Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > Power Relays (Over 2A) Lineup > JW Relays > Rating/Performance
|
Rated coil voltage |
Operate voltage *1 (at 20°C) |
Release voltage *1 (at 20°C) |
Rated operating current (±10%, at 20°C) |
Coil resistance (±10%, at 20°C) |
Rated operating power |
Max. allowable voltage (at 20°C) |
---|---|---|---|---|---|---|
5 V DC | Max. 70% V of rated coil voltage (Initial) |
Min. 10% V of rated coil voltage (Initial) |
106 mA | 47 Ω | 530 mW | 130% V of rated coil voltage (at 60°C: class E) 120% V of rated coil voltage (at 85°C: class B) *2 |
6 V DC | 88 mA | 68 Ω | ||||
9 V DC | 58 mA | 155 Ω | ||||
12 V DC | 44 mA | 270 Ω | ||||
24 V DC | 22 mA | 1,100 Ω | ||||
48 V DC | 11 mA | 4,400 Ω |
*1 | square, pulse drive |
---|---|
*2 | The operate and release voltages rise approximately 0.4% for every 1°C given a standard ambient temperature of 20°C. Therefore, when using relays where the ambient temperature is high, please take into consideration the rise in operate voltage and keep the coil applied voltage within the maximum allowable applied voltage. |
Item | Specifications | ||
---|---|---|---|
Standard type | High capacity type | ||
Contact data | Contact arrangement | 1 Form A, 1 Form C, 2 Form A, 2 Form C |
1 Form A, 1 Form C |
Contact resistance (Initial) |
Max. 100 mΩ (by voltage drop 6 V DC 1 A) | ||
Contact material | 1 Form A: AgSnO2 type, 1 Form C, 2 Form A, 2 Form C: AgNi type | ||
Contact rating (resistive) |
5 A 250 V AC, 5 A 30 V DC | 10 A 250 V AC, 10 A 30 V DC | |
Max. switching power (resistive) |
1,250 VA, 150 W | 2,500 VA 300 W | |
Max. switching voltage | 250 V AC, 30 V DC | ||
Max. switching current | 5 A | 10 A | |
Min. switching load (reference value) *1 |
100 mA, 5 V DC | ||
Insulation resistance (Initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | ||
Dielectric strength (initial) |
Between open contacts |
1,000 Vrms for 1 min (detection current: 10 mA) | |
Between contact sets |
2 Form A, 2 Form C: 3,000 Vrms for 1 min (detection current: 10 mA) |
- | |
Between contact and coil |
5,000 Vrms for 1 min (detection current: 10 mA) | ||
Surge withstand voltage (initial) *2 |
Between contacts and coil |
10,000 V | |
Time characteristics (initial) |
Operate time | Max. 15 ms (at rated coil voltage, at 20°C, without bounce) | |
Release time | Max. 5 ms (at rated coil voltage, at 20°C, without bounce, without diode) | ||
Shock resistance | Functional | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | |
Destructive | 980 m/s2 (half-sine shock pulse: 6 ms) | ||
Vibration resistance | Functional | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | |
Destructive | 10 to 55 Hz (at double amplitude of 2 mm) | ||
Expected life | Mechanical life | Min. 5 x 106 ope. (switching frequency: at 180 times/min) | |
Conditions | Conditions for usage, transport and storage *3 |
Ambient temperature: –40 to +60°C (Class E), –40 to +85°C (Class B) *4 Humidity: 5 to 85% RH (Avoid icing and condensation) |
|
Unit weight | Approx. 13 g |
*1 | This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. |
---|---|
*2 | Wave is standard shock voltage of ±1.2 x 50 µs according to JEC-212-1981 |
*3 | For ambient temperature, please read "6. Usage, storage, and transport conditions" in Relays Cautions For Use - 6. Ambient Environment. |
*4 | The operate and release voltages rise approximately 0.4% for every 1°C given a standard ambient temperature of 20°C. Therefore, when using relays where the ambient temperature is high, please take into consideration the rise in operate voltage and keep the coil applied voltage within the maximum allowable applied voltage. |
Conditions: Resistive load, at 20°C, Flux-resistant: at 20 times/min, Sealed: at 6 times/min
Type | Switching capacity | Number of operations |
---|---|---|
1 Form A, 1 Form C, 2 Form A, 2 Form C (Standard) |
5 A 250 V AC | Min. 100 x 103 ope. |
5 A 30 V DC | Min. 100 x 103 ope. | |
1 Form A, 1 Form C (High capacity) |
10 A 250 V AC | Min. 100 x 103 ope. |
10 A 30 V DC | Min. 100 x 103 ope. |
|