AUTOMATION
CONTROLS

Search
Discontinued
Products



HG-TC111 | Thru-beam Type Digital Displacement Sensor HG-T


Thru-beam Type Digital Displacement Sensor HG-T

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


Product Number HG-TC111
Part Number HG-TC111
Product Controller
Details Slave unit / High performance type
Product name Thru-beam Type Digital Displacement Sensor HG-T

As of April 20, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number HG-TC111
Part Number HG-TC111
Regulatory compliance CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Pollution degree 2
Operating altitude 2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Environmental resistance : Protection IP40(IEC)
Environmental resistance : Ambient temperature -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃ -4 to +140 ℉
(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.
Number of connected slave units Maximum sink current and source
current of control output
Ambient temperature
  When communication unit
is connected
1 to 7 units 1 to 6 units 20 mA -10~+45℃
+14 to +113 ℉
8 to 15 units 7 to 14 units 10 mA
Environmental resistance : Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Environmental resistance : Voltage withstandability 1,000 V AC for one minute between all supply terminals connected together and enclosure
Environmental resistance : Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Environmental resistance : Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Environmental resistance : Shock resistance 98m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Material Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Cable 0.15 mm2 7-core composite cable, 2 m 6.562 ft long
Net weight 140 g approx.
Applicable sensor head HG-T1010、HG-T1110
Maximum number of connectable controllers Up to 15 slave units can be connected to a master unit.
(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Supply voltage 24 V DC ±10 %, including ripple 0.5 V (P-P)
Current consumption 100 mA or less (when sensor head is connected)
(Note) : Current consumption does not include analog current output.
Analogue output : Analog voltage output •Voltage output range: 1 to 5 V/F.S. (default value)
•Linearity: ±0.05 % F.S.
•Output when alarm occurs: 5.2 V
•Output impedance: 100 Ω max.
(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Analogue output : Analog current output •Current output range: 4 to 20 mA/F.S. (default value)
•Linearity: ±0.25 % F.S.
•Output when alarm occurs: 0 mA
•Load impedance: 250 Ω max.
(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Control output(Output 1, Output 2, Output 3) NPN open-collector transistor
•Maximum sink current: 50 mA (Note)
•Applied voltage: 30 V DC or less (between output and 0 V)
•Residual voltage: 1.5 V or less (at 50 mA sink current)
•Leakage current: 0.1 mA or less


PNP open-collector transistor
•Maximum source current: 50 mA (Note)
•Applied voltage: 30 V DC or less (between output and +V)
•Residual voltage: 1.5 V or less (at 50 mA source current)
•Leakage current: 0.1 mA or less

(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.
Number of connected slave units Maximum sink current and source
current of control output
Ambient temperature
  When communication unit
is connected
1 to 7 units 1 to 6 units 20 mA -10~+45℃
+14 to +113 ℉
8 to 15 units 7 to 14 units 10 mA
Control output(Output 1, Output 2, Output 3) : Short-circuit protection Incorporated (automatic reset type)
Control output(Output 1, Output 2, Output 3) : Judgment output N.O. / N.C. switching type
Control output(Output 1, Output 2, Output 3) : Alarm output Open when alarm occurs
External output switching Output 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2.
External input(Input 1, Input 2, Input 3)
Non-contact input or NPN open-collector transistor
•Input conditions
Invalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC
•Input impedance: 10 kΩ approx.


Non-contact input or PNP open-collector transistor
•Input conditions
Invalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC
•Input impedance: 10 kΩ approx.
External input(Input 1, Input 2, Input 3) : Input time • Trigger input: 2 ms or more (ON)
• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)
(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
External input switching Input 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop".
Sampling rate 1 ms (standard sampling) / 0.5 ms (high-speed sampling)
Average count (response time) 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type
(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Display resolution 1 μm 0.039 mil
Display range -199.999 to 199.999 mm -7.874 to 7.874 in

Return to top

Accessories (Option)

Communication Unit for Digital Displacement Sensors SC-HG1
Product Number SC-HG1-485
Part Number SC-HG1-485
Product RS-485 Communication Unit for Digital Displacement Sensors
Product name Communication Unit for Digital Displacement Sensors SC-HG1
Communication Unit for Digital Displacement Sensors SC-HG1
Product Number SC-HG1-C
Part Number SC-HG1-C
Product CC-Link Communication Unit for Digital Displacement Sensors
Product name Communication Unit for Digital Displacement Sensors SC-HG1
Communication Unit for Digital Displacement Sensors SC-HG1
Product Number SC-HG1-CEF
Part Number SC-HG1-CEF
Product CC-Link IE Field Communication Unit for HG series
Product name Communication Unit for Digital Displacement Sensors SC-HG1


More



Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)