1,590 mm
62.598 in
1,750 mm
68.898 in
1,910 mm
75.197 in
  When using as safety equipment
for Chinese press machine
or when using SF4D-□-01 for
Japanese press machine or
paper shearing machine
1,400 mm
55.118 in
1,560 mm
61.417 in
1,720 mm
67.717 in
1,880 mm
74.016 in
Current consumption Emitter:110 mA or less
Receiver:150 mA or less
Emitter:110 mA or less
Receiver:160 mA or less
PFHD 2.24×10-9 2.42×10-9 2.60×10-9 2.77×10-9
MTTFD 534 years or more 493 years or more 458 years or more 428 years or more
Net weight
(Total of
emitter and receiver)
3,600g approx. 4,000g approx. 4,400g approx. 4,800g approx.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
PFHd: Probability of Dangerous Failure per Hour, MTTFd: Mean Time to Dangerous Failure (in years).
2) When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.

Return to top

Safety light curtain common specifications

Type Min. sensing object ø14 mm ø0.551 in
(10 mm 0.394 in beam pitch)
Min. sensing object ø25 mm ø0.984 in
(20 mm 0.787 in beam pitch)
Min. sensing object ø45 mm ø1.772 in
(40 mm 1.575 in beam pitch)
Model No.   SF4D-F□ SF4D-H□ SF4D-A□
Japanese press machine or paper
shearing machine compliant
SF4D-F□-01 SF4D-H□-01 SF4D-A□-01
Applicable
standards
International standards IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3)
Japan JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3)
Europe EN ISO 13849-1:2015 (Category 4, PLe), EN 55011, EN 61000-6-2, EN IEC 63000
North America ANSI/UL 61496-1/2 (Type 4),CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2
China GB/T 4584
Applicable regulations and certifications CE Marking (Machinery Directive, EMC Directive, RoHS Directive) , UKCA Marking (Machinery Regulations, EMC Regulations, RoHS Regulations) , TÜV SÜD certification (U.S.A., Canada), OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06, Korea KCs mark (Note 2)
Operating range (Note 3) Short mode: 0.2 to 7 m 0.656 to 22.966 ft
Long mode: 0.8 to 12 m 2.625 to 39.370 ft
(selectable by DIP switch)
Short mode: 0.2 to 9 m 0.656 to 29.528 ft
Long mode: 0.8 to 15 m 2.625 to 49.213 ft
(selectable by DIP switch)
Min. sensing object (Note 4) ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object ø45 mm ø1.772 in opaque object
Effective aperture angle ±2.5° or less at a sensing range of 3 m 9.843 ft or longer (based on IEC 61496-2)
Supply voltage 24 V DC+20-30 % Ripple P-P 10 % or less (excluding voltage drop due to cable) (Note 5)
Control outputs
(OSSD 1, OSSD 2)
PNP open-collector transistor / NPN open collector transistor (selectable)

<PNP output selected>
・Maximum source current: 350 mA
・Applied voltage: Same as supply voltage
(between control output and +V)
・Residual voltage: 2 V or less (source current 350 mA)
(excluding voltage drop due to cable)
・Leakage current: 0.2 mA or less (including power OFF state)
・Maximum load capacity: 2.2 μF
・Load wiring resistance: 3 Ω or less

<NPN output selected>
・Maximum sink current: 350 mA
・Applied voltage: Same as supply voltage
(between control output and 0 V)
・Residual voltage: 2 V or less (sink current 350 mA)
(excluding voltage drop due to cable)
・Leakage current: 0.2 mA or less (including power OFF state)
・Maximum load capacity: 2.2 μF
・Load wiring resistance: 3 Ω or less
  Operation mode ON when all beams are received, OFF when one or more beams are blocked
(Also OFF when internal sensor error or synchronization signal error occurs) (Note 6)
Protection circuit Incorporated
Response time OFF response: 10 ms or less (Not connected in series / parallel), 18 ms or less (Connected in series / parallel) (Note 7)
ON response: 50 ms or less (Note 8) (Note 9)
Auxiliary output (AUX)
(Non-safety output)
PNP open-collector transistor / NPN open collector transistor (selectable)

<PNP output selected>
・Maximum source current: 60 mA
・Applied voltage: Same as supply voltage
(between auxiliary output and +V)
・Residual voltage: 2 V or less (source current 60 mA)
(excluding voltage drop due to cable)
・Leakage current: 0.2 mA or less (including power OFF state)

