Ratings (Ambient temperature: 20℃, Input voltage ripple: 1% or less)

1.Zero-cross

Item Part No. Remarks
AQG12105 AQG12112 AQG12124 AQG22105 AQG22112 AQG22124
Input
side
Rated voltage 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC *1
Control voltage 4 to
6 V DC
9.6 to
14.4 V DC
19.2 to
28.8 V DC
4 to
6 V DC
9.6 to
14.4 V DC
19.2 to
28.8 V DC
Input impedance
(Approx.)
0.3 kΩ 0.8 kΩ 1.6 kΩ 0.3 kΩ 0.8 kΩ 1.6 kΩ
Drop-out voltage Min.1 V
Reverse voltage 3 V  
Load
side
Max.
load current *2
1 A 2 A 1 A:Ta = Max. 40℃
2 A:Ta = Max. 25℃
Load voltage 75 to 264 Vrms  
Frequency 45 to 65 Hz  
Non-repetitive
surge current *3
8 A 30 A In one cycle
at 60 Hz
“OFF-state”
leakage current
Max. 1.5 mA at 60 Hz
at 200 Vrms
“ON-state”
voltage drop
Max. 1.6 V at Max.
carrying current
Min.
load current *4
20 mA  

2.Random

Item Part No. Remarks
AQG12205 AQG12212 AQG12224 AQG22205 AQG22212 AQG22224
Input
side
Rated voltage 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC *1
Control voltage 4 to
6 V DC
9.6 to
14.4 V DC
19.2 to
28.8 V DC
4 to
6 V DC
9.6 to
14.4 V DC
19.2 to
28.8 V DC
Input impedance
(Approx.)
0.3 kΩ 0.8 kΩ 1.6 kΩ 0.3 kΩ 0.8 kΩ 1.6 kΩ
Drop-out voltage Min. 1 V
Reverse voltage 3 V  
Load
side
Max.
load current *2
1 A 2 A 1 A:Ta = Max. 40℃
2 A:Ta = Max. 25℃
Load voltage 75 to 264 Vrms  
Frequency 45 to 65 Hz  
Non-repetitive
surge current *3
8 A 30 A In one cycle
at 60 Hz
“OFF-state”
leakage current
Max. 1.5 mA at 60 Hz at
200 Vrms
“ON-state”
voltage drop
Max. 1.6 V at Max.
carrying current
Min.
load current *4
20 mA  
*1Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2Refer to REFERENCE DATA “1. Load current vs. ambient temperature characteristics”.
*3Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4When the load current is less than the rated minimum load current,
please refer to “Cautions for Use of Solid State Relays”.

Return to top

Characteristics (Ambient temperature: 20℃, Input voltage ripple: 1% or less)

Item type Remarks
Zero-cross Random
Operate time Max. 1/2 cycle of voltage sine wave + 1 ms Max. 1 ms  
Release time Max. 1/2 cycle of voltage sine wave + 1 ms  
Insulation resistance Min. 10 ⁹ Ω between input and output at 500 V DC
Breakdown voltage 3,000 Vrms between input and output for 1 minute
Vibration resistance 10 to 55 Hz double amplitude of 0.75 mm X, Y, Z axes
Shock resistance Min. 1,000 m/s² X, Y, Z axes
Ambient temperature − 30 to + 80℃ Non-icing and
non-condensing
Storage temperature − 30 to + 100℃ Non-icing and
non-condensing
Operational method Zero-cross (Turn-ON and Turn-OFF) Random turn ON, zero-cross turn OFF  

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)