Rating (Ambient temperature: 20℃, Ripple factor: less than 1%)

Item Part No. Remarks
AQ1298 AQ1208
Input side Control voltage 4 to 32 V DC *1
Input impedance
Input current, Max. 20 mA
Drop-out voltage Min. 1.0 V
Load side Max. load current 3 A 10 A *5 *2
Load voltage 75 to 250 Vrms
Frequency 45 to 65 Hz  
Non-repetitive surge current *3 100 A AC: In one cycle at 60 Hz
“OFF-state” leakage current Max. 5 mA AC: at 200 V, 60 Hz
“ON-state” voltage drop Max. 1.6 V At Max. carrying current
Min. load current *4 50 mA  
*1Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2Refer to REFERENCE DATA “1. Load current vs. ambient temperature characteristics”.
*3Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4When load current is below the rating, refer to “Cautions for Use of Solid State Relays”.
*5When heat sink (AQ1802) is installed. The max. load current is 5 A when heat sink is not installed.

Return to top

Characteristics (Ambient temperature: 20℃, Ripple factor: less than 1%)

Item Part No. Remarks
AQ1298 / AQ1208
Operate time Max. 1/2 cycle of voltage sine wave + 1 ms  
Release time Max. 1/2 cycle of voltage sine wave + 1 ms  
Insulation resistance Min. 100 MΩ between input, output and case at 500 V DC
Breakdown voltage 4,000 Vrms between input and output
2,500 Vrms between input, output and case
For 1 minute
Vibration
resistance
Destructive 10 to 55 Hz at double amplitude of 2 mm 1 hour for X, Y, Z axis
Functional 10 to 55 Hz at double amplitude of 2 mm 10 minutes for X, Y, Z axis
Shock
resistance
Destructive Min. 980 m/s² 5 times each for X, Y, Z axis
Functional Min. 980 m/s² 4 times each for X, Y, Z axis
Ambient temperature − 30 to +80℃ Non-icing and non-condensing
Storage temperature − 30 to +100℃ Non-icing and non-condensing
Operational method Zero-cross (Turn-ON and Turn-OFF)  

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)