<NPN output selected>
・Maximum sink current: 60 mA
・Applied voltage: Same as supply voltage
(between auxiliary output and 0 V)
・Residual voltage: 2 V or less (sink current 60 mA)
(excluding voltage drop due to cable)
・Leakage current: 0.2 mA or less (including power OFF state)
  Operation mode Control output ON: OFF, Control output OFF: ON (Note 6)
Protection circuit Incorporated
Response time OFF response: 60 ms or less, ON response: 60 ms or less
Synchronization method Line synchronization / optical synchronization (selectable by DIP switch)
Interference prevention
function
<Not connected in series/parallel>
・Line synchronization: 2 units or less (auto)
・Optical synchronization: 2 units or less (selectable by DIP switch)

<Connected in series/parallel>
・Series connection: 5 units or less (total number of beam channels 256 or less)
・Parallel connection: 3 units or less (total number of beam channels 192 or less) (Note 6)
・Series / parallel connection mixed: 5 units or less (total number of beam channels 144 or less) (Note 6)
Test input function Incorporated
Interlock function Incorporated [Manual reset / auto reset (selectable by wiring)] (8-core cable or 12-core cable)
Lockout release function Incorporated
External device monitor function Incorporated (8-core cable or 12-core cable)
Application indicator function Incorporated (only the receiver lights up when optical synchronization is used)
Muting function Incorporated (12-core cable)
Override function Incorporated (12-core cable)
Power save function Incorporated
Optional functions (Note 10)
(Excluding SF4D-□-01)
Fixed blanking function, floating blanking function, interlock setting function, external device monitoring setting function, auxiliary output setting function, application indicator setting function, muting setting function, override setting function, protect function, I/O setting function
Pollution degree 3
Operating altitude 2,000 m 6,561.68 ft or less (Note 11)
Environmental
resistance
Degree of protection IP67, IP65 (IEC), NEMA Type 13 (NEMA 250)
Ambient temperature -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
Ambient humidity 30 to 85 % RH, Storage: 30 to 95 % RH
Ambient illumination Incandescent light: 5,000 ℓx or less at the light-receiving surface
Dielectric strength voltage 1,000 V AC for one minute, between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz, 0.75 mm 0.030 in double amplitude in X, Y, and Z directions for two hours each
Malfunction resistance 10 to 55 Hz, 0.75 mm 0.030 in double amplitude in X, Y, and Z directions twenty times each
Shock resistance 300 m/s2 acceleration (30 G approx.) in X, Y, and Z directions three times each
Malfunction resistance 100 m/s2 acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each
SFF (Safe Failure Fraction) 99%
HFT (Hardware Fault Tolerance) 1
Subsystem type Type B (IEC 61508-2)
T1 (proof test interval) 20 years
Failure response time Within response time (OFF response)
Safety state Control output (OSSD 1 / 2) OFF state
Emitter element Infrared LED (peak emission wavelength: 850 nm 0.034 mil)
Material Enclosure: Aluminum, Detection surface: Polycarbonate resin and stainless steel (SUS304), Upper cap / lower cap: Nylon
Connecting method By connector
Cable extension Total length of emitter / receiver can be extended up to 70 m 229.659 ft each using optional mating cable (including the length of cables for series connection) (Note 5)
Accessories SF4B-TR14 (test rod): 1 pc. SF4B-TR25 (test rod): 1 pc. -

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Except for SF4D-□-01, Korea KCs mark is acquired.
3) The operating range is the possible setting distance between the emitter and the receiver.
4) When the floating blanking function is used, the size of the minimum sensing object varies. For the detail, refer to the section on Safety distance.
5) The power supply unit must satisfy the following requirements:
1) The power unit must be certified for use in your region.
2) Use of the product as a unit in compliance with CE Marking: SELV (safety extra low voltage) / PELV (protected extra low voltage) power supply unit in conformity with EMC Directive and Low Voltage Directive.
3) Use of the product as a unit in compliance with UKCA Marking: SELV (safety extra low voltage) / PELV (protected extra low voltage) power supply unit in conformity with EMC Regulations and Low Voltage Regulations.
4) When using a commercial switching regulator, the frame ground (F.G.) terminal must be connected to ground.
5) The power supply unit must have an output holding time of 20ms or more.
6) If surges occur, take countermeasures such as connecting a surge absorber to the source of the surges.
7) The power unit must be a CLASS 2 compliant unit. (When CTÜVUS mark compliance is required.)
6) In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline.
7) The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. Note that the setting cannot be changed when SF4D-□-01 is used.
8) For response times by number of beams, refer to the Control output (OSSD 1, OSSD 2) OFF response times.
9) Because the control output (OSSD 1, OSSD 2) must be OFF for at least 80 ms, the ON response will be delayed more than 50 ms when the light blocked time is less than 30 ms.
10) When optical synchronization is selected, if the beam axes of both the top end and bottom end are blocked, the ON response speed decreases by as much as 1 sec.
11) To use optional functions, the SF4D-TM1 (optional) and Configurator Safety Light Curtain setting software are required. Note that optional functions cannot be used when SF4D-□-01 is used.
12) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.

