Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > Power Relays (Over 2A) Lineup > HE-N Relays > Rating/Performance
|
Rated coil voltage | Operate voltage* (at 20°C) |
Release voltage* (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power | Max. allowable voltage (at55°C) |
---|---|---|---|---|---|---|
6 V DC | Max.75% V of Rated coil voltage (Initial) |
Min.5% V of Rated coil voltage (Initial) |
417 mA | 14.4 Ω | 2,500 mW | 110% V of Rated coil voltage |
9 V DC | 278 mA | 32.4 Ω | ||||
12 V DC | 208 mA | 57.6 Ω | ||||
24 V DC | 104 mA | 230 Ω |
* | square, pulse drive |
---|
Item | Specifications | |
---|---|---|
Contact data | Contact arrangement | 1 Form A |
Contact resistance (initial) | Max. 10 mΩ (by voltage drop 5 V DC 20 A) Max. 3 mΩ (by voltage drop 5 V DC 120 A, reference value) |
|
Contact material | AgNi type | |
Contact rating (resistive) | 120 A 490 V AC, 120 A 60 V DC | |
Max. switching power (resistive) | 58,800 VA, 7,200 W | |
Max. switching voltage | 800 V AC, 60 V DC | |
Max. switching current | 120 A | |
Min. switching load (reference value)*1 |
100 mA 5 V DC | |
Insulation resistance (initial) | Min.1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | |
Dielectric strength (initial) | Between open contacts | 2,000 Vrms for 1 min (detection current: 10 mA) |
Between contact and coil | 5,000 Vrms for 1 min (detection current: 10 mA) | |
Surge withstand voltage (initial)*2 | Between contact and coil | 10,000 V |
Coil holding voltage*3 | 40 to 100% V (at -40 to +55°C) 50 to 60% V (at +55 to +85°C) |
|
Time characteristics (initial) | Operate time | Max.30 ms (at rated coil voltage at 20°C, without bounce) |
Release time | Max.10 ms (at rated coil voltage at 20°C, without bounce, without diode) | |
Shock resistance | Functional | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Destructive | 980 m/s2 (half-sine shock pulse: 6 ms) | |
Vibration resistance | Functional | 10 to 55 Hz (at double amplitude of 1.0 mm, detection time: 10 μs) |
Destructive | 10 to 55 Hz (at double amplitude of 1.5 mm) | |
Expected life | Mechanical | Min. 106 ope. (at 180 times/min.) |
Conditions | Conditions for usage, transport and storage*4 |
Ambient temperature: -40 to +85°C (When using at +55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.) |
Unit weight | Approx. 115 g |
*1 | This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. |
---|---|
*2 | Wave is standard shock voltage of ±1.2 x 50 µs according to JEC-212-1981. |
*3 | Coil holding voltage is the coil voltage after 100 ms following application of the rated coil voltage. |
*4 | The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to in “NOTES” of HE-N relays catalog. |
Type | Switching capacity | Number of operations |
---|---|---|
1 Form A | 55 A 800 V AC | Min. 10 x 103 ope. (at 85°C, ON:OFF = 1 s:9 s) |
90 A 490 V AC | Min. 10 x 103 ope. (at 85°C, ON:OFF = 1 s:9 s) | |
120 A 490 V AC | Min. 103 ope. (at 85°C, ON:OFF = 1 s:9 s) | |
120 A 60 V DC | Min. 103 ope. (ON:OFF = 1 s:9 s) |
Item | Characteristics |
---|---|
Clearance/Creepage distance (IEC61810-1) | Min. 5.5 mm/8.0 mm |
Category of protection (IEC61810-1) | RT II |
Tracking resistance (IEC60112) | PTI 175 |
Insulation material group | III a |
Over voltage category | III |
Rated voltage | 800V |
Pollution degree | 2 |
Type of insulation (Between contact and coil) | Basic insulation |
Type of insulation (Between open contact) | micro disconnection |
* | Note: Actual value |
---|
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])