HE-S Relays

The application examples on this website are for reference to verify on the actual device before using.

Compact size 2a and 2a1b 40A power relays for energy management and industrial equipment

RoHS規格 UL C-UL Recognaized VDE HOUSE MARK CQC

UL/C-UL , VDE , TV , CQC Approved
CSA standard certified by C-UL
CQC standard acquisition situation changes with part number.

Protective construction: Flux-resistant type

Features

1.High-capacity and long life 35A 277V AC 5×104 (long life type)

2.Electrical life (resistive load)

Form A contact Standard type Long life type
35A 277V AC
30A 220V AC
20A 277V AC
3×104

1×105
5×104
1×105
2×105

3.Compact size and low operating power

W: 30 × L: 36 × H: 40 mm W: 1.181 × L: 1.417 × H: 1.575 inch
Operating power: 1,880 mW (holding power: 170 mW)

4.Reduced coil holding voltage contributes to saving energy of equipment

The coil holding voltage can be reduced up to 30%V of the nominal coil voltage. This equals to operating power of approximately 170 mW, which contributes equipment energy savings.
* Coil holding voltage is the coil voltage after 100 ms from the applied nominal coil voltage.

5.Contact gap: 3.2 mm .126 inch (VDE0126 compliant)

Compliant with European photovoltaic standard VDE0126
Compliant with EN61810-1 2.5 kV surge breakdown voltage (between contacts)

6.Insulation distance (initial)

• Between Form A contact and coil: Min. 11.0 mm .433 inch (Clearance/Creepage)
• Between Form B contact and coil: Min. 3.2 mm .126 inch (Clearance/Creepage)
• Between Form A contact sets: Min. 8.2 mm .323 inch (Clearance/Creepage)
• Between Form A contact and Form B contact: Min. 12.8 mm .504 inch (Clearance/Creepage)

7.Contact gap (initial)

• Form A contact:   Min. 3.2 mm .126 inch/each contact
• Form B contact:   Min. 0.7 mm .028 inch
Min. 0.5 mm .020 inch (When Form A contact welded)

8.Mirror contact mechanisms (Compliant with EN60947-4-1 mirror contact)

Detection of main contact welding makes it possible to construct a safety circuit.
• Designed so that Form A contact and Form B contact will not close at the same time.
• When Form A contact welded, Form B contact gap of at least 0.5 mm .020 inch is maintained.
* Form B contact, when used to monitor the condition of Form A contact, can be used exclusively as an auxiliary contact.

Conditions Normal operation When Form A
contact welded
Non-excitation Excitation Non-excitation
Mirror contact
mechanisms

Typical Applications

1.Photovoltaic power generation systems (Solar inverter)

2.Uninterruptible Power Supplies (UPS)

3.Inverter

4.Office air conditioner

5.Industrial equipment

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE SEARCH FAQ

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



BY PHONE

FAQ


Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)