Control output (OSSD 1, OSSD 2) source / sink current and cable length

Number of
sub-sensors
Control output
(OSSD 1, OSSD 2)
source / sink current
Power supply cable length
Length of cable for series
connection
(Total cable length)
Cable
Power supply cable
length
Cable length for
series connection
0
(No series
connection)
100 mA 70 m 229.659 ft or less - -
200 mA
350 mA 10.5 m 34.449 ft or less
1 100 mA 50 m 164.042 ft or less - Cable length obtained by
subtracting power supply
cable length from total
cable length
200 mA
350 mA 10.5 m 34.449 ft or less
2 100 mA 50 m 164.042 ft or less -
200 mA
350 mA 10.5 m 34.449 ft or less
3 100 mA 50 m 164.042 ft or less -
200 mA 40.5 m 132.874 ft or less
350 mA 10.5 m 34.449 ft or less
4 100 mA 25.5 m 83.661 ft or less -
200 mA 20.5 m 67.257 ft or less
350 mA 10.5 m 34.449 ft or less

* Power supply cable: Cable consisting of the bottom cap cable (optional) and extension cable (optional)

Control output (OSSD 1, OSSD 2) OFF response times

  OFF response time
Main
sensor
Sub sensor
Number of
units connected
in series
1 unit 1 unit 2 units 3 units 4 units 0 unit 0 unit 1 unit 1 unit 2 units 2 units 3 units
Number of
units connected
in parallel
0 unit 0 unit 0 unit 0 unit 1 unit 2 units 1 unit 2 units 1 unit 2 units 1 unit
Total number
of beams
4 to 48 6ms 10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
49 to 96 8ms 10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
97 to 127 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
128 to 144 - 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
145 to 192 - 14ms 14ms 16ms 16ms 14ms 14ms - - - - -
193 to 256 - 16ms 16ms 18ms 18ms - - - - - - -

・Example of series connection
5 units or fewer (Total number of beam channels must be 256 or less.)

Example of series connection

・Example of combination of series connection and parallel connection
5 units or fewer (Total number of beam channels must be 144 or less.)

Example of combination of series connection and parallel connection
Note: Refer to the manual on our website for details

When SF4D-□-01 is used, parallel connection or combination of series connection and parallel connection cannot be used.
In the case of parallel connection or combination of series connection and parallel connection, it is necessary to change settings by using the SF4D-TM1 communication module (optional) and Configurator Safety Light Curtain setting software.

Return to top

Control units

For specifications of the control units, please see each product page.

>>"Safety Control Unit SF-C21"
>>"Exclusive Control Unit for Safety Light Curtain SF-C10"

