Safety door switch with key SG-B2

Specifications

Designation Safety door switch with key
Series SG-B2 series
Applicable
standards
EN 60947-5-1, GS-ET-19
  Standards for use IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14
Applicable regulations CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations]
Operating
condition
Ambient
temperature
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed)
Storage: -40 to +80 ℃ -40 to +176 ℉
Ambient humidity 45 to 85 % RH
Pollution degree 3 (Inside 2)
Altitude 2,000 m 6,561.68 ft max.
Impulse withstand
voltage (Uimp)
2.5 kV
Rated insulation
voltage (Ui)
250 V (Note 1)
Thermal current
(Ith)
2.5 A
Ambient temperature:
-25 to +60 ℃ -13 to +140 ℉: 2.5 A max.
+60 to +65 ℃ +140 to +149 ℉: 1.5 A max.
+65 to +70 ℃ +149 to +158 ℉: 1.0 A max.
Rated operational
voltage (Ue) /
Rated operational
current (Ie)
  Ue
30V 125V 250V
Ie AC Resistive load (AC-12) - 2.5A 1.5A
Inductive load (AC-15) - 1.5A 0.75A
DC Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive load (DC-13) 2.3A 0.55A 0.27A
Operating frequency 900 operations/hour
Actuator operating speed 0.05 to 1.0 m/sec.
B10d 2,000,000
(ISO 13849-1 Annex C Table C.1)
Mechanical
durability
1,000,000 operations min. (GS-ET-19)
Rear unlocking button: 3,000 operations min. (Type SG-B2-□-L5)
Electrical
durability
100,000 operations min. (AC-12, 250 V 1 A)
1,000,000 operations min. (AC/DC 24 V 100 mA)
(900 operations/hour)
Electric shock
protection class
Class II (IEC 61140) (Note 2), 回(double-insulated)
Interlock force 1,400 N min. (GS-ET-19) (Note 3)
(500 N min. : SG-K24 actuator)
Direct opening
travel
11 mm 0.433 in min. (actuator: SG-K21)
12 mm 0.472 in min. (for other actuators)
Direct opening force 80 N min.
Contact resistance 700 mΩ max. (initial value, 5 m 16.404 ft cable)
Protection IP 65 (IEC 60529)
Shock resistance Malfunction: 100 m/s2, Destruction: 1,000 m/s2
Vibration
resistance
Malfunction: 10 to 55 Hz, half amplitude 0.35 mm 0.014 in
Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in
Conditional
short-circuit current
50 A (250 V)
Short-circuit
protective device
Use 250 V / 10 A fast acting type fuse
Material Enclosure: PA66
Cable UL style 2464, No.22 AWG 12-core
Key Operating
specifications
2 positions
Mechanical
durability
100,000 operations min.
Key operating
durability
10,000 operations min.
Key tensile
strength
1.0 N・m min.
Direct opening
force
0.6 N・m min.
Direct opening
degree
60°min.
Weight SG-B2-□-5: Approx. 680 g, SG-B2-□-L5: Approx. 700 g

Notes:

1) Ratings approved by UL, c-UL: 125 V
2) Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.
When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more.
3) The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)