AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS GU 1 Form A Short Circuit Protection


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol AQV112KL(A) Remarks
Input LED forward current IF 50mA
LED reverse voltage VR 5V
Peak forward current IFP 1A f=100Hz,
Duty Ratio=0.1%
Power dissipation Pin 75mW
Output Load voltage (DC) VL 7 to 60V
Continuous load current (DC) IL 0.5A
Power dissipation Pout 500mW
Total power dissipation PT 550mW
I/O isolation voltage Viso 1,500Vrms
Ambient temperature (Operating) Topr -40 to +85°C (Avoid icing and condensation)
Ambient temperature (Storage) Tstg -40 to +100°C
Junction temperature Tj 125°C

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol AQV112KL(A) Condition
Input LED operate current Typical IFon 0.8mA IL=100mA
Maximum 10mA
LED turn off current Minimum IFoff 0.3mA
Typical 0.7mA
LED dropout voltage Typical VF 1.35V (1.17V at IF=10mA) IF=50mA
Maximum 1.5V
Output On resistance Typical Ron 0.55Ω IF=10mA
IL=Max.
Within 1s
Maximum 2.0Ω
Load short circuit detection voltage*1 Typical VLSHT 5V IF=10mA
Maximum 7V
Off state leakage current Maximum ILeak 1μA IF=0mA
VL=Max.
Transfer characteristics Turn on time*2 Typical Ton 2.0ms IF=10mA
IL=100mA
VL=10V
Maximum 5.0ms
Turn off time*2 Typical Toff 0.1ms
Maximum 1.0ms
I/O capacitance Typical Ciso 0.8pF f=1MHz
VB=0V
Maximum 1.5pF
Initial I/O isolation resistance Minimum Riso 1,000MΩ 500V DC
*1. At IF=10mA, load current will be oscillated if the voltage between 4 (+) -6 (-) terminals becomes more than the delection voltage of the short circuit.
*2. Turn on/Turn off time
Turn on/Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 10 30 mA
AQV112KL(A) Load voltage (DC) VL 10 48 V
Continuous load current (DC) IL - 0.5 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)