AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS GU SOP 1 Form B (SOP4-pin type)


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol AQY412S AQY410S AQY414S Remarks
Input LED forward current IF 50mA
LED reverse voltage VR 5V
Peak forward current IFP 1A f=100Hz, Duty Ratio=0.1%
Power dissipation Pin 75mW
Output Load voltage (peak AC) VL 60V 350V 400V
Continuous load current IL 0.5A 0.12A 0.1A Peak AC, DC
Peak load current Ipeak 1.5A 0.3A 0.24A 100ms(1 shot), VL=DC
Power dissipation Pout 300mW
Total power dissipation PT 350mW
I/O isolation voltage Viso 1,500Vrms
Ambient temperature (Operating) Topr -40 to +85°C (Avoid icing and condensation)
Ambient temperature (Storage) Tstg -40 to +100°C
Junction temperature Tj 125°C

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol AQY412S AQY410S AQY414S Condition
Input LED operate (OFF) current Typical IFoff 0.9mA IL=Max.
Maximum 3mA
LED reverse (ON) current Minimum IFon 0.4mA
Typical 0.85mA
LED dropout voltage Typical VF 1.25V (1.14V at IF=5mA) IF=50mA
Maximum 1.5V
Output On resistance Typical Ron 18Ω 26Ω IF=0mA
IL=Max.
Within 1s
Maximum 2.5Ω 25Ω 35Ω
Off state leakage current Maximum ILeak 1μA IF=5mA
VL=Max.
Transfer characteristics Operate (OFF) time* Typical Toff 0.9ms 0.52ms 0.47ms IF=0mA→5mA
IL=Max.
Maximum 3ms 1ms
Reverse (ON) time* Typical Ton 0.21ms 0.23ms 0.28ms IF=5mA→0mA
IL=Max.
Maximum 1ms
I/O capacitance Typical Ciso 0.8pF f=1MHz
VB=0V
Maximum 1.5pF
Initial I/O isolation resistance Minimum Riso 1,000MΩ 500V DC
*Operate/Reverse time
Operate/Reverse time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 5 30 mA
AQY412S Load voltage (Peak AC) VL - 48 V
Continuous load current IL - 0.5 A
AQY410S Load voltage (Peak AC) VL - 280 V
Continuous load current IL - 0.12 A
AQY414S Load voltage (Peak AC) VL - 320 V
Continuous load current IL - 0.1 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)