Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Microwave Devices > Microwave Devices Lineup > RJ Relays > Rating/Performance
|
Rated coil voltage | Operate voltage * (at 20°C) |
Release voltage * (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 70°C) |
---|---|---|---|---|---|---|
3 V DC | Max. 75% V of rated coil voltage (Initial) |
Min. 10% V of rated coil voltage (Initial) |
66.7 mA | 45 Ω | 200 mW | 110% V of rated coil voltage |
4.5 V DC | 44.4 mA | 101.2 Ω | ||||
12 V DC | 16.7 mA | 720 Ω | ||||
24 V DC | 8.3 mA | 2,880 Ω |
* | Square, pulse drive |
---|
Rated coil voltage |
Set voltage * (at 20°C) |
Reset voltage * (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 70°C) |
---|---|---|---|---|---|---|
3 V DC | Max. 75% V of rated coil voltage (Initial) |
Max. 75% V of rated coil voltage (Initial) |
50 mA | 60 Ω | 150 mW | 110% V of rated coil voltage |
4.5 V DC | 33.3 mA | 135 Ω | ||||
12 V DC | 12.5 mA | 960 Ω | ||||
24 V DC | 6.3 mA | 3,840 Ω |
* | Square, pulse drive |
---|
Item | Specifications | |
---|---|---|
Contact data | Contact arrangement | 2 Form C |
Contact resistance (initial) |
Max. 150 mΩ (by voltage drop 10 V C 10 mA) | |
Contact material | Au plating | |
Contact rating | 1 W (5 GHz, 50 Ω, V.S.W.R.: Max. 1.25), 10 mA 10 V DC (resistive) | |
Contact input power (CW) | Max. 1 W (1 GHz, 50 Ω, V.S.W.R.: Max. 1.25) | |
Max. switching voltage | 30 V DC | |
Max. switching current | 0.3 A (DC) | |
Insulation resistance (initial) | 500 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | |
Dielectric strength (initial) |
Between open contacts | 500 Vrms for 1 min (detection current: 10 mA) |
Between contact and coil | 500 Vrms for 1 min (detection current: 10 mA) | |
Between contact sets | 500 Vrms for 1 min (detection current: 10 mA) | |
Between contact and ground | 500 Vrms for 1 min (detection current: 10 mA) | |
Time characteristics (initial) |
Operate (Set) time | Max. 5 ms at rated coil voltage (at 20°C, without bounce) [Max. 5 ms (at 20°C, without bounce)] |
Release (Reset) time | Max. 5 ms at rated coil voltage (at 20°C, without bounce, without diode) [Max. 5 ms (at 20°C, without bounce)] |
|
Shock resistance | Functional | 500 m/s2 (half-sine shock pulse: 6 ms, detection time: 10 μs) |
Destructive | 1,000 m/s2 (half-sine shock pulse: 11 ms) | |
Vibration resistance | Functional | 10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs) |
Destructive | 10 to 55 Hz (at double amplitude of 5 mm) | |
Expected life | Mechanical life (Cold switch) |
Max. 10 x 106 (Switching frequency: 180 times/min) |
Conditions | Conditions for usage, transport and storage * |
Ambient temperature: -30 to +70 °C (Allowable temperature is from -30 to +60 °C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 3 g |
* | *For ambient temperature, please read "GUIDELINES FOR RELAY USAGE". |
---|
Conditions: Resistive load, switching frequency 20 times/min
Type | Load | Switching capacity | Number of operations |
---|---|---|---|
2 Form C | High frequency load | 1 W (5 GHz, 50 Ω, V.S.W.R.: Max. 1.25) | Max. 106 |
Resistive load | 10 mA 10 V DC | Max. 106 |
|