・Operating characteristics such as "Operate voltage" and "Release voltage" are influenced by mounting conditions, ambient temperature, etc. Therefore, please use the relay within ±5% of rated coil voltage.
・"Initial" means the condition of products at the time of delivery.
Contact arrangement | Rated coil voltage | Operate voltage *1 (at 20°C) |
Release voltage *1 (at 20°C) |
Rated operating current (±10% at 20°C) |
Coil resistance (±10% at 20°C) |
Rated operating power | Max. allowable voltage *2 (at 20°C) |
|
---|---|---|---|---|---|---|---|---|
2 poles | 1 Form A 1 Form B |
3 V DC | Max. 75% of rated voltage (initial) |
Min. 10% of rated voltage (initial) |
90 mA | 33.3 Ω | 270 mW (When input) 100 mW (When retained) |
120 % V of rated voltage |
5 V DC | 54 mA | 92.6 Ω | ||||||
12 V DC | 23 mA | 533 Ω | ||||||
16 V DC | 17 mA | 948 Ω | ||||||
18 V DC | 15 mA | 1,200 Ω | ||||||
21 V DC | 13 mA | 1,633 Ω | ||||||
24 V DC | 11 mA | 2,133 Ω |
*1: Square, pulse drive
*2: It is not allowed to apply the continuous maximum voltage to the coil.
In order to obtain the specified performance, please apply the rated voltage.
Characteristics | Item | Specifications |
---|---|---|
Contact | Coil arrangement | 1 Form A 1 Form B |
Contact resistance, max (Initial) | Max. 100 mΩ (By voltage drop 6 V DC 1 A) | |
Contact material | RT Ⅱ : Au flashed AgNi type RT Ⅲ : Au flashed AgSnO2 type |
|
Contact rating (resistive) | N.O. contact (5-6 terminal); 6 A 250 V AC, 6 A 30 V DC N.C. contact (3-4 terminal); 4 A 250 V AC, 4 A 30 V DC |
|
Max. switching power (resistive) | N.O. contact (5-6 terminal); 1,500 VA, 180 W (85 W: when load voltage exceeds 30 V DC) N.C. contact (3-4 terminal); 1,000 VA, 120 W (85 W: when load voltage exceeds 30 V DC) |
|
Max. switching voltage | 250 V AC, 125 V DC | |
Max. switching current | N.O. contact (5-6 terminal): 6 A AC, 6 A DC N.C. contact (3-4 terminal): 4 A AC, 4 A DC |
|
Min. switching load (reference value)*1 | 1 mA 10 V DC | |
insulation resistance (initial) | Min. 1,000 MΩ at 500 V DC (Measured portion is the same as the case of dielectric strength.) | |
Dielectric strength (initial) | Between open contacts | 1,500 Vrms for 1 min (Detection current: 10 mA) |
Between contact and coil | N.O. contact (5-6 terminal) - coil; 4,000 Vrms for 1 min N.C. contact (3-4 terminal) - coil; 2,500 Vrms for 1 min |
|
Coil hold voltage*2 | 60% of rated voltage (-40°C to 85°C) | |
Time characteristics (initial) | Operate time | Max. 15 ms (at rated voltage, at 20°C, without bounce) |
Release time*3 | Max. 10 ms (at rated voltage, at 20°C, without bounce, without diode) | |
Shock resistance | Functional | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Destructive | 1,000 m/s2 (half-sine shock pulse: 6 ms) | |
Vibration resistance | Functional | 10 Hz to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) |
Destructive | 10 Hz to 55 Hz (at double amplitude of 3.5 mm) | |
Expected life | Mechanical life | Min. 10 x 106 ope. (at 180 times/min) |
Conditions | Conditions for usage, transport and storage*4 |
Ambient temperature: -40°C to 85°C Humidity: 5% RH to 85 % RH (Avoid icing and condensation) |
Unit weight | Approx. 6.5 g |
*1: This value can change due to the switching frequency,
environmental conditions, and desired reliability level,
therefore it is recommended to check this with the actual load.
*2: Coil holding voltage is the coil voltage after 100 ms from the application of rated coil voltage.
*3: If a diode is connected across the coil in parallel, the release time will be delayed.
Check this under actual operating conditions.
*4: For ambient temperature, please read "GUIDELINES FOR RELAY USAGE".
Condition: Resistive load, at 6 times/min (ON : OFF = 1 s : 9 s)
Type | Switching capacity | Number of operations | |
---|---|---|---|
RT Ⅱ, RT Ⅲ | N.O. contact (5-6 terminal) | 6 A 250 V AC | 100 x 103 ope. |
6 A 30 V DC | 100 x 103 ope. | ||
N.C. contact (3-4 terminal) | 4 A 250 V AC | 100 x 103 ope. | |
4 A 30 V DC | 100 x 103 ope. |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])