Item | Part No. | Remarks | ||
---|---|---|---|---|
AQAD551DL | AQAD171DL | |||
Input side | Control voltage | 4 to 32 V DC | ||
Input current | Max. 20 mA | |||
Drop-out voltage | Min. 1 V | |||
Output side | Max. load current (DC) | 30 A | 10 A | |
Peak load current | 90 A (VL = 60 V DC) | 20 A (VL = 600 V DC) | 100 ms (1 shot) | |
Max. load voltage (DC) | 100 V | 600 V | ||
“OFF-state” leakage current | Max. 100 μA | VL = Max. | ||
“ON” resistance | Max. 20 mΩ | Max. 200 mΩ | at Max. carrying current | |
Max. power dissipation | 20 W |
Item | Part No. | Condition | |
---|---|---|---|
AQAD551DL | AQAD171DL | ||
Operate time | Max. 10 ms | Max. 5 ms | VIN = 4 V, IL = 1 A, VL = 10 V Resistive load |
Release time | Max. 3 ms | Max. 1 ms | VIN = 4 V, IL = 1 A, VL = 10 V Resistive load |
Insulation resistance | 100 MΩ between input and output | at 500 V DC | |
Breakdown voltage | 4,000 Vrms between input and output 2,500 Vrms between input, output and case |
for 1 minute | |
Vibration resistance | 10 to 55 Hz double amplitude of 1.5 mm | X, Y, Z axes | |
Shock resistance | Min. 980 m/s² | X, Y, Z axes | |
Ambient temperature | − 20 to + 80℃ | Non-icing and non-condensing | |
Storage temperature | − 20 to + 85℃ | Non-icing and non-condensing | |
Max. operating frequency | 0.5 cps | VIN = 4 V, duty = 50%, IL = Max., VL = Max. |
* | Note: VIN is input voltage, IL is load current, and VL is load voltage. |
---|
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)