3 GHz capable, 10 W carrying power (at 3 GHz), 50/75 Ω, 1 Form C Relays
Protective construction: Sealed type
Please refer to "the latest product specifications" when designing your product.
Please refer to "Cautions For Use" in the catalog, and "Related Information" on our website.
Features
1.Excellent high frequency characteristics (50/75 Ω, up to 3 GHz)
2.Lineup includes quiet type and reversed contact type.
3.Compact size: 8.6 (W) x 14 (L) x 8 (H) mm
Typical Applications
1.Broadcasting and video equipment
2.Communication and measurement equipment
3.Mobile phone base stations
4.Measurement equipment market
Note: If you consider using applications with low level loads or with high frequency switching, please consult us.
High Frequency Characteristics
50 Ω (Initial)
PC board terminal
Frequency |
Up to 900 MHz |
Up to 3 GHz |
V.S.W.R. (Max.) |
1.2 |
1.4 |
Insertion loss (dB, Max.) |
0.1 |
0.35 |
Isolation (dB, Min.) |
60 |
35 |
Surface mount terminal
Frequency |
Up to 900 MHz |
Up to 3 GHz |
V.S.W.R. (Max.) |
1.2 |
1.4 |
Insertion loss (dB, Max.) |
0.2 |
0.4 |
Isolation (dB, Min.) |
55 |
30 |
75 Ω (Initial)
PC board terminal
Frequency |
Up to 900 MHz |
Up to 3 GHz |
V.S.W.R. (Max.) |
1.15 |
1.4 |
Insertion loss (dB, Max.) |
0.1 |
0.3 |
Isolation (dB, Min.) |
60 |
30 |
Surface mount terminal
Frequency |
Up to 900 MHz |
Up to 3 GHz |
V.S.W.R. (Max.) |
1.2 |
1.5 |
Insertion loss (dB, Max.) |
0.2 |
0.5 |
Isolation (dB, Min.) |
55 |
30 |
Reference Data
1-1. High frequency characteristics (50 Ω, PC board terminal)
Sample: ARS144H
Measuring method: See "Measuring method" under "NOTES".
1-2. High frequency characteristics (75 Ω, PC board terminal)
Sample: ARS104H
Measuring method: See "Measuring method" under "NOTES".
1-3. High frequency characteristics (50 Ω, Surface mount terminal)
Sample: ARS14A4H
Measuring method: See "Measuring method" under "NOTES".
1-4. High frequency characteristics (75 Ω, Surface mount terminal)
Sample: ARS10A4H
Measuring method: See "Measuring method" under "NOTES".
2-1. Distribution of operation noise
Sample |
: |
ARS134H (single side stable quiet type), 50 pcs. |
Coil voltage |
: |
rated voltage applied (with diode) |
Equipment setting |
: |
A weighted sound pressure level, FAST. |
Background noise |
: |
approx. 20 dB |
Method of measurement |
: |
See figure below. |
2-2. Distribution of operation noise
Sample |
: |
ARS104H (single side stable standard type), 50 pcs. |
Coil voltage |
: |
rated voltage applied (with diode) |
Equipment setting |
: |
A weighted sound pressure level, FAST. |
Background noise |
: |
approx. 20 dB |
Method of measurement |
: |
See figure below. |
2-3. Distribution of operation noise
Sample |
: |
ARS114H (latching type), 50 pcs. |
Coil voltage |
: |
rated voltage applied (with diode) |
Equipment setting |
: |
A weighted sound pressure level, FAST. |
Background noise |
: |
approx. 20 dB |
Method of measurement |
: |
See figure below. |
Return to top