IO-Link communication unit

Product name IO-Link communication unit for safety light curtain SF4D series
Model No. SFD-WL3
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Communication
method
Safety light curtain
communication side
RS-485 bidirectional communication (dedicated protocol)
IO-Link
communication side
IO-Link specifications: Ver. 1.1
Baud rate: COM3 (230.4 kbps)
Data length: 18 bytes, process data (PD)
Minimum cycle time: 1.5 ms
Supply
voltage
Safety light curtain
communication side
24V DC +20-30 % Ripple P-P 10 % or less
IO-Link
communication side
24V DC +20-25 % Ripple P-P 10 % or less
Current
consumption
Safety light curtain
communication side
15 mA or less
IO-Link
communication side
30 mA or less
Functions • IO-Link communication function
• Safety light curtain setting data copy function (Note 2, 3, 4)
Number of
connectable
units
This product 1 unit
Safety light curtains
in series connection
Up to 5 units (total number of beam channels 256 or less)
Pollution degree / Excess voltage category 3 / I
Operating altitude 2,000 m 6561.68 ft or less (Note 5)
Environmental
resistance
Protection IP64 (IEC)
Ambient temperature -10 to +55℃ 14 to 131℉
(No dew condensation or icing allowed),
Storage: -25 to +60℃ -13 to 140℉
Ambient humidity 30 to 85% RH, Storage: 30 to 95% RH
Dielectric
strength voltage
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation
resistance
20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure
Vibration
resistance
10 to 55 Hz, 0.75 mm 0.030 in double amplitude in X, Y, and Z directions for two hours each
Malfunction resistance 10 to 55 Hz, 0.75 mm 0.030 in double amplitude in X, Y, and Z directions twenty times each
Shock
resistance
300 m/s2 acceleration (30 G approx.) in X, Y, and Z directions three times each
Malfunction resistance 100 m/s2 acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each
Material Main unit case: PA66 (with glass)
Base plate: SPCC + Plating
Product model nameplate: Polyester
External connection connector: Brass + Plating
Connection
method
Safety light curtain
communication side
8-core cable for safety light curtain (optional)
IO-Link
communication side
4-core cable with M12 connector
(commercially available product)
Weight Net weight: 270 g approx., Gross weight: 340 kg approx.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) This function is designed for use in maintenance and replacement of safety light curtain. If different setting information is written, the unit may not operate properly.
3) The internal memory (nonvolatile) of this product has a service life. Settings cannot be configured more than 100,000 times.
4) This function cannot be used unless the product is connected with the IO-Link master unit and IO-Link communication is used.
5) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
6) The product and IO-Link master unit must be connected with a cable of 0.3 mm2 or more. The total length of the cable must not exceed 20 m 65.62 ft.

Return to top

Communication module

Model No. SF4D-TM1
Communication system Safety light curtain side: RS-485 bilateral communication (dedicated protocol)
PC side: USB
Connection system Safety light curtain side: Connector
PC side: USB (Mini-B male)
Protection IP40 (IEC)
Ambient temperature -10 to +55 ℃ +14 to +131 ℉ (no dew condensation or icing allowed),
Storage: -25 to +60 ℃ -13 to +140 ℉
Ambient humidity 30 to 85% RH, Storage: 30 to 95% RH
Usable altitude 2,000 m 6,561.68 ft or lower (Note 2)
Cable 1.5 m 4.921 ft cable with connector (safety light curtain side) (Note 3)
Weight Net weight: 75 g approx.

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
3) USB cable is not provided with the product. USB2.0 cable (A: Mini-B) must be prepared by the user.

Return to top

Laser alignment tool

Model No. SF-LAT-2N
Supply voltage 3 V (LR6 battery x 2 pcs.)
Battery 1.5 V (LR6 battery) x 2 pcs. (replaceable)(Note 2)
Battery lifetime 30 hours approx. of continuous operation
(LR6 battery, at +25 ℃ +77 ambient temperature)
Light source Red semiconductor laser: class 2 (IEC / JIS), Class II (FDA)
(Max. output: 1 mW, Peak emission wavelength: 650 nm 0.026 mil)(Note 3)
Spot diameter 10 mm 0.394 in approx. (at 5 m 16.404 ft distance)
Ambient temperature 0 to +40 ℃ +32 to +104 (No dew condensation),
Storage: 0 to +55 ℃ +32 to +131
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Material Enclosure: ABS, Mounting part: Aluminum
Weight Net weight: 150 g approx. (without batteries)

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 .
2) LR6 dry cell batteries are not provided with the product. Please purchase them separately.
3) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.

Corner mirror

Model No. RF-SFBH-□
Attenuation rate of operating range With one corner mirror: Declined to 90 %, With two corner mirrors: Declined to 80 %, With three corner mirrors: Declined to 70 % (When used in combination with the SF4D series)
Environmental
resistance
Ambient temperature –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +70 ℃ –13 to +158 ℉
Ambient humidity 30 to 85 % RH, Storage: 30 to 95 % RH
Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Material Enclosure: Aluminum, Mounting bracket: Stainless steel, Mirror (rear surface mirror): Glass, Side cover: EPDM
Accessories Intermediate supporting bracket: 1 set (RF-SFBH-40/48/56/64), 2 sets (RF-SFBH-72/80/88/96)

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) The corner mirror has not received type examination by the Ministry of Health, Labour and Welfare; therefore, it cannot be used for presses or shearing machines (paper cutting machines) in Japan.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)